• Halogen and Antimony Free. “Green” Device (Note 3)
Notes: 1. No purposely added lead. Fully EU Directive 2002/95/EC (RoHS) & 2011/65/EU (RoHS 2) compliant.
2. See http://www.diodes.com/quality/lead_free.html for more information about Diodes Incorporated’s definitions of Halogen- and Antimony-free, "Green"
and Lead-free.
3. Halogen- and Antimony-free "Green” products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and
<1000ppm antimony compounds.
AH1807
Document number: DS35524 Rev. 3 - 2
www.diodes.com
Applications
• Smart E-Meters
• Tamper Protection Switch
• Door, Lids and Tray Position Switch
• Proximity and Position Switches
• Level Detects
• On/Off Switch Digital Contact-Less Switch in Industrial and
Notes: 6. Stresses greater than the 'Absolute Maximum Ratings' specified above may cause permanent damage to the device. These are stress ratings only;
functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be
affected by exposure to absolute maximum rating conditions for extended periods of time.
7. The absolute maximum V
operate the device at the absolute maximum rated conditions for any period of time.
Supply Voltage (Note 7) 7 V
Output Pin Voltage (Note 7) 7 V
Reverse Supply Voltage -0.3 V
Reverse Output Pin Voltage -0.3 V
Output Current (source and sink) 2.5 mA
Package Power Dissipation
Maximum Junction Temperature 150
of 7V is a transient stress rating and is not meant as a functional operating condition. It is not recommended to
DD
Recommended Operating Conditions(@T
Symbol Characteristic Conditions Rating Unit
VDD
V
OUT_MAX
TA
Electrical Characteristics (@T
Symbol Characteristic Conditions Min Typ Max Unit
V
OUT_ON
I
OFF
IDD(awake)
IDD(sleep)
IDD(sleep)
IDD(avg)
Tawake Awake Time (Note 8) — 75 125 µs
Tperiod Period (Note 8) — 75 125 ms
D.C. Duty Cycle — 0.1 — %
Note: 8. When power is initially turned on, the operating VDD must be within its correct operating range (2.5V to 5.5V) to guaranteed the output sampling.
The output state is valid after the second operating cycle (typical 150ms).
Symbol Characteristics Test Condition Min Typ Max Unit
Bops (south pole to part marking side)
Operation Point
Bopn (north pole to part marking side)
Brps (south pole to part marking side)
Release Point
Brpn (north pole to part marking side)
Bhy (|Bopx|-|Brpx|) Hysteresis (Note 11)
Notes: 9. Typical data is at TA = +25°C, VDD = 3V.
10. Parameters values over operating temperature range are not tested in production, they are guaranteed by design, process control and characterization.
The magnetic characteristics may vary with supply voltage, operating temperature and after soldering.
11. Maximum and minimum hysteresis is guaranteed by design and characterization.
= +25°C, VDD = 2.5V to 5.5V, unless otherwise specified.)