Direct Supply Panacea 1750, 2000 Owner's Manual

Direct Supply® Panacea® 1750 & 2000 Adjustable-Height Low Bed
Owner’s Manual
Thank you for purchasing a Direct Supply® Panacea® 1750/2000 Adjustable-Height Low Bed from Direct Supply Equipment & Furnishings®. Please read this entire guide carefully and keep it for future reference. This guide will provide you with instructions, warnings, warranty information and other important information about your Direct Supply Panacea bed. Share this information with your housekeeping, nursing and maintenance staff to help ensure the bed is cared for properly.
Please keep and refer to this Owner’s Manual.
1-800-634-7328 ■ DirectSupply.com
Introduction
Table of Contents
Warnings ......................................................... 3-5
Environmental and Electrical Specifications .. 6
Locating Your Serial Number ....................... 6
Directions for Use ......................................... 7-14
Unpacking ....................................................... 7
Foot Panel Installation ................................... 8
Installation of Baseboard Bumper ................ 9
Installation of Mattress Stop ....................... 10
I.V. Sockets ................................................... 11
Installation of Staff Control Panel .............. 12
Bed Positioning ............................................ 13
Setting Space Saving Angle (4°) Mode ..... 14
Bed Transport ............................................. 15-19
Standard Roll at Any Height Feature ......... 15
Safety Lock Feature (optional) .................... 16
Panacea 2000 .............................................. 17-18
Expandable Sleep Surface .......................... 17
Panacea 2000 Manual Vascular
Leg Lift Operation ........................................ 18
Accessories and Options ................................ 18
Optional Battery ........................................... 18
Servicing ...................................................... 19-21
Troubleshooting ...................................... 19-20
Steps for Isolating Electrical Problems ...... 21
Cleaning ............................................................ 22
Cleaning Method .......................................... 22
Cleaning Instructions ................................... 22
Periodic Inspection .......................................... 22
Limited Warranty ............................................ 23
Customer Service ............................................ 24
Definitions and Symbols
NOTE: Indicates a tip.
CAUTION: Indicates correct operating or maintenance procedures in order to prevent damage to or
destruction of the equipment or other property.
WARNING: Calls attention to a potential danger that requires correct procedures or practices in order to prevent personal injury.
DEVICE: Direct Supply® Panacea® 1750 or 2000 Bed.
YOU and YOUR: The facility, community or other entity that has purchased the device.
WE, US and OUR: Direct Supply Manufacturing, Inc.
Attention. Consult accompanying drawings.
2
Please keep and refer to this Owner’s Manual.
Warnings
WARNING: Possible Injury Or Death. This product is intended for use as an adjustable mattress
platform that contours for resident/patient comfort with adjustable height for resident/patient and caregiver convenience. Use of this product in a manner for which it was not designed could result in unproven or unsafe configuration, potentially resulting in injury or death.
WARNING: Possible Injury. Before adjusting bed, ensure that area under and near bed perimeter is
free of people and obstructions. Failure to do so could result in injury or damage to the bed.
WARNING: Possible Injury. Keep bed in lowest position except when providing care (bathing,
clothing changes, etc.). Bed should be at lowest convenient height for entry or exit. Failure to do so could result in injury.
WARNING: Possible Injury Or Death. Resident/ patients may become entangled in pendant cord.
Resident/patients with reduced mental acuity should not be allowed access to pendant. Unsupervised use of pendant could result in injury or death.
WARNING: Possible Injury Or Death. Bed safe working load is 500 pounds. This is total weight
counting resident/patient, mattress, bedding accessories and any other equipment or persons likely to be on bed. Do not exceed 500-pound safe working load. Exceeding the safe working load could result in property damage, injury or death.
WARNING: Possible Injury Or Death. Do not roll bed over abrupt thresholds with resident/patient
in bed. Bed is not designed for transporting resident/patient. Transporting resident/patient in the bed could result in injury or death.
WARNING: Possible fire hazard when used with oxygen administrating equipment other than nasal,
mask or ½ bed length tent type. Not for use with full bed length tent or hyperbaric oxygen chamber. Oxygen tent should not extend below mattress support platform. Lock hand control at foot of bed when using oxygen administering equipment.
WARNING: Possible Shock Hazard. Unplug power cord from wall outlet before performing any
maintenance, cleaning or service to the bed. Failure to do so could result in injury or death. Note: In case of unexpected movement, unplug bed from any outlet.
WARNING: Possible Shock Hazard. Injury may result from improper routing of the power cord.
Always follow the proper factory-installed routing configuration. Failure to do so could result in injury or death.
