© 2007 Directed Electronics—all rights reserved
25
Menu #3 – Installer features
3-1 NUISANCE PREVENTION® CIRCUITRY (NPC®) ON/OFF: These settings control the number of times a sensor
can trigger the system within a given time period.
•NPCON (Default): In this setting any source (sensor or trunk switch) that triggers more than 3 times
within 1 hour period will be bypassed for a minimum of 1 hour. If within that 1 hour the systems see’s
the same source (sensor or trunk switch) trigger again it will not activate the siren/horn and will restart
the 1 hour timer.
NOTE: Door switches and the ignition switch are exempt to the description above.
•NPCOFF:Inthissettingthesensorswilltriggerrepeatedlyuntilthesystemisdisarmed.
3-2 ARM FUNCTION OFF-ARM ONLY/ (Grouped MULTI-LEVEL ARMING/PANIC/AUX CH): These settings
change the system ability to activate multi-level arming, panic or auxiliary channel while pressing the
Lock button.
•WhensetARMONLY,thesystemwillbere-armedatsuccessivepressesonlockbutton.
•WhensetPANIC,thesystemwillswitchonpanicfunctionwhiletheuserpresslockbuttonforthesecond
time. Panic will cease when arming/disarming with original remote.
•When programmed on AUXCH, the system will activate the auxiliarychannel when pressing the Lock
button for the second time.
•WhenprogrammedonMulti-levelArming,thesystemwillactivatetheMulti-levelArmingfunctionwhen
pressing the Lock button for the second time.
NOTE: The second press must be between 3 to 7 seconds from first press.
Grouped multi-level arming
After arming, press the LOCK button again. The parking lights or turn signal will flash 3 times, the siren/
horn will chirp 3 times and all sensor warn-away and full alarm zones will be bypassed. All remaining zones
are still active (door, hood, trunk, and ignition).
Aux channel
After arming, press the LOCK button again. The security system will activate the auxiliary output (N1/3)
and will start bypass all sensor zones for 30 seconds. During the first 3 seconds the security system will
monitor the trunk status and/or N1/8 Blue/White– (-) Status input: If either input is active, the security
system will bypass all sensors and the trunk when open, and flash the parking lights. After the trunk is
closed the sensors will be bypassed for another 20 seconds.
WARNING! If the AUX CHANNEL option is used for Remote Start activation the following must be taken
into consideration:
- The Remote start status output of the remote start module has to be connected to the
N1/8 Blue/White - (-) Status input in order for ignition and sensors to be bypassed during remote start.