![](/html/c3/c39f/c39f384ccc043459c6550e01c7e232ff3b2c11fcdea4744d10223882bb9e708c/bg1.png)
BZW 06-5V8 ... BZW 06-376
BZW 06-5V8B ... BZW 06-376B
Diotec
Unidirectional and bidirectional Unidirektionale und bidirektionale
Transient Voltage Suppressor Diodes Spannungs-Begrenzer-Dioden
Peak pulse power dissipation 600 W
Impuls-Verlustleistung
±0.05
Ø 3
Nominal breakdown voltage 5.8...376 V
Nenn-Arbeitsspannung
Plastic case – Kunststoffgehäuse DO-15 (DO-204AC)
Ø 0.8
+0.05
Weight approx. – Gewicht ca. 0.4 g
Plastic material has UL classification 94V-0
Gehäusematerial UL94V-0 klassifiziert
Standard packaging taped in ammo pack see page 17
Dimensions / Maße in mm Standard Lieferform gegurtet in Ammo-Pack siehe Seite 17
For bidirectional types use suffix “B” Suffix “B” für bidirektionale Typen
Maximum ratings Grenzwerte
Peak pulse power dissipation (10/1000 µs waveform) T = 25 °C P 600 W )
A PPM
Impuls-Verlustleistung (Strom-Impuls 10/1000 µs)
Steady state power dissipation T = 25 °C P 5 W )
A M(AV)
Verlustleistung im Dauerbetrieb
Peak forward surge current, 60 Hz half sine-wave T = 25°C I 100 A )
A FSM
Stoßstrom für eine 60 Hz Sinus-Halbwelle
1
2
3
Operating junction temperature – Sperrschichttemperatur T – 50…+175°C
Storage temperature – Lagerungstemperatur T – 50…+175°C
j
S
Characteristics Kennwerte
Max. instantaneous forward voltage I = 50 A V 200 V V < 3.0 V )
Augenblickswert der Durchlaßspannung V > 200 V V < 6.5 V )
Thermal resistance junction to ambient air R < 45 K/W )
F BR F
BR F
thA
Wärmewiderstand Sperrschicht – umgebende Luft
1
) Non-repetitive current pulse see curve I = f (t )
Höchstzulässiger Spitzenwert eines einmaligen Strom-Impulses, siehe Kurve I = f (t )
2
) Valid, if leads are kept at ambient temperature at a distance of 10 mm from case
Gültig, wenn die Anschlußdrähte in 10 mm Abstand von Gehäuse auf Umgebungstemperatur gehalten werden
3
) Unidirectional diodes only – nur für unidirektionale Dioden
01.01.99
PPM r
PPM r
159
3
3
2
![](/html/c3/c39f/c39f384ccc043459c6550e01c7e232ff3b2c11fcdea4744d10223882bb9e708c/bg2.png)
BZW 06-5V8 ... BZW 06-376
Diotec
BZW 06-5V8B ... BZW 06-376B
Maximum ratings Grenzwerte
Max. stand-off voltage Max. clamping voltage at
Type
Typ
BZW06-5V8 5.8 1000 6.8 ± 5% 6.45...7.14 *) 10.5 57
BZW06-6V4 6.4 500 7.5 ± 5% 7.13...7.88 *) 11.3 53
BZW06-7V0 7.02 200 8.2 ± 5% 7.79...8.61 *) 12.1 50
BZW06-7V8 7.78 50 9.1 ± 5% 8.65...9.55 13.4 45
BZW06-8V5 8.55 10 10 ± 5% 9.5...10.5 14.5 41
BZW06-9V4 9.4 5 11 ± 5% 10.5...11.6 15.6 38
BZW06-10 10.2 5 12 ± 5% 11.4...12.6 16.7 36
BZW06-11 11.1 5 13 ± 5% 12.4...13.7 18.2 33
BZW06-13 12.8 5 15 ± 5% 14.3...15.8 21.2 28
BZW06-14 13.6 5 16 ± 5% 15.2...16.8 22.5 27
BZW06-15 15.3 5 18 ± 5% 17.1...18.9 25.2 24
BZW06-17 17.1 5 20 ± 5% 19.0...21.0 27.7 22
BZW06-19 18.8 5 22 ± 5% 20.9...23.1 30.6 20
BZW06-20 20.5 5 24 ± 5% 22.8...25.2 33.2 18
BZW06-23 23.1 5 27 ± 5% 25.7...28.4 37.5 16
BZW06-26 25,6 5 30 ± 5% 28.5...31.5 41.5 14.5
BZW06-28 28.2 5 33 ± 5% 31.4...34.7 45.7 13.1
BZW06-31 30.8 5 36 ± 5% 34.2...37.8 49.9 12.0
BZW06-33 33.3 5 39 ± 5% 37.1...41.0 53.9 11.1
BZW06-37 36.8 5 43 ± 5% 40.9...45.2 59.3 10.1
BZW06-40 40.2 5 47 ± 5% 44.7...49.4 64.8 9.3
BZW06-44 43.6 5 51 ± 5% 48.5...53.6 70.1 8.6
BZW06-48 47.8 5 56 ± 5% 53.2...58.8 77.0 7.8
BZW06-53 53.0 5 62 ± 5% 58.9...65.1 85.0 7.1
BZW06-58 58.1 5 68 ± 5% 64.6...71.4 92.0 6.5
BZW06-64 64.1 5 75 ± 5% 71.3...78.8 103 5.8
BZW06-70 70.1 5 82 ± 5% 77.9...86.1 113 5.3
BZW06-78 77.8 5 91 ± 5% 86.5...95.5 125 4.8
BZW06-85 85.8 5 100 ± 5% 95.0...105 137 4.4
BZW06-94 94.0 5 110 ± 5% 105...116 152 3.9
BZW06-102 102 5 120 ± 5% 114...126 165 3.6
BZW06-111 111 5 130 ± 5% 124...137 179 3.4
BZW06-128 128 5 150 ± 5% 143...158 207 2.9
BZW06-136 136 5 160 ± 5% 152...168 219 2.7
BZW06-145 145 5 170 ± 5% 162...179 234 2.6
BZW06-154 154 5 180 ± 5% 171...189 246 2.4
BZW06-171 171 5 200 ± 5% 190...210 274 2.2
BZW06-188 188 5 220 ± 5% 209...231 301 2.0
BZW06-213 213 5 250 ± 5% 237...263 344 1.8
BZW06-239 239 5 280 ± 5% 266...294 384 1.7
BZW06-256 256 5 300 ± 5% 285...315 414 1.6
BZW06-273 273 5 320 ± 5% 304...336 438 1.6
BZW06-299 299 5 350 ± 5% 332...368 482 1.6
BZW06-342 342 5 400 ± 5% 380...420 548 1.3
BZW06-376 376 5 440 ± 5% 418...462 603 1.3
at leakage current 10/1000µs-pulse current
Max. Sperrspannung Max. Begrenzerspannung
bei Sperrstrom bei 10/1000µs-Stromimp.
V [V] I [µA] V [V] V [V] I [A]
WM D BR C PPM
Breakdown voltage at I = 1 mA
Arbeitsspannung bei I = 1 mA
*) tested at / gemessen bei 10 mA
T
T
160