Dimplex RBF24DLX, RBF24DLXWC Owner’s Manual

Owner’s Manual
Revillusion™ Electric Fireplace/
Fireplace Insert
Model RBF24DLX (6909990100)
Model RBF24DLXWC (6909990200)
IMPORTANT SAFETY INFORMATION: Read this manual rst before attempting to install or use the Revillusion™ Electric Fireplace. Always comply with the warnings and safety instructions contained in this manual to prevent personal injury or property damage.
To view the full line of Dimplex products, visit www.dimplex.com
7215770100R00
Table of Contents
Welcome .............................................................3
IMPORTANT INSTRUCTIONS ...........................4
Specications ......................................................6
Installation ...........................................................7
Electrical ............................................................10
Operation ...........................................................16
Maintenance ......................................................20
Warranty ...........................................................22
Technical Support ............................................ 24
SAVE THESE INSTRUCTIONS
Conventions used in this manual:
!
NOTE: Procedures and techniques considered important enough to
emphasize.
CAUTION: Procedures and techniques which, if not carefully followed,
will result in damage to the equipment.
WARNING: Procedures, precautions, and techniques which, if not
carefully followed, will expose the user to the risk of re, serious injury, or death.
2 www.dimplex.com
Welcome
MOD
MODEL / CAT NO
SERIAL NO
Thank you for purchasing a Revillusion™ Electric Fireplace by Dimplex. Please use our convenient online registration page to record your model and serial numbers for future reference at:
www.dimplex.com/register
Model Number
Serial Number
CAUTION: Read all instructions and warnings carefully before starting
installation. Failure to follow these instructions may result in a possible electric shock or re hazard and will void the warranty.
NO NEED TO RETURN TO THE STORE
Questions with operation or assembly? Require Parts Information?
Product Under Manufacturer’s Warranty?
Contact us at: www.dimplex.com/customer_support
For Troubleshooting and Technical Support
OR Toll-Free 1-888-346-7359
Monday to Friday 8:00 a.m. to 4:30 p.m. EST
In order to better serve you, please have your model and serial numbers
ready or register your product online before calling (see above).
3
IMPORTANT INSTRUCTIONS
Basic Precautions
When using any electrical appliance, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons. These precautions include:
Read all instructions before using the RevillusionTM Electric Fireplace.
DANGER: High temperatures
may be generated under certain abnormal conditions. Do not partially or fully cover or obstruct the front of the replace.
This fireplace is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. The trim around the heater outlet becomes hot during heater operation. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 3 feet (0.9 m) from the front of the fireplace.
Extreme caution is necessary when the fireplace is used by or near children or invalids and whenever the fireplace is left operating and unattended.
Always turn off the fireplace when it is not in use.
Do not operate the fireplace after it malfunctions, has been dropped, or damaged in any manner. Disconnect power at the service panel and have the fireplace inspected by a reputable electrician before using.
Do not use this fireplace outdoors.
Never locate the fireplace where it
may fall into a bathtub or other water container.
Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock, or fire, or damage the fireplace.
To prevent a possible fire, do not block air intakes or exhaust in any manner
To disconnect the heater, turn the controls to OFF and turn off the power to the heater circuit at the main disconnect panel.
All electrical heaters have hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored.
Do not modify this fireplace. Use it only as described in this manual. Any other use may cause fire, electric shock, or injury to persons.
Do not burn wood or other materials in this fireplace.
Disconnect all power coming to the fireplace at the main service panel before performing any cleaning or maintenance.
When transporting or storing the fireplace, keep it in a dry place, free from excessive vibration, and store to avoid damage.
NOTE: Changes or modications
!
not expressly approved by the party responsible for compliance could void user's authority to operate the equipment.
4 www.dimplex.com
IMPORTANT INSTRUCTIONS
Special Precautions
WARNING: Remote control
contains a small battery. Keep away from children. If swallowed, seek medical attention immediately.
WARNING: Do not install battery
backwards, charge, put in re or mix with used or other battery types as it may explode or leak causing injury.
WARNING: Do not open the unit.
There is a risk of electric shock. There are no user-serviceable parts inside.
