Dimplex VR15, VR20, VR30, VR40, VR45 Installation And Operating Instructions Manual

...
Installation and Operating Instructions
8/18149/0
Quartzray Vector Range
Models Covered: Model Heating Elements Voltage Weight
Vector I VR15 1 x 1.5kW 230-240V 2.2kg
VR20 1 x 2.0kW 230-240V 2.2kg
Vector II VR30 2 x 1.5kW 230-240V 4.0kg
VR40 2 x 2.0kW 230-240V 4.0kg
Vector III VR45 3 x 1.5kW 230-240V/400-415V 5.8kg
VR60 3 x 2.0kW 230-240V/400-415V 5.8kg
Vector IRP VR15RP 1 x 1.5kW 230-240V 2.2kg
VR20RP 1 x 2.0kW 230-240V 2.2kg
IMPORTANT These instructions should be read and carefully retained by the user.
The installation of these appliances must always be carried out by a competent electrician and be in accordance with the current IEE wiring regulations and relevant Building Regulations.
The radiated heat from the heater is considerable and must be taken into account when siting the heater. Ensure that the heater is not used in close proximity to the skin or eyes.
Always isolate the heater from the supply before undertaking any maintenance work of the appliance.
The Vector range of heaters are designed for internal use only. They are not rated as flame -proof and must not be used when flammable dusts, gases, or vapours, etc., are likely to be present in the atmosphere. If in doubt, advice should be sought from the Health and Safety Executive inspectors or local fire officers.
Quartz lamps are extremely fragile and must be handled with extreme care at all times. Avoid touching the surface of the quartz sleeve with bare fingers. If the sleeve is accidentally touched remove the finger print with a soft cloth moistened with methylated spirits.
As with any fragile fitting mounted above head height, care must be taken when siting the heater to avoid locations where it may be subjected to knocks. In high risk areas such as sports halls etc. extra guarding may be required to protect the heater from flying objects.. If in doubt consult the heater manufacturer.
WARNING THIS APPLIANCE MUST BE EARTHED. HEATERS MUST BE
MOUNTED OUT OF REACH FROM OVERHEAD WALKWAYS AND OPENING WINDOWS. THE HEATER MUST BE SECURELY FIXED AS IT WILL BE DANGEROUS IN THE EVENT OF ANY INSECURITY IN ITS FIXINGS.
SPECIFICATIONS The Quartzray Vector range is available in 1,2 and 3 lamp models with
outputs of 1.5kW, 2kW, 3.0kW, 4kW, 4.5kW, and 6kW respectively. The Vector III lamp model is supplied as a dual voltage unit and is suitable for use on 230­240V 1pH and 400-415V 3N supplies.
ASSEMBLY
VECTOR 1
Remove the front assembly (see fig.1) and disconnect the lamp leads from the terminal block. Remove knockout(s) as shown in fig.2. DO NOT attempt to remove knockouts on assembled heater as this will cause damage to the fragile lamps.
If a guard is to be fitted it is necessary to remove one end cap from the heater front (see fig.3).
VECTOR RP Similar to Vector 1 but rain cover must be removed
before front assembly can be removed (see fig 4).
IMPORTANT The supply cable MUST enter the back box from below on this rain-proof model to prevent water entering the heater. If the heater is to be wall mounted the two
screws/nuts retaining the cover support bracket will need to be removed.
VECTOR II Remove two front assemblies (see fig.1) and centre cover (3 screws). Remove knockout for cable entry as shown in (fig.2). DO NOT attempt to remove knockout on assembled heater as this will cause
damage to the fragile lamps. The incoming supply cable must enter by one of the three knockout positions inside the centre cover. DO NOT use the two chain hook holes at each end of the back box.
If guards are to be fitted remove one end cap from each front assembly (see fig.3).
VECTOR III
Remove three front assemblies (see fig.1) and two centre covers (3 screws each). Remove knockout for cable entry as shown in (fig.2). DO NOT attempt to remove knockout on assembled heater as this will cause damage to the fragile lamps.
The incoming supply cable must enter by one of the three knockout positions behind the right hand centre cover. DO NOT use the two chain hook holes at each end of the back box.
INSTALLATION
FLOOR WALLS & CEILINGS
The minimum mounting heights are: -
1. Vector I and Vector RP 1.8M
2. Vector II 2.5M
3. Vector III 3.0M (Also applies to apposite wall when wall mounted) The above dimensions also apply to the distance
required to a side wall when suspended and a distance of 1.0M is required to any end wall for all heaters regardless of type of mounting.
Allow a minimum space above heaters of 150mm to any overhang or ceiling. Do not locate heater immediately below any socket outlet.
VECTOR 1
a. Wall mounting – screw back box to wall using
2 holes (see fig.2).
b. Bracket mounting – fit bracket to wall and back
Box to bracket (see fig.5).
c. Suspended mounting – remove 2 knockouts
(see fig.2) and suspend back box using conduit or chain hooks.
VECTOR RP
a. Bracket mounting only – fit bracket to wall and
back box (cover support fitted) to wall bracket (see fig.5).
VECTOR II & III
a. Wall mounting – screw back box to wall using the 2
or 3 holes provided.
b. Suspended mounting – suspend back box using
conduit or chain hooks.
Fit front assemblies to heater (see fig.7) and adjust reflector angle to suit and on Vector RP, re-fit rainproof heater.