Dimplex RCH5031W Installation Instructions Manual

Ceiling-mounted Heater RCH5031W
IMPORTANT INSTRUCTIONS
When using electrical appliances, basic precautions should always be followed to reduce the risk of re, electric shock and injury to per­son, including the following:
1. Read all instructions before using this heater.
2. The heater is hot when in use. To avoid burns, do not let bare
skin touch hot surfaces. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least a 3 ft. (1 m) from the front of the heater and keep them away from the sides.
3. Wiring procedures and connections should be in accordance
with the National Electric Code (NEC & CEC) and local codes.
4. Extreme caution is necessary when any heater is used by or
near children or invalids and whenever the unit is left operating
and unattended.
5. Do not operate any heater after it malfunctions. Disconnect
power at service panel and have heater inspected by a certied
electrician before reusing.
6. To disconnect heater, turn off power to heater circuit at main dis- connect panel.
7. Do not use outdoors.
8. Use this heater only as described in this manual. Any other use
not recommended by the manufacturer may cause re, electric shock, or injury to persons.
9. A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint or ammable liquids are used
or stored.
10. This heater is hot when in use. To avoid burns, do not let bare
skin touch hot surfaces. Keep combustible materials such as: furniture, pillows, bedding, papers, clothes and curtains away from heater.
11. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or re, or damage the heater.
12. To prevent a possible re, do not block air intake or exhaust in any manner.
SAVE THESE INSTRUCTIONS
Figure 2
MINIMUM
6" (15.3 cm)
MINIMUM
8' (244 cm)
Installation Instructions
Figure 1
Mounting Bracket
Electrical Knockouts
Securing Screws
WARNING: Wiring procedures and connections should be in ac-
cordance with the National Electric code (NEC) and local codes.
or other ammable vapors and liquids in the vicinity of the heater.
CAUTION: The heater should be mounted for DOWNWARD dis-
charge only.
CAUTION: High temperature, risk of re, keep electrical cords, drapery, furnishings, and other combustibles at least 3 feet (0.9m) from the front of the heater and away from the side and rear.
1. Unpack the heater from the carton.
2. With the unit outlet pointing up, using the provided allen key,
remove the 4 screws to remove the grill box off of the unit.
3. Flip the unit over and loosen 1 screw to remove the mounting
bracket.
4. Determine the desired location, keeping in mind the minimum
clearances indicated in Figure 2.
5. Secure the mounting bracket to the ceiling.
CAUTION: The ceiling and mounting hardware must have ad­equate strength to support the heater. Attachment to a rm support is a necessity.
6. Loosen 2 screws to remove the wiring compartment cover. (Fig-
ure 1)
7. Remove the desired knockout from the terminal box.
!
NOTE: It is only necessary to remove the knockout(s) that will feed the power supply wiring, keeping in mind the heater mounting location and supply wire location.
8. Hang the heater from the hooked edge of the mounting bracket.
9. Connect power supply the wires to the wires in the unit - black
(L1) and white (L2). Ground wire should be secured to the green
wire provided inside of the heater.
WARNING: All wiring must be installed by a certied electrician
according to the electrical safety. The ceiling heater must be ground-
ed in accordance with all national and local building codes.
10. Replace the wiring compartment cover and replace with the 2
screws.
Wiring Compartment Cover
Grill Box
7214060100R01
11. Swing the heater upwards to secure the opposite side of the
heater to the bracket and secure with previously removed
screws.
12. Replace the grill box.
WARNING: TO PREVENT THE RISK OF FIRE OR INJURY, DO
NOT OPERATE THE HEATER UNLESS IT IS FULLY ASSEM­BLED.
Wiring Diagram
M
CUTOUT
WALL STAT
L1
NOT PROVIDED
THERMOSTAT
L1
L2
G
Operation Instructions
WARNING: This heater must be properly installed before it is
used.
1. Prior to energization remove all construction dirt (plaster, saw-
dust, etc.) from interior and exterior of heater.
2. Adjust the thermostat with a thin at head screwdriver. This unit is controllable from a line voltage wall thermostat or a low volt­age thermostat through a relay, refer to the wiring diagram.
Dimplex ceiling heaters are designed and tested for safe and trou­ble-free operation. All Dimplex ceiling heaters are protected against overheating by a built-in thermal cutout. Free airow throughout the heater is extremely important for the most efcient operation of the heater. Restricted airow may cause the thermal overload protector to cycle the heater “ON and OFF”. A cycling heater will not supply sufcient heat to the room.
CAUTION: Avoid direct contact of paper, fabric, or furniture with
heater.
Maintenance Instructions
WARNING: Always disconnect power at the circuit breaker to the
unit prior to performing any maintenance or service operation.
CAUTION: Allow adequate time for the element and body casing
to cool before attempting to work on the heater.
It is suggested that the heater be inspected regularly, for cleanliness of the fan intake and exhaust grilles, to ensure optimal performance is maintained. The grilles can be cleaned either by vacuuming off all dust and dirt or, washing the grille box in warm, soapy water and allowing to dry thoroughly before reinstalling. Once cleaning is com-
plete replace the grille and restore power.
WARNING: TO PREVENT THE RISK OF FIRE OR INJURY, DO
NOT OPERATE THE HEATER UNLESS IT IS FULLY ASSEM­BLED.
At least at yearly intervals the wire connection condition should be inspected to ensure full electrical continuity and optimal performance is maintained.
WARNING: The user can perform cleaning ONLY. All other servic-
ing should be performed by qualied service personnel.
Warranty
The Manufacturer warrants the RCH series ceiling heaters and com­ponents of the enclosed product against any defect in material or workmanship for a period of one year from the date of purchase. In full satisfaction of any claims under this Warranty the Manufacturer will repair or replace without charge, in its factory or in the eld as it alone may decide, any parts which in its opinion are defective.
The Manufacturer shall not be responsible for any transportation or shipping costs in relation to such repair or replacement except as specically assumed by it. Misuse of this product or repairs by per-
sons other than the Manufacturer’s authorized personnel without the
Manufacturer’s written approval, will void this Warranty. This Warranty is in lieu of all other warranties or conditions whether
express or implied including but not limited to those of merchant­ability or tness for purpose and shall constitute the sole remedy of the Purchaser and the sole liability of the Manufacturer in respect of the sale of the product, whether in the nature of breach or breach of fundamental term, or of negligence or otherwise.
The Manufacturer shall not be liable for any special, indirect or con­sequential damages or for any damages resulting from removal or replacement of a heater subject to warranty claim without the Manu-
facturer’s authorization.
This Warranty is transferable by the original consumer purchaser of the product. Any claims under this Warranty must be submitted in writing to the Service Manager, Dimplex North America Ltd., 1367 Industrial Rd., Cambridge, Ontario N1R 7G8, Canada.
Replacement Parts
Cutout .................................RCH-CUTOUT-RP
Fan Blade ..................................RCH-FAN-RP
Motor ...................................RCH-MOTOR-RP
Housing Cover ............................RCH-COVER-RP
Thermostat ........................RCH-THERMOSTAT-RP
1367 Industrial Road Cambridge ON Canada N1R 7G8 1-888-346-7539 www.dimplex.com
In keeping with our policy of continuous product improvement, we reserve the right to make changes without notice. © 2015 Dimplex North America Limited