SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 2 of 52
R02893-1 10/13
0 Contents
0 CONTENTS 2
1 BEFORE YOU START 3
1.1 GENERAL 3
1.2 COMPETENCE 3
1.3 HEALTH AND SAFETY 3
1.4 RISK ASSESSMENT 5
1.5 TOOLS REQUIRED 5
1.6 EARTHING AND LIGHTNING PROTECTION 5
1.7 PIPE WORK 5
2 SCOPE OF DELIVERY 6
3 PRODUCT FEATURES AND DESCRIPTIONS 11
4 COLLECTOR CONNECTIONS 11
4.1 SINGLE COLLECTOR PORTRAIT CONNECTION 11
4.2 MULTIPLE COLLECTOR PORTRAIT CONNECTION 12
5 INSTALLATION 13
6 OPERATION & MAINTENANCE 49
7 SPARE PARTS 50
8 DECOMMISSIONING 51
9 TECHNICAL DATA 51

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 3 of 52
R02893-1 10/13
1 Before you start
1.1 General
Thank you for choosing a Dimplex product. We ensure you that every effort has been
made at the design, manufacture and delivery stages to produce a product with superi-
or quality. We will provide you with the best possible support throughout the product’s
lifespan.
As part of on-going product development and improvement Dimplex reserves the right
to undertake changes to the product without prior notice. Great care has been taken to
ensure this manual was correct at the time of print. Should you however discover any
issues with the information contained therein please do not hesitate to contact your
vendor.
We strongly recommend reading the whole contents of this manual before commencing
the work.
1.2 Competence
Dimplex products have been designed and manufactured to the current relevant standards and under stringent quality control procedures. It is therefore imperative that the
product is only installed by a:
- trained and
- competent
person as defined in the relevant regulations. Dimplex does not accept any liability for
damage done to persons or property resulting from undue handling and usage of this
product.
All regulations current at the time of installation are to be considered alongside the content of this manual as they form the code of best practice.
The warranty of this product is linked to the ability to prove that the product was installed, commissioned and maintained:
- by a competent person
- in accordance with Dimplex instructions and the current relevant regulations and legislation
- the product being registered with Dimplex at the time of installation using the form in
the Dimplex On Site Guide
- records showing the date of maintenance in accordance with the maintenance schedule as detailed in the On Site Guide
1.3 Health and Safety
The installation of this product is subject to the Health and Safety at Work Act. It is
your responsibility to ensure that the transport, storage, installation and operation of
the product is carried out in a safe manner.
Dimplex will not accept any liability due to damage caused to people or property resulting from negligence or not adhering to the relevant Health and Safety practices.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 4 of 52
R02893-1 10/13
Figure 1: Safety information
The manufacturer hereby guarantees to take back
products identif ied with an eco-label and to recycle
the materials used. Only the heat transfer medi um
specifi ed may be used!
Wear a helmet when carrying out installation
work!
Wear protective goggles whe n drilli ng and
handling coll ectors!
Wear cut-proof safety gloves when mounting
collectors!
Wear safety shoes when carrying out install ation
work!
1 m ................voltages up to 1000V
2 m ................voltages from 1000V to 11000V
3 m ................voltages from 11000V to 22000V
4 m ................voltages from 22000V to 38000V
> 5 m in case of unknown voltages
Whenever you are near live overhead el ectric cables
where contact is possible, only work if:
- it is ensured that they are voltage-free and this
is secured for the duration of work.
- the live parts are secured by covering them or
- the prescribed safe ty distances are maintained.
If non-personal fall protection or fall-arrest systems
are not provided, working without the use of
suitable safety harnesses may lead to falls from
heights and therefore cause serious or lethal
injuries!
Only lean ladders against secure points. Secure
ladders in traffi c areas by suitable cordoning.
Ladders not properly secured against sinki ng in,
slidi ng or falling over may lead to dangerous falls!
Contact with live electric overhead cables can be
lethal.
If non-personal fall protection or fall-arrest systems
cannot be installe d for technical reasons, all
personnel must be secured by means of suitable
safety harnesse s!
Never use damaged ladders (e.g., wooden ladders
with spli t runners or rungs, or bent or buckled
metal ladders). Never try to repair broken runners,
rungs or steps on wooden ladders!
Only use safe ty harnesses (safe ty belts, lanyards and
straps, shock absorbers, fall arresters) that were
tested and certifi ed by authorized testing bodies.
Ensure that ladders are put up safely. Observe the
correct leaning angle (68° - 75°). Prevent ladders
from slidi ng, falli ng over or sinking into the ground
(e.g. usi ng wider fee t, feet suited to the ground or
hooking devices).
Safety precautions: Bef ore commencing mounting
work on roofs, it must be ensured in all cases that the
non- personal fal l protection and fall-arrest systems
required by DIN 18338 (Roof Covering and Roof
Sealing Works) and DIN 18451 (Scaffolding Works) are
in place. See also Builders‘ Protection Ordinance
[Bauarbeiterschutzve rordnung], Federal Law Gazette
340/ 1994, paragraphs 7-10! Other country-specific
regulations must be observed!
Safety harnesses should be fixed above the use rs
whenever possible. Safety harnesses should only
be fastene d to sufficiently load-be aring structures
or fixing points!

