Please read these instructions
carefully before using your new
Royal Vacuum Cleaner.
Let us help you put your
cleaner together or answer
any questions, call:
1-800-321 -1 134
www.royalappliance.com
For quick reference, please record your
vacuum information below.
Model Number
Manufacture Code
(USA &
Canada)
WARNING:
Cleaner assembly may include
A
Espaiiol - pagina El
small parts. Small parts can
present
a
choking hazard.
Manufacture code
02003
All rights reserved #
is
located
on
the lower backside of vacuum.
1-1 13440-000
1 0103
FOR COMMERCIAL
USE
ONLY
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed, including the
following:
READ ALL INSTRUCTIONS BEFORE USING
WARNING - To reduce the risk of fire, electric shock, or injury: Electric shock could occur if
used outdoors or on wet surfaces.
Do not leave appliance when plugged in. Unplug from outlet when not in use and before servicing.
Never allow children or untrained adults to operate this equipment.
Keep the area of operation clear of all persons, particularly small children, and pets. Keep bystanders
25
at least
Use only as described in this manual. Use only manufacturer's recommended attachments.
Do not use with damaged cord or plug. If appliance is not working as it should, as been dropped,
damaged, left outdoors, or dropped into water, return it to a service center.
Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp
edges or corners. Do not run appliance over cord. Keep cord away from heated surfaces.
Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
Do not handle plug or appliance with wet hands.
Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint,
hair, and anything that may reduce air flow.
Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
Do not use without dustbag andlor filters in place.
Turn off all controls before unplugging.
Use extra care when cleaning on stairs.
Do not use to pick up flammable or combustible liquids such as gasoline or use in areas they may
be present.
Connect to a properly grounded outlet only. See grounding instructions.
This appliance is not suitable for removal of dusts that are dangerous to health.
This appliance is suitable only for dry cleaning and must not be used out doors.
The power cord should be inspected regularly for signs of damage. Do not use if the cord is
damaged.
feet away from the area of operation.
SAVE THESE INSTRUCTIONS
INSPECTION
Carefully unpack and inspect your machine for shipping damage. Each unit is tested and thoroughly
inspected before shipment, and any damage is the responsibility of the delivery carrier who should
be notified immediately.
USER MAINTENANCE INSTRUCTIONS
All service and repair should be performed by qualified service representative or electrician.
user serviceable components are employed in the electrical system. No lubrication of the motor is
required.
While not in use storage can be accomplished by winding cord around rear of machine. Cord hooks
are provided.
This equipment should be stored indoors and not exposed to rain.
No
ELECTRICAL - Model MRY5500
This machine is designed to operate on a standard 15 amp. 120 volt, 60 hz, AC circuit. Voltages
below 105 volts
AC or above 125 volts AC could cause serious damage to the motor.
WARNING
Electric motors can cause explosions when operated near explosive materials or vapors. Do not
operate this machine near flammable materials such as solvents, thinners, fuels, grain dust, etc.
GROUNDING INSTRUCTIONS (120V only)
This appliance must be grounded. If it should malfunction or breakdown, grounding provides a path
of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped
with a cord having an equipment-grounding conductor and grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and grounded in accordance with all local codes
and ordinances.
DANGER
electric shock. Check with a qualified electrician or service person if you are in doubt as to whether
the outlet is properly grounded. Do not modify the plug provided with the appliance
the outlet, have a proper outlet installed by a qualified electrician.
This appliance is for use on a nominal 120-volt circuit and has a grounding plug that looks like the
plug illustrated in
same configuration as the plug. No adapter should be used with this appliance.
-
Improper connection of the equipment-grounding conductor can result in a risk of
-
if it will not fit
sketchA below. Make sure that the appliance is connected to an outlet having the
GROUNDING PIN
1.
lnstallationlRemoval of Nozzle Base
Nozzle base can be removed by turning knob to the right. The nozzle base can now be separated
from vacuum housing.
2.
Handle Release
To release the machine from upright position, push down on foot release as shown in example
3.
Brush Adjustment
Brush adjustment is made by rotating knob
(3)
1 Electronic Control (Figure
(3)
I)
to desired position. Always start at the highest
setting and rotate to lower setting if needed (see explanation below). The two indicator lights on
the nozzle base allows the operator to monitor brush performance. When only the GREEN LIGHT
is on, brush setting is correct. When both the GREEN and RED LIGHTS are on, the brush setting
is too high. Lower brush setting until the RED LIGHT goes out.
RED LIGHT may flicker when used on low nap commercial grade glue down type carpet. If RED
LIGHT remains on continuously during brush operation at lowest setting
(I),
brush strip should be
replaced. If brush assembly is obstructed, electronic control will shut off brush motor. Turn machine
off and UNPLUG from ELECTRICAL OUTLET. Clear obstruction from brush assembly and restart.
4.
Bristle Insert Replacement
Remove cover and pull brush strip out. lnsert new brush strip and push it in all the way. Replace
cover. CAUTION: Unplug unit from electrical outlet.
2.
I.
Tool Storage
Tools should be installed as shown in Figure
snapped into the retainers.
2.
Accessory Hose (Figure
The vacuum hose can be used for direct suction use or with accessory tools. Simply pull out from
base to use. NOTE: The brush motor turns off when the hose is removed from the housing.
3.
