Diodes SBR40U100CTE User Manual

Page 1
g
A
Features
Ultra Low Forward Voltage Drop
Excellent High Temperature Stability
Patented Super Barrier Rectifier Technology
Soft, Fast Switching Capability
150ºC Operating Junction Temperature
Lead Free Finish, RoHS Compliant (Note 1)
Also Available in Green Molding Compound (Note 2)
Top View Bottom View
TO262
SBR40U100CTE
SUPER BARRIER RECTIFIER
Mechanical Data
Case: TO262
Case Material: Molded Plastic, UL Flammability Classification
Rating 94V-0
Terminals: Matte Tin Finish annealed over Copper leadframe. Solderable per MIL-STD-202, Method 208
Weight: 1.355 grams (approximate)
2
Common
1
Anode
Cathode
Package Pin Out
Confi
3
Anode
uration
40A SBR
®
Ordering Information (Notes 2 & 3)
Part Number Case Packaging
SBR40U100CTE TO262 50 pieces/tube
SBR40U100CTE-G TO262 50 pieces/tube
Notes: 1. EU Directive 2002/95/EC (RoHS). All applicable RoHS exemptions applied, see EU Directive 2002/95/EC Annex Notes.
2. For Green Molding Compound version part numbers, add "-G" suffix to part number above. Examples: SBR40U100CTE-G.
3. For packaging details, go to our website at http://www.diodes.com.
Marking Information
SBR40U100CTE
Document number: DS31459 Rev. 4 - 2
SBR
40U100CTE
YYWW AB
SBR40U100CTE = Product Type Marking Code
B = Foundry and Assembly Code YYWW = Date Code Marking YY = Last two digits of year (ex: 08 = 2008) WW = Week (01 - 53)
1 of 4
www.diodes.com
November 2011
© Diodes Incorporated
Page 2
θ
Maximum Ratings (Per Leg) @T
= 25°C unless otherwise specified
A
Single phase, half wave, 60Hz, resistive or inductive load. For capacitance load, derate current by 20%.
Characteristic Symbol Value Unit
Peak Repetitive Reverse Voltage Working Peak Reverse Voltage DC Blocking Voltage
Average Rectified Output Current (Per Leg) (Total) Non-Repetitive Peak Forward Surge Current 8.3ms Single Half Sine-Wave Superimposed on Rated Load
Thermal Characteristics (Per Leg) @T
= 25°C unless otherwise specified
A
Characteristic Symbol Value Unit
Typical Thermal Resistance Junction to Case (per leg) (Note 4) Operating and Storage Temperature Range
T
J
V V
VRM
I
R
, T
RRM RWM
I
O
FSM
JC
STG
SBR40U100CTE
100 V
20 40
240 A
3 ºC/W
-65 to +150 ºC
A
Electrical Characteristics (Per Leg) @T
= 25°C unless otherwise specified
A
Characteristic Symbol Min Typ Max Unit Test Condition
Forward Voltage Drop (per leg)
Leakage Current (Note 5)
Notes: 4. Using heatsink (by Black Aluminum, 45mm x 20mm x 12mm).
5. Short duration pulse test used to minimize self-heating effect.
V
F
I
R
T = 150°C
A
T = 125°C
A
T = 85°C
A
T = 25°C
A
-
0.72
-
- -
0.78
0.67
0.5 40
V
mA
= 20A, TJ = 25ºC
I
F
I
= 20A, TJ = 125ºC
F
= 100V, TJ = 25ºC
V
R
= 100V, TJ = 125ºC
V
R
T = 150°C
A
T = 125°C
A
T = 85°C
A
T = 25°C
A
020406080100
SBR40U100CTE
Document number: DS31459 Rev. 4 - 2
2 of 4
www.diodes.com
November 2011
© Diodes Incorporated
Page 3
R
G
O
RWARD C
U
R
R
T
A
SBR40U100CTE
(A) EN
40
35
30
R = R
θθ
JA JC
Total Device
25
20
E F
15
A
10
5
F(AV),
I AVE
R = 14°C/W
JA
θ
Per Element
Note 4
R = R
θθ
JA JC
Per Element
0
25 50 75 100 125 150
T , AMBIENT TEMPERATURE ( C)
A
175
°
Fig. 3 Forward Current Derating Curve
Package Outline Dimensions
E
L2
b2
e
L1
c2
TO262
Dim Min Max Typ
D
A 4.06 4.83 4.57
A2 2.03 2.79 2.67
b 0.64 0.99 -
A2
L
b2 1.14 1.40 1.24
c 0.35 0.74 -
c2 1.14 1.40 1.27
D 8.64 9.65 8.70 E 9.65 10.29 10.11 e 2.54 Typ
b
c
L 12.70 14.73 13.60
L1 - 1.67 - L2
4.00 -
All Dimensions in mm
SBR40U100CTE
Document number: DS31459 Rev. 4 - 2
3 of 4
www.diodes.com
November 2011
© Diodes Incorporated
Page 4
IMPORTANT NOTICE
DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION).
Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document o r products described herein in such applica tions shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages.
Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorize d application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application.
Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks.
LIFE SUPPORT
Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein:
A. Life support devices or systems are devices or systems which:
1. are intended to implant into the body, or
2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the
labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems.
Copyright © 2011, Diodes Incorporated
www.diodes.com
SBR40U100CTE
SBR40U100CTE
Document number: DS31459 Rev. 4 - 2
www.diodes.com
4 of 4
November 2011
© Diodes Incorporated
Loading...