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 5 of 52
R02893-1 10/13
1.4 Risk assessment
The compilation of a risk assessment is strongly recommended before installing the
product. The following areas require particular consideration in addition to the information required by the Health and Safety at Work Act.
- scalding: where appropriate or required by law a thermostatic mixing valve is to be
fitted to the hot water outlet of the cylinder
- explosion: the unit is fully equipped with all relevant safety equipment to comply with
current regulations. The correct design and function has been verified by independent
third party testing. The correct application thereof is the responsibility of the competent installer.
- water borne organisms (i.e. Legionella): if applicable a risk assessment should be
carried out following the recommendations outlined in the Approved Code of Practice
L8.
- the user preference must be considered when commissioning the system, in particular
when adjusting the solar and auxiliary system temperature and timer settings.
1.5 Tools required
It is recommended that the below list of tools be used when installing the integrated
roof kit.
- 2 people required for installation
- Measuring tape
- Hammer
- Drill
- Adjustable pliers
- Angle grinder with stone disc
- TX 25 x 25mm torque bit
- Spirit level
- Plumb line
- Additional wood (as required)
- Pop-rivet gun
In addition to the above tools it may be required to wear suitable safety gloves upon
installation as the kit consists of sheet metal which may cause cuts if care is not taken
during handling of the product.
1.6 Earthing and Lightning Protection
If a lightning arrester is available, the collector frame should be connected to it. This
may be performed using the collector frame, because the slot for mounting on the reverse side of the collector is ideally suited for fixing a thick cable. If no arrester is available, the potential equalization is carried out using a connection of a cable at the
pipe(s) which are led into the building. Please consult local regulations to ensure adherence.
1.7 Pipe Work
The pipe work from the collector to the pump unit and from the pump unit to the cylinder is to be all metal. The joints have to be high temperature resistant (compression or
high temperature flat seal). For more information please see Technical Manual.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 6 of 52
R02893-1 10/13
The connections of a mounted solar collector/collector array may become excessively
hot so care must be taken to avoid burns when working around collectors that are exposed to the rays of the sun.
2 Scope of delivery
Please check the contents and the condition of your delivery before signing the delivery
documentation against the content shown in Table 1 and mark as appropriate. Contact
your supplier immediately for any missing or damaged parts. Claims for missing or
damaged parts after signing for the delivery documentation will not be accepted.
Table 1: Overview of flashing components part 1
These mounting instructions
only apply to the installation of
the in roof flashing and the
fixation of the collectors!
Useable from 20° roof pitch!
Part No. Spare No. Description
P31 74011 left front part
P32 74012 centre front part
P33 74013 right front part
P34 74220 lateral fixation bracket
P35 74222 centre fixation bracket
P36 74111 left lateral part
P37 74113 right lateral part
P38 74001 left collector cover
P39 74002 centre collector cover
P40 74003 right collector cover
P41 74230 connection strip
P42 74090 wooden wedge 600 mm
P43 74091 wooden wedge 1200 mm
P44 74061 left back part
P45 74062 centre back part
P46 74063 right back part
P47 74070 back part connection

