Dimplex RFI815D31W, RFI820D41, RFI820D31, RFI820D31W, RFI820D41W Installation, Operation & Maintenance Instructions Manual

...
Forced Air Heater
1-888-346-7539
Installation, Operation & Maintenance Instructions
Remove heater from carton. The front grille and trim can be lifted off assembly, and placed in carton to prevent damage. Remove screws securing heater assembly to the recess box and separate. (Fig. 1).
Note - Mount the heater a minimum of 12” (30.5cm) from the
finished floor, and a minimum of 6” (15cm) from any vertical surface if installed in the ceiling.
1. The recess box provided with the heater is designed for attachment between studs placed on 16” (40.6cm) centres. If different spacing exists, construct frame tosuit the box in order to avoid any vibration and noise caused by loose mounting (Fig. 2a).
2. Note orientation of box (“TOP” shown on recess box) and secure to studs using four holes provided on side flanges, ensuring these flanges are flush with finished surface of wall or ceiling (Fig. 2b).
Surface Installation
1. Secure optional surface mount box (Part No. RFP8D) by angling screws through holes provided in rear of surface box into studs or finished surface.
2. Position surface box into recess box and secure with four screws provided in parts bag of surface box.
Series RFI-D for wall or ceiling mounting
Fig.1
GROUND SCREW
FRONT PANEL (GRILLE) & TRIM FRAME
HEATER ASSEMBLY
RECESS BOX
Fig. 2
(a) (b)
19 3/4” (50cm)
MIN. 12” (30.5cm)
14 1/4” (36cm)
SIDE FLANGES
FINISHED WALL
SURFACE
15”
(38cm)
FINISHED FLOOR
7/8” (22MM) DIA. KNOCKOUT
14 1/4” (36cm)
3 5/8” (9cm)
19 3/4” (50cm)
MIN. 12” (30.5cm)
NOTE: Dimensions are shown as size of rough opening in stud wall
Fig. 3
A
C
(A)Place frame over top of tabs. (B) Push in at bottom until frame is flush with front panel.
(C) Insert two screws to hold frame in place.
C
B
Supply Wiring and Heater Installation
1. Insert approximately 15” (38cm) of supply wire into recess box through knockout provided in upper left hand corner (Fig. 2b). Wire should be rated for a minimum of 75°C (167°F)
2. Connect power supply to terminals provided marked L1 and L2. Ground wire should be secured to green ground screw provided on side of heater assembly (Fig. 1).
3. All units are factory prewired for operation with built-in thermostat. If remote thermostat operation is required follow appropriate wiring diagram located on inside of recess box.
TIP - It is recommended that for ceiling mount applications a remote thermostat be used in order to provide superior temperature
control.
NOTE -All wiring must comply with National Electrical Code and local codes.
4. Secure heater assembly to recess box using four 8 - 18 x 5/16” screws provided. Ensure that the four speed clips are attached to heater assembly top and bottom.
Front Panel Installation
1. Remove trim frame from front panel assembly. (Fig. 3)
2. If tamperproof built-in or remote thermostat operation is required, secure the louvered door to the front panel using 2 No. 6 screws (not included) through the holes provided. The knob can then be removed and adjustment of the thermostat can be made using a slotted screwdriver through the front panel.
3. Check to see that the fan blade is free to turn and that no residue remains in the unit. Front panel can then be secured to assembly using four 8 - 18 1/4” screws provided.
Operation and Maintenance
1. Set thermostat to desired temperature and both fan and heat should come on. Note that when desired temperature is reached the fan operation will continue for a short period after the elements have de-energized in order to remove residual heat from the unit.
2. The fan motor is permanently lubricated and sealed at the factory and is maintenance free.
3. It is suggested that at the beginning of each season the front panel is removed and the wire connection condition is checked and the unit is cleaned of dust and dirt with a vacuum cleaner.
NOTE - Always open the circuit breaker to disconnect power to the unit prior to performing any maintenance or service operation.
WARNING - Should the Over Temp light come on, disconnect power to the heater or turn down the thermostat fully
counterclockwise and call a licenced electrician. DO NOT USE HEATER UNTIL PROBLEM IS DETERMINED AND FIXED.
WIRING DIAGRAM 1 WIRING DIAGRAM 2
BUILT IN THERMOSTAT (FACTORY WIRED)
S.P. “LINE” VOLTAGE REMOTE THERMOSTAT
L2
SUPPLY
L1
UNIT GND.
