HIGH SENSIVITY MICROPOWER OMNIPOLAR HALL-EFFECT SWITCH
Description
The AH1810 is a high sensitivity micropower Omnipolar Hall effect
switch IC with internal pull up and pull down capability. Designed for
portable and battery powered equipment such as cellular phones and
portable PCs, the average supply current is only 6µA at 3V. To
support potable equipment the AH1810 can operate over the supply
range of 2.3V to 3.6V and uses a hibernating clocking system to
minimize the power consumption.
The output is activated with either a North or South pole of sufficient
magnetic field strength. When the magnetic flux density (B)
perpendicular to the package is larger than operate point (Bop), the
output will be turned on (pulled low). The output is turned off when
B becomes lower than the release point (Brp). The output will remain
off when there is no magnetic field.
H1810
Pin Assignments
Features
NEW PRODUCT
Omnipolar Operation (North or South Pole)
Supply Voltage of 2.3V to 3.6V
High Sensitivity
Micropower Operation
Chopper Stabilized Design Provides:
Superior Temperature Stability
Extremely Low Switch-Point Drift
Enhanced Immunity to Stress
No External Pull up Resistor Required
Good RF Noise Immunity
-40°C to +85°C Operating Temperature
Industry Standard SC59 Package
Totally Lead-Free & Fully RoHS Compliant (Notes 1 & 2)
Halogen and Antimony Free. “Green” Device (Note 3)
Notes: 1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant.
2. See http://www.diodes.com/quality/lead_free.html for more information about Diodes Incorporated’s definitions of Halogen- and Antimony-free, "Green"
and Lead-free.
3. Halogen- and Antimony-free "Green” products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and
<1000ppm antimony compounds.
Applications
Cover or Display Switch in Portable PCs
Open and Close Detect for Cellular Phones
Holster Detect for Cellular Phones and Tablet PCs
Digital Still and Video Cameras
Contact-Less Switches
Typical Applications Circuit (Note 4)
Note: 4. C
is for power stabilization and to strengthen the noise immunity, the recommended capacitance is 10nF to 100nF.
IN
AH1810
Document number: DS35743 Rev. 2 - 2
1 of 7
www.diodes.com
August 2013
© Diodes Incorporated
Pin Descriptions
Package: SC59
Pin
Number
1 VDD Power Supply Input
2 GND Ground Pin
3 OUTPUT Output Pin
Pin
Name
Functional Block Diagram
H1810
Function
NEW PRODUCT
AH1810
Document number: DS35743 Rev. 2 - 2
2 of 7
www.diodes.com
August 2013
© Diodes Incorporated
H1810
Absolute Maximum Ratings (Note 5) @T
Symbol Characteristics Values Unit
VDD Supply Voltage (Note 6) 6 V
V
DD_REV
I
OUTPUT
B Magnetic Flux Density Unlimited
PD Package Power Dissipation SC59 270 mW
Ts Storage Temperature Range +150 °C
TJ Maximum Junction Temperature 150 °C
ESD HBM Human Body Model ESD capability 8 kV
Notes: 5. Stresses greater than the 'Absolute Maximum Ratings' specified above may cause permanent damage to the device. These are stress ratings only;
functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be
affected by exposure to absolute maximum rating conditions for extended periods of time.
6. The absolute maximum V
device at the absolute maximum rated conditions for any period of time.
NEW PRODUCT
Recommended Operating Conditions (@T
Symbol Characteristic Conditions Rating Unit
VDD Supply Voltage Operating 2.3 to 3.6 V
TA Operating Temperature Range Operating -40 to +85 °C
Electrical Characteristics (@T
Symbol Characteristic Conditions Min Typ Max Unit
VOL Output Low Voltage (on) I
VOH Output High Voltage (off) I
Ioff Output Leakage Current Vout=3.6V, B < Brps
IDD(awake)
I
(sleep) During ‘sleep’ period — 2.5 — µA
DD
IDD(avg)
IDD(avg) VDD = 3.6V
Tawake Awake Active Pulse Width (Note 7)
Tperiod Awake Period (Note 7)
D.C. Duty Cycle
Note: 7. When power is initially turned on, the operating VDD (1.6V to 3.6V) must be applied to guaranteed the output sampling.
The output state is valid after the second operating cycle (typical 100ms).
Reverse Supply Voltage -0.3 V
Output current (source and sink) 2 mA
of 6V is a transient stress rating and is not meant as a functional operating condition. It is not recommended to operate the
DD
= +25°C, VDD = 2.3V to 3.6V, unless otherwise specified.)
A
Supply Current
Average Supply Current
= +25°C, unless otherwise specified.)
A
= +25°C, unless otherwise specified.)
A
= 1mA — 0.1 0.2 V
OUT
= -1mA V
OUT
During ‘awake’ period
V
= 3.0V — 6 10 µA
DD
-0.2 V
DD
—
—
—
—
—
—
-0.1 — V
DD
<0.1 1 µA
2.1
7.3 13 µA
50 100 µs
50 100 ms
0.1 — %
—
mA
AH1810
Document number: DS35743 Rev. 2 - 2
3 of 7
www.diodes.com
August 2013
© Diodes Incorporated