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 7 of 52
R02893-1 10/13
Table 2: Overview of flashing components part 2
Useable from 20° roof pitch!
Part No. Spare No. Description
P48 74014 front part single collector
P34 74220 lateral fixation bracket
P36 74111 left lateral part
P37 74113 right lateral part
P49 74004 single collector cover
P43 74091 wooden wedge 1200 mm
P50 74064 back part single collector

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 8 of 52
R02893-1 10/13
Table 3: Scope of components
# Letters D to K are for the On-Roof Installation
SOL202TIP
A 1 2 3 4
B 1 1 1 1
P01
P02 22mm stop end x2
C 0 1 2 3
P03 22mm x 22mm straight compression x2
#L 1 0 0 0
P48 front par t single colle ctor
P34 lateral fixation bracket
P49 single collector cover
P36 left latera l part
P37 right latera l part
P43 wooden wedge 1200m m
P50 back part single collector
M 0 1 1 1
P31 left front pa rt
P33 right front part
P34 lateral fixation bracket
P35 centre fixation bracket
P38 left collector cov er
P40 right collector cov er
P36 left latera l part
P37 right latera l part
P41 connection strip
P42 wooden wedge 600m m
P43 wooden wedge 1200m m
P44 left back part
P46 right back part
P47 back part conne ction
N 0 0 1 2
P32 centre front part
P35 centre fixation bracket
P39 centre collector cover
P41 connection strip
P43 wooden wedge 1200m m
P45 centre back part
P47 back part conne ction
Hydr aulic inte rco nnec tion s et
Tile inte gra ted s et 2.02m²
Tile inte gra ted s et 4.02m²
Tile inte gra ted s et e xte nsion
Sola r flat plate colle ctor 2.02m ²
Hydr aulic co nnec tion s et

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 9 of 52
R02893-1 10/13
Table 4: Images of components part 1

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 10 of 52
R02893-1 10/13
Table 5: Images of components part 2

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 11 of 52
R02893-1 10/13
3 Product features and descriptions
The Dimplex Tile Integrated Roof kit offers a unique solution for mounting solar thermal
collectors to the roof of a building. The concept of the product is to make the installation of the collectors a quick and simple process.
The Tile Integrated Roof Kit can cater for 2m² up to 8m² of collector area and comes in
four variations, 2m² kit, 4m² kit, 6m² kit and 8m² kit.
The product consists of various aluminium flashings and fixings that seal the collector
against the roof covering in an aesthetically pleasing way. The collector is an integral
part of the assembly and forms part of the weather tightness of the roof.
4 Collector connections
Due to its four connections, the collector offers a wide choice of connection options.
Ensure that no part of the collector array or collector in the array is short circuited by
following these instructions.
When planning the collector array, the position of the various connection parts must be
in accordance with the diagrams, also pay attention to the position of the highlighted
sensor pocket.
Table 6 illustrates the components required to make all the collector connections.
Table 6: Collector connection components
4.1 Single collector portrait connection
When installing a single collector installation, there is one connection option available.
The sensor must always be installed at the top of the collector and on the connection
where the heat transfer fluid leaves the collector.
Figure 2 illustrates the left hand side connection option that is applicable only to a single portrait collector connection.
Part No Image Description
P01 22mm x 90° elbow
P02 22mm stop end
P03 22mm x 22mm straight compression

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 12 of 52
R02893-1 10/13
Figure 2: Left hand side connection option for single collector only
4.2 Multiple collector portrait connection
When installing multiple collectors, (2 up to 4), component P03 is used to connect one
collector to the next.
Figure 3: Multiple collector portrait connection
The sensor must always be installed at the top of the collector on the connection flow of
the system.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 13 of 52
R02893-1 10/13
5 Installation
NB: Ensure all the laths / roof battens under the area of the installation are in good
condition. Replace any damaged, week or broken laths and double nail or screw to the
rafters.
Figure 4: Mounted dimensions

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 14 of 52
R02893-1 10/13
For the stabilisation of the front
parts mount an additional roof batten as shown in Step 1 and 2.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 15 of 52
R02893-1 10/13
Place the left front part on
the roof batten and fix it
with 12 sealing screws
(Step 4 and 5).