Full Bag lndicator
The indicator light will illuminate when the collection bag is full or when there is a blockage in the
hose or nozzle base. lndicator light is next to onloff switch.
Description
Clamp Plastic 5/16 3305
Wand Upright
Upright Handle (ORG)
Housing Release Knob
Cord Strain Relief
Hose Lock Fitting
Hose Lock Ring
Upright Vacuum Hose
VAC Motor Gasket
VAC Motor Dampener
Crevice Tool
Strain Relief Housing (ORG)
Handle Cover Cap (ORG)
Housing, Upper Front (ORG)
Housing, VAC Motor (ORG)
Filter, Door Assy (ORG)
Coupling, Hose (ORG)
Latch Bag Clip (ORG)
Cover, Bag Latch (ORG)
Button, Filter Cover (ORG)
CAM, Lock and Release
Cover, VAC Motor
Wire Form, Lock-Release
Spring, Cover Button
Spring, Bag Latch
Handle Patriot Transport (ORG)
Lense-Bag Full Light
Cover, Latch (ORG)
Filter Frame, VAC Motor
Tab, Hold Down
Latch (ORG)
Cover, Electronics (ORG)
Spring, Cord Hook
Accessory Clip
Spring Bag Cover Latch
Extruded Handle
311 6 X 318 CCF
Gasket
Vacuum Bag PFG 10
Nut-Riv
Backer Plate
Decal Base Release NS
Housing Rear Cover (ORG)
Decal Patriot New Style
SCR-MC 10-32.37 NI PL
Hospital Filter Pkg of 10
SCR-MC 8-32X.62 ST PL
Thermodisc 290TWIN
SCR-MC 10-32X1.25 ST PL
VAC MTR 6378-07 120V
SCR-ST-B 10X.37 NI
Power Cord Upright
SCR HI-LO
Switch 21 2FGOB1 ODOS
SCR-ST-B HI-LO 8x50 PL
Terminal, Screw
Nut-NLOC 8-32
PC Board
Receptacle AC Power
Wire Assembly Gounding
Wire Assembly
Wire Harness, Patriot NS
Rivet Pop
Cord Hook
WSH-.22
SCR-MC 10-32x50 ST PL
WSR-Flat
Decal Caution INS
Decal Insert Hose
SCR-TR HD %-20 X .50
Decal Warning
Decal Bag Install
Strain Relief
Carbon Brush Replacement
Gasket
Gasket, Motor Cover
Brush Assy Complete
Brush End PlatelDrive
Brush Drive Pulley
Belt Brush DN
128XL025
Motor Drive Pulley
Upright Brush Motor
Carbon Brush Replacements
Upright Brush & Strip Assy
Brush Strip Door
Brush End Platelldle
Bearing Upright Brush
Electronic Control
Circuit Board Cushion
SCR-ST-B Hi-Lo
18"
8x50
3
PL
Spring Front Axle
Vacuum Head Cam
Brush Baselupright
Rub Strip
Term Block
PA-27-2
Strain Relief Cover
Support, Side Arm
Upright Foot Release
Upright Rear Axle
Spring-Upright Axle
Wheel
2
in. Molded
Hubcap Upright
Plate-Axle Retainer
Brush-Metal Protector
Wire Formed Protector
Center Wheel
I
.5
Molded
Center Wheel Axle
Bumper Molded
SCR-MC
SCR-MC
SCR-MC
10-32 x 1.25
8-32 x .62
6-32 x .37
ST NI
OH
ST PL
Pushnut Bolt Retainer
WSR-Flat
#8
Coupling Bearing Bush
WSR-Flat
114
ID
SS
Straight Knurled Pin
Decal Caution Brush Star
WSR-Wave
.37 X .68 X .08
Decal, Royal Commercial
120V
WIRING
STATIC PIN
GROUND
DIAGRAM
120
VAC
he-
TERMINAL
BLOCK
VACUUM
SENSOR
L
-,------
ELECTRONIC
BOARD
-I
TEMPERATURE
SWITCH
-6
MOTOR
::$&
ELECTRONIC
BOARD
I
MOTOR
To the consumer, Royal Appliance Mfg. Co. warrants this vacuum cleaner to be free of defects in material or workmanship
I
year from the date of the original purchase. Save your original sales receipt to validate start of warranty period. If the
for
vacuum cleaner should become defective within the warranty period, we will repair or replace any defective parts free of
&
charge. The complete machine must be delivered prepaid to any ROYAL@ Authorized Sales
Station. Please include complete description of the problem, day of purchase, copy of original sales receipt and your
name, address and telephone number. If you are not near a Warranty Station, call the factory for assistance at USA&
Canada:
place this product in correct operating condition and does not cover any other damages including consequential damages.
This warranty does not apply to damage or malfunction caused by misabuse, abuse, negligence, accident, or damage
due to transport. This warranty does not cover brushes, flat belts, filters, bulbs. This warranty does not cover unauthorized
repairs. This warranty gives you specific legal rights and you may also have other rights. (Other rights may vary from
state to state in the USA.
1-800-321-1134.
Use only genuine Royal@ replacement parts. This warranty covers only labor and parts to
Warranty Service
Royal Appliance
7005
Cochran
Rd.
Glenwillow, OH
Mfg.
441
39
Co.
987946EN
Printed in U.S.A.
Loading...
+ 25 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.