7
CAUTION: Ensure installation
does not allow replace to be in
direct contact with building vapor
barrier or insulation and meets all
local building code.
!
NOTE: A dedicated, properly
fused 15 Amp circuit is required, rated for the appropriate voltage (120V, 240V).
WARNING: Construction and
wiring must comply with local
building codes and other applicable regulations to reduce
the risk of re, electric shock
and injury to persons.
WARNING: To reduce the risk
of re, electric shock or injury to
persons, always use a licensed
electrician.
WARNING: To reduce the risk
of re, do not store or use gasoline or other ammable vapors or
liquids in the vicinity of the heater.
1. Select a location that is not
susceptible to moisture and
is away from drapes, furniture
and high trafc.
2. Unpack the replace and hard-
ware from the box.
!
NOTE: Leave the front glass
and partially reective glass,
safely, in the box until the time
Fireplace Installation
you are ready to install it.
3. Store the replace in a safe,
dry and dust free location until
you are ready to install the
replace.
Installation
CAUTION: Two people will be
required for various steps of
this procedure.
This design of this unit allows
three options for installation:
partial recess, ush mounted or
sub-surface mounted.
CAUTION: Sub-surface
mounting should be limited
to ½ in. (10 mm) to ensure
adequate air ow of heated air
out of the rebox area.
1. Prepare a wall with a framed
opening of 16 in. (40.6 cm)
high,
• XLF50 - 50 ⅝ in. (128.7 cm)
• XLF74 - 74 ⅝ in. (189.7 cm)
• XLF100 - 100 ⅝ in. (255.7 cm)
wide, with a bottom sill that is
a minimum of 4 in. (10.2 cm)
deep. The sill can be constructed to support the front
of the unit to allow the power
supply wires to easily be run
behind or ush with the back
of the unit and a pass thru