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 16 of 52
R02893-1 10/13
Place the centre front part on the
roof batten and plug it together with
the left front part (Step 7).
In the case of a 2-collector installation please continue with Step 10.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 17 of 52
R02893-1 10/13
Fix the centre front part with 12
sealing screws Step 8 and 9.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 18 of 52
R02893-1 10/13
Place the right front part on the roof
batten and plug it together with the
centre (left) front part.
Then fix it with sealing screws.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 19 of 52
R02893-1 10/13
Place the first collector. Fit it into
the flaps on the front part as shown
in Step 13 and 14.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 20 of 52
R02893-1 10/13

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 21 of 52
R02893-1 10/13
Place the collector so that it
is aligned with the marking
on the left front part.
Fix the collector on the left
(outer) side with 4 lateral fixation
brackets.
Place the brackets to the collector
as shown in Step 17 and fix every
lateral fixation bracket with 2 No.
5x30mm wood screws.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 22 of 52
R02893-1 10/13
Place 4 centre fixation brackets
to the collector as shown in Step
19. Fix every bracket with 2 No.
5x30mm wood screws.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 23 of 52
R02893-1 10/13
Position 22 x 22mm straight
compression fittings on 1st collector
loosely before fitting 2nd collector.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 24 of 52
R02893-1 10/13
Allow the 2nd collector to rest into the
flaps offset slightly to the right. Gently
taking the weight off the collector, move
it to the left, ensuring the collector engages in the centre fixation brackets of
the 1st collector (Step 22) and into the
flaps of the centre front part (Step 13)
and the loosely fitted compression fittings (Step 20).
The distance between the collectors
should be about 55mm and this should
ensure a neat fit with the centre fixation brackets (Step 22).

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 25 of 52
R02893-1 10/13
Fix every centre fixation bracket
with 2 additional 5x30mm wood

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 26 of 52
R02893-1 10/13
Position 22 x 22mm straight compression fittings on 2nd collector
loosely before fitting 3rd collector.
Place 4 centre fixation brackets
on the right side of the 2nd
collector (Step 19) and fix every bracket with 2 No. 5x30mm

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 27 of 52
R02893-1 10/13

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 28 of 52
R02893-1 10/13
Fix the right (outer) side of the
collector with 4 lateral fixation
brackets.
Fit collector connections and sensor
and pressure test and insulate.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 29 of 52
R02893-1 10/13
Fit the left lateral part to the collectors profile as shown in Step 32.
On the lower side the upper perforation should be aligned with the collectors profile as shown in Step 34.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 30 of 52
R02893-1 10/13
Align the upper perforation
with the collector edge!
Bend the lateral part along
the perforation as shown
in Step 34 and 35.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 31 of 52
R02893-1 10/13
Bend the flap on the left
front part so that it fits on
the lateral part (Step 36
and 37).

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 32 of 52
R02893-1 10/13
Fix the left lateral part with
4 fixation brackets and a
nail and ensure the foam
gasket is fitted parallel to
the inner side of the fold.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 33 of 52
R02893-1 10/13
Fit collector connections and pressure test and insulate.
Mount the right lateral part
in the same way like the
left one.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 34 of 52
R02893-1 10/13
Collector ventilation
opening
Important!
Always check that the opening on the
cover fits the ventilation opening of the
collector. See Step 42a.
Mount the left collector cover
and fit into the collector profile
as shown in Step 42 and 43.
Important!
Check the engraved number on the cover.
Cover for left collector: 74001
Cover for centre collector: 74002
Cover for right collector: 74003

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 35 of 52
R02893-1 10/13
Important!
Check the engraved number on the cover.
Cover for left collector: 74001
Cover for centre collector: 74002
Cover for right collector: 74003
Mount the centre collector cover
and fit into the collector profile
as shown in Step 42 and 45.
Important!
Always check that the opening on the
cover fits the ventilation opening of the
collector. See Step 42a.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 36 of 52
R02893-1 10/13
Important!
Check the engraved number on the cover.
Cover for left collector: 74001
Cover for centre collector: 74002
Cover for right collector: 74003
Mount the right collector
cover following the same
procedure as for the left
and centre cover
Important!
Always check that the opening on the
cover fits the ventilation opening of the
collector. See Step 42a.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 37 of 52
R02893-1 10/13
Mount the collection strips
between the collectors.
Just plug them into the collector profiles as shown in Step
48.
You can use the connection
strips in both directions (there
is no upper or lower side).