L
THERMAL
CUT OUT
L2
THERMOSTAT
CYCLE
3
1
FAN DELAY
2
C
CAPACITOR
L1
OFF
A
B
M
NOTE: THIS WIRING REPRESENTS THE UNIT AS
FACTORY WIRED. PLEASE CONSULT THE OTHER DIAGRAMS SHOWN AS TO WHAT OPTION IS REQUIRED. PLEASE ASSURE THAT ALL ELECTRICAL CLEARANCES ARE MET.
L2 (L-277V)
L1 (N-277V)
A
D
L2
L2 (L-277V)
SUPPLY
UNIT
GND.
L
THERMAL
CUT OUT
L2
THERMOSTAT
CYCLE
B
FAN DELAY
L1
L1
OFF
A
C
CAPACITOR
23
1
M
L1 (N-277V)
REMOTE SP STAT
A
B
D
1. MARR/TAPE WIRE LABELLED “L1” FROM THERMOSTAT
2. DISCONNECT WIRE “B’ FROM MARR CONNECTOR “B”, MARR/TAPE WIRE “B” AS SHOWN OR REMOVE FROM THERMOSTAT CONNECTOR AND DISCARD
3. CONNECT INCOMING SUPPLY “L1” TO CONNECTOR “A”
4. CONNECT LOAD SIDE OF REMOTE LINE VOLTAGE THERMOSTAT TO MARR CONNECTOR “B” AS SHOWN
5. CONNECT INCOMING POWER WIRE “L2” TO BOTH THE LINE SIDE OF REMOTE WALL THERMOSTAT AND WIRE ATTACHED TO BUILT IN THERMOSTAT WIRE LABELLED “L2” AS SHOWN.
WIRING DIAGRAM 3
D.P. “LINE” VOLTAGE REMOTE THERMOSTAT
L2
SUPPLY
L1
L1
OFF
CAPACITOR
D
M
UNIT GND.
L
THERMAL
CUT OUT
L2
THERMOSTAT
CYCLE
B C
23
1
FAN DELAY
1. MARR/TAPE WIRE LABELLED “L1” FROM THERMOSTAT
2. DISCONNECT WIRE “B’ FROM MARR CONNECTOR “B”, MARR/TAPE WIRE “B” AS SHOWN OR REMOVE FROM THERMOSTAT CONNECTOR AND DISCARD.
3. CONNECT LOAD SIDE OF REMOTE WALL THERMOSTAT TO MARR CONNECTORS “A” AND “B” AS SHOWN IN DIAGRAM.
4. CONNECT INCOMING POWER WIRE “L2” TO BOTH THE LINE SIDE OF REMOTE WALL THERMOSTAT AND THE WIRE ATTACHED TO BUILT IN THERMOTAT WIRE LABELLED “L2”
5. CONNECT THE OTHER INCOMING SUPPLY LINE TO THE LINE SIDE OF REMOTE WALL THERMOSTAT.
CYCLE
OFF
L2 (L-277V)
L1 (N-277V)
REMOTE D.P. STAT
A
B
CUSTOMER WIRING
CUSTOMER SUPPLIED
FACTORY SUPPLIED
L
ON 240/208V UNITS ONLY
CATALOGUE NO. MOTOR CAPACITOR FAN BLADE ELEMENT CUT-OUT FAN DELAY THERMOSTAT FRONT PANEL KIT
RFI815D31 RFIFPA
RFI815D31W RPIFPW
RFI820D31 RFIFPA
RFI820D31W RPIFPW
RFI820D41 RFIFPA
RFI820D41W RPIFPW
RFI830D31 RFIFPA
RFI830D31W RPIFPW
RFI830D41 RFIFPA
RFI830D41W RPIFPW
RFI840D21 RFIFPA
RFI840D21W RPIFPW
RFI840D31 RFIFPA
RFI840D31W RPIFPW
RFI840D41 RFIFPA
RFI840D41W RPIFPW
RFI848D31 RFIFPA
RFI848D31W RPIFPW
00013008RP
00013005RP
2000260600RP
3200070100RP
3200070400RP
3200070100RP
00033002RP
2000260200RP
2000260600RP 00033001RP
2000260600RP
2000260200RP 00033002RP
00033001RP
00013001RP
00013002RP
00013004RP
00013002RP
00013008RP
00013004RP
00033001RP
00033002RP
00033001RP
REPLACEMENT PARTS
00010034RP 00009112RP 13678001RP
2000260200RP 00013007RP
2000260600RP 3200070100RP
3200070400RP
3200070100RP
3200070400RP
7200610100 REV10