WARNING: Possible Injury Or Death. Use a mattress that is properly sized to fit mattress deck,
that will remain centered on mattress deck relative to State and Federal guidelines. Direct Supply recommends the use of a mattress with minimum dimensions of 35 inches wide and 6 inches deep. Length should match mattress support platform. Use of an improperly fitted mattress could result in injury or death. If using the optional width extension kit, or the bed is equipped with the integrated width expansion, Direct Supply recommends the use of a mattress with a minimum width of 39 inches for a 39 inch setting and 42 inches for 42 inch setting.
1-800-634-7328
DirectSupply.com 3
Warnings (cont.)
WARNING: Possible Injury Or Death. If a resident/patient’s mental or physical condition could lead
to resident/patient entrapment, the mattress support platform should be left in the flat position when unattended. Failure to do so could result in injury or death.
WARNING: An optimal bed system assessment should be conducted on each resident by a
qualified clinician or medical provider to ensure maximum safety of the resident. The assessment should be conducted within the context of, and in compliance with, the state and federal guidelines related to the use of restraints and bed system entrapment guidance, including the Clinical Guidance for the Assessment and Implementation of Side Rails published by the Hospital Bed Safety Workgroup of the U.S. Food and Drug Administration. Further information can be obtained at the following web address: http://www.fda.gov/MedicalDevices/ProductsandMedicalProcedures/ GeneralHospitalDevicesandSupplies/HospitalBeds/default.htm.
WARNING: Possible Injury Or Death. Use a properly sized mattress in order to minimize the gap
between the side of mattress and assist device. This gap must be small enough to prevent resident/ patient from getting his/her head or neck caught in this location. Make sure that raising or lowering bed, or contouring the sleep surface, does not create any hazardous gaps. Excessive gaps may result in injury or death.
WARNING: Possible Injury Or Death. Locate mounting brackets for assist devices strictly according
to instructions. Gap between head/foot panel and assist device must be small enough or large enough to prevent resident/patient from getting his/her head or neck caught in this location (see specific Assist Device Installation Instructions for more information). If multiple assist devices are used, position each so that gap between them is large enough for trunk and hips to pass through easily. Make sure raising or lowering bed, or contouring sleep surface does not create any hazardous gaps. Failure to do so could result in injury or death. Important Note: Powered air mattress surfaces may pose a risk of entrapment. Prior to use, ensure the therapeutic benefits outweigh the risk of entrapment.
WARNING: Possible Injury Or Death. Do not use an assist device if any openings within assist
device body allow resident/patient to get his/her head or neck lodged within these openings. Use of assist devices with large openings may result in injury or death.
WARNING: Possible Injury Or Death. Do not use any Panacea
designed specifically for you Panacea® bed and it is locked in place. Failure to lock assist devices may result in injury or death.
WARNING: Possible Injury Or Death. Do not use any replacement parts not manufactured,
marketed or provided by Direct Supply Panacea on any Direct Supply Panacea bed. Use of unapproved replacement parts may result in injury or death.
WARNING: Possible Injury Or Death. If using accessories not manufactured, marketed or provided
by Direct Supply Panacea for Direct Supply Panacea beds, consult with the manufacturer for compatibility and limitations prior to use. Failure to do so may result in injury or death.
WARNING: Possible Shock Hazard. If the bed power cord has a hospital-grade, 3-prong grounding
plug, grounding reliability can only be achieved when equipment is connected to an equivalent receptacle marked hospital-grade.
4
®
assist device until you verify it is
WARNING: Possible Injury. Sitting on or sliding over the Mattress Side Stop can cause skin injury if
the bed mattress compresses to less than 1.5 inches under user’s weight.
WARNING: Possible Injury. Risk of entanglement or injury may occur if mattress used with Mattress
Side Stop does not fill the entire width between stops or which compresses to less than 1.5 inches under user’s weight.
WARNING: Possible Injury or Death. Floor locks increase bed stability and resident safety. Make
sure the bed is in a locked position with respect to the floor by ensuring the casters are off the floor or if equipped, the safety lock is in the locked position before attempting any resident transfers. Failure to do so could result in injury or death.
WARNING: Possible Injury. Use caution when activating the safety lock function. This feature was
designed to be activated by your foot. Using your hand to activate the safety lock system could result in injury.
CAUTION: In the absence of line voltage, all bed adjustments can be achieved via an externally
available backup battery. Direct Supply recommends a minimum of one battery for every twenty five beds per facility.
CAUTION: This device complies with EMC requirements of IEC 60601-1-2. Radio transmitting
equipment, cellular phones or similar electronic devices, used in proximity of bed, may affect bed performance.
