Line Voltage Electric Heater
Thermostat
TS521W/TD522W Series
FEATURES
Clean, attractive style suits any decore wall-mount design sits ush
against wall. Includes both oC and oF control dials
SPECIFICATIONS
Electrical Ratings:
0 - 2640 watts max. at 120 volts (22 amps)
0 - 4576/5280 watts at 208/240 volts (22 amps)
0 - 4986 watts at 277 volts (18 amps)
Sensing Element: Bimetal
Temperature Operating Range: 5
Approvals:
Underwriters Laboratories Inc No.: E105830
Canadian Standards Association No.: LR30410
o
- 35oC and 41o - 95oF
Figure 1
Cover
Recycling Notice
At the end of the electrical products useful life it should
not be disposed of with household waste. Please recycle
where facilities exist. Check with your Local Authority or
retailer for recycling advice in your country.
Screw
Index Plate
Base
Outlet Box
Installation Instructions
Mounting: Mounts directly into a standard 2 x 4 inch vertical electri-
cal outlet box
SINGLE POLE THERMOSTAT INSTALLATION
WARNING: The installation of the thermostat must comply with
the applicable Local and/or National Electrical Codes and utility
requirements. This installation should be entrusted to duly qualied
personnel where required by law.
WARNING: Ensure that all wiring connections to the thermostat
are correct and tight to prevent electrical shorts. Use the appropriate
wire to meet local and national electrical codes for rated power
consumption.
Disconnect power supply to prevent electrical shock or product 1.
damage.
Run line voltage wiring to the thermostat location.2.
Do not remove the thermostat cover.3.
7207610100R01
Figure 2 - Single Pole Thermostat
Power Supply
Load Black
Wire
Connector
L1 from
Line Red
Thermostat
Neutral from
Power Supply
Heater
Figure 3 - Double Pole Thermostat
L1 from
Power Supply
Line Red
Load Black
Connect the red LINE lead on the thermostat to the L1 line 4.
from the power supply panel.
Connect the black LOAD lead from the thermostat to the line 5.
lead on the heater.
Connect the N Neutral (or L2) line to the remaining line of the 6.
heater.
Secure the ground wire to the ground screw provided in the 7.
outlet box.
Ensure that all connections are tight.8.
Insert wires into the outlet box taking care not to damage the 9.
sensing device or wiring.
Remove the thermostat cover by grasping the cover by the 10.
sides and pulling it away from the thermostat base.
Mount the thermostat base into the wall box and secure using 11.
the two supplied screws.
!
NOTE: Do not over tighten mounting screws
Replace thermostat cover.12.
DOUBLE POLE THERMOSTAT INSTALLATION
WARNING: The installation of the thermostat must comply with
the applicable Local and/or National Electrical Codes and utility
requirements. This installation should be entrusted to duly qualied
personnel where required by law.
WARNING: Ensure that all wiring connections to the thermostat
are correct and tight to prevent electrical shorts. Use the appropriate
wire to meet local and national electrical codes for rated power
consumption.
Disconnect power supply to prevent electrical shock or product 1.
damage.
Run line voltage wiring to the thermostat location.2.
Do not remove the thermostat cover.3.
Thermostat
Neutral from
Power Supply
Wire
Connector
Heater
Connect the black LOAD leads on the thermostat to the leads 4.
on the heater.
Connect the red LINE leads on the thermostat to the line leads 5.
from the power supply panel.
Ensure that all connections are tight.6.
Insert wires into the outlet box taking care not to damage the 7.
sensing device or wiring.
Secure the ground wire to the ground screw provided in the 8.
outlet box.
Remove the thermostat cover by grasping the cover by the 9.
sides and pulling it away from the thermostat base.
Mount the thermostat into the wall box and secure using the 10.
two supplied screws.
!
NOTE: Do not over tighten mounting screws
Replace thermostat cover.11.
Operation
To adjust the temperature to your individual requirements, turn
the thermostat control clockwise all the way to turn on the heater
(Figure 4). When the room reaches the desired temperature, turn
the thermostat knob counter clockwise until you hear a click. Leave
in this position to maintain the room temperature at this setting. For
additional heat, turn clockwise until you hear the click again and the
heater will turn on.
For single pole models:- Turning the knob fully counter clockwise
will set the temperature rating to 5
For double pole models:-Turning the knob fully counter clockwise
will disconnect the power to the heater.
INDEX PLATE REMOVAL (Figure 5)
Using a small at screwdriver or other suitable tool gently pry up on
one of the slots located on the index plate. To install line up the index
plate pins with the holes in the thermostat knob and push until the
index plate is ush with the thermostat knob.
Figure 4
o
C (41oF).
Figure 5
Warranty
LIMITED WARRANTY:
against defects in workmanship and materials for one year from
date of sale. This warranty does not apply to damage from accident,
misuse, or alteration, nor where the connected voltage is more that 5
% above the nameplate voltage, nor to equipment improperly installed
or wired or maintained in violation of the instruction sheet. This
limited warranty applies only to purchases made in any province of
Canada except for Yukon Territory, Nunavut, or Northwest Territories
or in any of the 50 States of the USA (and the District of Columbia)
except for Hawaii and Alaska. This limited warranty applies to the
original purchaser of the product only and is not transferable. No
other written or oral warranty applies. No employee, agent, dealer
or other person is authorized to give any warranties on behalf of
Dimplex. The customer shall be responsible for all costs incurred in
the removal or reinstallation and shipping of the product for repairs.
Within the limitations of this warranty, inoperative units shall be
returned to the nearest Dimplex authorized service center, and we
shall repair or replace, at our option, at no charge to you with return
freight paid be Dimplex. It is agreed that such repair or replacement
is the exclusive remedy available from Dimplex and that DIMPLEX IS
NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING
INCIDENTAL AND CONSEQUENTIAL DAMAGE. Some States do
not allow the exclusion or limitation of consequential damages, so
the above exclusion or limitation may not apply to you. This warranty
gives you specic legal rights and you may also have other rights
which vary from state to state.
1367 Industrial Road
1-888-346-7539
In keeping with our policy of continuous product improvement,
we reserve the right to make changes without notice.
All Dimplex Thermostats are warranted
Cambridge ON Canada N1R 7G8
www.dimplex.com
© 2011 Dimplex North America Limited