Dinuy IT KNT 004, IT KNT 008, IT KNT 016 User Manual

IT KNT 004 / IT KNT 008 / IT KNT 016 4-/8-/16-channel KNX Multifunctional Actuators with 12 / 23 Binary/Analog Inputs
For more information: www.dinuy.com
Description
KNX Multifunction Actuators that can work as:
• IT KNT 004: 4-channel Switching Actuator or 2-channel
Blinds/Shutters Actuators.
• IT KNT 008: 8-channel Switching Actuator or 4-channel Blinds/Shutters Actuators.
High load capacity, with 16A built-in relays, as well as a zero-crossing­point control, which allows switching very high loads, even capacitive type.
Incorporate 12 / 12 / 23 Inputs:
IT KNT 004: 8-Binary Inputs + 4-Binary/Analog Inputs
IT KNT 008: 8-Binary Inputs + 4-Binary/Analog Inputs
IT KNT 016: 16-Binary Inputs + 7-Binary/Analog Inputs
These inputs can be independently parameterized through the ETS
Software:
Binary Input: allows the connection of a conventional voltage-free binary sensor or switch.
Analog Input: allows the connection of a DINUY temperature probe (ST KNT 001 or ST KNT 002).
Incorporates a front keypad for independent manual control of each output, as well as status indicator LEDs.
Allows to enable and configure up to 4 / 4 / 7 independent Heating and or Cooling Thermostats.
It incorporates 8 / 8 / 16 Logic Functions, Centralized Control, Scenes, Time Function, etc.
Possibility of connecting different phases in each output channel.
Integrated Bus Coupling Unit (BCU).
DIN-rail mounting, 4 / 4 / 8 modules wide.
Programming and commissioning via ETS5 or later versions.
IT KNT 004 / IT KNT 008 / IT KNT 016 4-/8-/16-channel KNX Multifunctional Actuators with 12 / 23 Binary/Analog Inputs
For more information: www.dinuy.com
Technical Data
Nominal Voltage
230V~ 50Hz
KNX
Voltage range
21 ~ 32VDC
Consumption
IT KNT 004: < 7mA IT KNT 008: < 7mA IT KNT 016: <9mA
Connection type
KNX Bus connector
Commissioning
ETS5 or later
KNX Media
TP1
Configuration Mode
System Mode
Inputs
Number of Inputs
IT KNT 004: 4 Binaries + 8 Binaries/Analogs IT KNT 008: 4 Binaries + 8 Binaries/Analogs IT KNT 016: 7 Binaries + 16 Binaries/Analogs
Type
Binaries or Analogs
Cable maximum length
Binary Inputs: <200m Binary/Analog Inputs: <10m
Scanning voltage
20VDC
Input current
0,5mA
Outputs
Channels
IT KNT 004: 4 Switching or 2 Blinds IT KNT 008: 8 Switching or 4 Blinds IT KNT 016: 16 Switching or 8 Blinds
Load LED Lamps Incandescence Motors
16A / 250V~ per channel 400W 3000W 700VA
Isolating Voltage
4KVAC (supply/bus voltage)
Cable section
2,5mm2
Dimensions
IT KNT 004: 4 DIN units (70mm) IT KNT 008: 4 DIN units (70mm) IT KNT 016: 8 DIN units (140mm)
Working temperature
-5ºC ~ +45ºC
Storage temperature
-30ºC ~ +70ºC
Protection degree
IP20 (EN60529)
Directives
Low-voltage 73/23/EEC EMC 204/108/EC
According to the Standards
KNX Standard 2.0 EN60669-1, 2-1 y 2-3
Marking
EIB/KNX