CAUTION: Particular precaution must be considered during exposure to strong emission sources
such as High Frequency surgical equipment and similar devices. Do not route High Frequency cables on or near device. If in doubt, contact a qualified technician.
CAUTION: Your Panacea bed is intended for use within an institutional healthcare environment (ie:
skilled nursing, transitional care, rehabilitational care, assisted living). Direct Supply recommends compliance to the regulations and guidelines specified to your locality.
This product is only one part of your healthcare bed system. Proper combinations of mattress, head/ foot panels and assist devices are needed to minimize the risk of entrapment. For more information, call Direct Supply, 800-634-7328.
1-800-634-7328
DirectSupply.com 5
Environmental and Electrical Specifications
Standard Features
80" Mattress Support Platform
81⁄4" to 27" Travel
Quiet DC Actuators
Welded Tubular Frame
Grid Sleep Surface
Wide Stable Base
Baseboard Bumper
Heavy-Duty Casters
Mattress Stops
Electrical Specifications
Power: 120V
Frequency: 60 Hz
Current Rating: 2.0 Amps
Classification: Class I, Type B
Mode of Operation: 10% Maximum Duty Cycle
2 minutes on/18 minutes off
Circuit Protection: Auto reset current sensors
I.D. Label Symbol Definition
Attention, Consult Accompanying Documents
Safe Working Load
Environmental Conditions
Operating Conditions:
Ambient Temperature: +50°F to +104°F
Relative Humidity:
Atmospheric Pressure: 700 hPa to 1060 hPa
Protected Against Splashing Water IPX4
Storage and Shipping Conditions:
Ambient Temperature: -40°F to +158°F
Relative Humidity: 10% to 100%
Atmospheric Pressure: 500 hPa to 1060 hPa
30% to 75% Non-Condensing
Mechanical Specifications
Description: Dimensions:
80" Model 841⁄4"L x 35"W x 81⁄4"H
Standard: 200 lbs.
Weight
Maximum Back Angle 65° to horizontal
Maximum Knee Angle 35° to horizontal
Maximum Knee to Leg Angle 45°
Maximum Height Mattress Support Platform
Minimum Height Mattress Support Platform
Safe Working Load 500 lbs.
w/ Safety Lock: 210 lbs.
w/ Width Kit: Adds 40 lbs.
27" Above Floor
81⁄4" Above Floor
Type B Applied Parts
Class II Equipment
Protective Earth (ground)
Locating Your Product ID Label and Serial Number
The product ID label (pictured below) is located at the foot end of the bed frame, under the mattress support deck. The serial number is located on an additional label, next to the product ID label.
6
Directions for Use
Unpacking
NOTE: Unpack the bed in an area with sufficient room to work. Do not allow residents near the
bed until it has been completely set up and the work area has been cleared of all debris.
1. Inspect the bed for shipping damage. If the bed is damaged, DO NOT USE BED and
immediately contact Direct Supply Equipment & Furnishings® for further instruction.
2. Verify the proper bed model and size was shipped. If you feel there was a mistake,
DO NOT USE BED and immediately contact Direct Supply Equipment & Furnishings.
3. Carefully remove the orange packaging zip ties before operating the bed.
Assembly
Installation Of Head and Foot Panels
Tools Required: #2 Phillips Screwdriver
Head Panel Installation:
1. Locate the head panel; the head panel has a label on the back.
2. Lay panel on a flat soft surface, face down – threaded t-nuts facing away from the bed occupant.
3. Head panel brackets have rubber bumpers mounted on them.
4. The panel brackets are right-left oriented. Items welded to the side of the panel mounting tube should be placed to the inside (Figure 1). Install head panel brackets with four screws provided. Do not tighten at this time.
5. Insert the brackets into the bed frame sockets (Figure 2); maintain support of the bed panel. Insert the safety pins on each side and latch them (Figure 3).
6. Press the mounting bracket against the bed frame and tighten the mounting screws; right and left side.
Figure 1
Figure 2
Figure 3
1-800-634-7328
DirectSupply.com 7
Directions for Use (cont.)
Foot Panel Installation:
1. Locate the Foot Panel; the foot panel does not have a label on the back.
2. Lay panel on a flat soft surface - face down – threaded t-nuts facing towards the bed occupant.
3. The panel brackets are right-left oriented. Items welded to the side of the panel mounting tube should be placed to the inside (Figure 4). Install foot panel brackets with four screws provided. Do not tighten at this time.
4. Insert the brackets into the bed sockets (Figure 5); maintain support of the bed panel. Insert the safety pins on each side and latch them (Figure 6).
5. Press the mounting bracket against the bed frame and tighten the mounting screws; right and left side.
Figure 4 Figure 5
Figure 6
8
Loading...