CAUTION: Always use a qualied
technician or service agency to repair the electric replace.
FCC Compliance
CAUTION: This unit has been
tested and found to comply with the limits for Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This unit generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception, which can be
determined by turning the unit OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the unit and the receiver.
• Connect the unit into an outlet on a
circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This unit complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This unit may not cause harmful interference, and (2) this unit must accept any interference received, including interference that may cause undesired operation.
FCC CAUTION: Any changes or
modications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
NO USER-SERVICEABLE PARTS INSIDE
5
Specications
The Revillusion™ Electric Fireplace offers an alternative to a wood or gas fireplace. It can give your existing fireplace new life or transform a cabinet or media center of your own into a stunning focal point.
NOTE: A 15 Amp circuit is
Electrical
Volts 120 V
Amps
Watts
Wiring Plug-in replace,
Bulb Type LED
Approvals
60 Hz
11.25 A @ 25o C
12.50 A @ 0o C
1350 W @ 25o C 1500 W @ 0o C
hard wire optional
Dimensions
RBF24DLX RBF24DLXWC
Width 24 1/4"
640 mm
Height 22 7/8"
581 mm
Depth 12 1/8"
307 mm
Operation Temperature
o
-4
to 104o F (-20o to 40o C)
24 1/4" 640 mm
22 7/8" 581 mm
12 1/8"
307 mm
!
required. A dedicated circuit is preferred, but not essential in all cases. A dedicated circuit will be required if, after installation, the circuit breaker trips or the fuse blows on a regular basis when the heater is operating. Additional appliances on the same circuit may exceed the current rating of the circuit breaker.
Unpacking the Unit
The unit comes packed with a protective sheet covering the front of the unit. This sheet is intended to prevent dust and debris from entering during construction. This sheet is designed so that it can be partially removed to complete the wiring and unpacking and can be reinstalled until the final installation is complete.
The log set was installed on the grate and the grate permanently fixed to the fireplace at the factory.
Carefully remove the packaging from around the log set. Make sure the wires from the log set are connected securely to the grate box.
WARNING: Electrical outlet wiring
must comply with local building codes and other applicable regulations to reduce the risk of re, electric shock, or injury to persons.
6 www.dimplex.com
CAUTION: The Realogs® contain
LEDs to create a unique pulse and glow effect. Handle the log set carefully. They are fragile and can crack or break if dropped.
Installation
Framing
1. The Revillusion
Fireplace Insert does not require any special venting.
2. To build the rough-in opening, follow
the framing dimensions below.
TM
Electric Fireplace/
RBF24DLX RBF24DLXWC
A 12 1/2" (318 mm) 12 1/2" (318 mm)) B 24 5/8" (626 mm) 24 5/8" (626mm) C 22 3/8" (568 mm) 22 3/8" (568 mm)
D 22 1/8" (562 mm) 22 1/8" (562 mm) E 12 1/8" (307 mm) 12 1/8" (307 mm) F 23 3/8" (595 mm) 23 3/8" (595 mm) G 25 1/4" (640 mm) 25 1/4" (640 mm) H 19" (483 mm) 19" (483 mm)
I 22 7/8" (581 mm) 22 7/8" (581 mm)
J 47 3/4" (1213 mm) 47 3/4" (1213 mm)
K 33 3/4" (857 mm) 33 3/4" (857 mm) L 33 3/4" (857 mm) 33 3/4" (857 mm)
!
NOTE: The materials used for
the nished surround must be cut to precise dimensions (dimensions B & C) as the 1/4" (0.6 cm) self trimming ange is only to create a nished appearance.
K
I
C
D
A
Rough-In Framing Dimensions Fireplace Dimensions Rough-In Corner Dimensions
7
B
E
H
J
F
G
L
Installation
Front Glass Installation Method
1. Before installing the front glass
installation, remove the hole caps from the fireplace.
2. Make sure all hardware has been
included in package prior to starting.
x2 x2 x2 x4
3. Install hardware items A and B onto
front glass.
4. Install brackets onto fireplace with
screws C.
5. Place front glass into fireplace and
secure with screw D
6. Install top trip piece.
8 www.dimplex.com
Loading...
+ 17 hidden pages