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 38 of 52
R02893-1 10/13
Align upper
perforation
with collectors
edge!
Bend the connection strip
along the perforations on
the lower side.
Place the connection
strips so that the upper
perforation on the lower
side is aligned with the
collectors edge.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 39 of 52
R02893-1 10/13
Before the mounting of the
wooden wedges and the back
parts, mount additional roof
battens to stabilise the back
parts and the wooden wedges
as shown in Step 52.
Bend the connection strip
along the perforations on
the upper side.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 40 of 52
R02893-1 10/13
Place the wooden wedges
on the upper side of the
collectors as shown in
Steps 54 and 55.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 41 of 52
R02893-1 10/13
Fix every wooden wedge
with 2 No. 5x50mm and
5x70mm wood screws.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 42 of 52
R02893-1 10/13
Fit the left back part into
the left lateral part and to
the collectors profile as
shown in Steps 58 and 59.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 43 of 52
R02893-1 10/13
Fix the left back part with
3 No. sealing screws.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 44 of 52
R02893-1 10/13
Fix the centre back part
with 2 No. sealing screws.
Fit the centre back part to the
collectors profile as shown in
Step 58.
In the case of a 2 collector
installation please continue
with Step 63.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 45 of 52
R02893-1 10/13
Fix the right back part with
3 No. sealing screws.
Fit the right back part into
the right back lateral part
and to the collectors profile
as shown in Step 58 and 64.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 46 of 52
R02893-1 10/13
Fix the left and the right back part
with a rivet and a fixation bracket
with a nail (Step 65 and 66).

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 47 of 52
R02893-1 10/13
Place the back part connections
on the back part as shown in Step
68.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 48 of 52
R02893-1 10/13
Fix every back part connection
with 4 No. sealing screws.
Place foam gaskets along the
lateral and back parts.

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 49 of 52
R02893-1 10/13
6 Operation & Maintenance
Connections should be double checked prior to commissioning of the system. Please
refer to the On Site Guide for guidance on how to commission and operate the solar
system.
Risk of scalding! Before carrying out any maintenance work on the system ensure that
it is safe to do so. The solar system must be decommissioned before work can be carried out. Refer to the On Site Guide for a maintenance schedule of the complete system.
Check for leaks at the collector connections and other connections in the system. Also
ensure pipe insulation is intact and in good condition.
Finally form the
aluminium apron to
the contours of the
roof tiles as shown in
Step 71 and fix it
with the adhesive
strip.
Take care that the
roof tiles are clean!

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 50 of 52
R02893-1 10/13
7 Spare Parts
Table 7: Spare parts
Part No. Spare No. Description
P31 74011 left front part
P32 74012 centre front part
P33 74013 right frontpart
P34 74220 lateral fixation bracket
P35 74222 centre fixation bracket
P36 74111 left lateral part
P37 74113 right lateral part
P38 74001 left collector cover
P39 74002 centre collector cover
P40 74003 right collector cover
P41 74230 connection strip
P42 74090 wooden wedge 600 mm
P43 74091 wooden wedge 1200 mm
P44 74061 left back part
P45 74062 centre back part
P46 74063 right back part
P47 74070 back part connection
P48 74014 front part single collector
P49 74004 single collector cover
P50 74064 back part single collector
R02893-1 R02893-1 manual
74357 bag of fittings

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 51 of 52
R02893-1 10/13
8 Decommissioning
Risk of scalding! Before carrying out any decommissioning work on the integrated roof
kit, please ensure the solar system has been decommissioned.
If the product is being recycled, local waste disposal laws must be adhered to.
9 Technical Data
Table 8: Collector technical data
Figure 5: Pressure loss collector for anti-freeze / water mixture (40% / 60%) at a thermal conduct-
ing temperature of 50° C.
Weight e mpty
33 kg
Dimensions
- length
1730mm
- width 1170mm
- height
83mm
Heat transfe r medium
SOLHT20
Max o p. pr es. [bar ] 10
Tilt angle
- min 20°
- max 75°
Collector array [m²] 2 4 6 8
Cu pipe [mm] 15 15 22 22
Wind / snow load [kN/m²] 1.9 1.9 1.9 1.9

SOL202TIP – SOL808TIP - Tile integrated roof kit manual
Page 52 of 52
R02893-1 10/13