Dimplex QM050RF, QM070RF, QM100RF, QM125RF, QM150RF Operating Manual

OPERATING MANUAL
Quantum Series Heater
Models: QM050RF / QM070RF / QM100RF
QM125RF / QM150RF
- 1 -
08/82862/0 ISSUE: 2 Series: G.6
IMPORTANT
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE. Note also the information presented on the appliance
Warnings in this document are identified by a warning triangle against a grey backgound. Keywords at the start of a warning indicate the type and seriousness of the ensuing risk if measures to prevent the risk are not taken.
The following keywords are defined and can be used in this document:
○ DANGER indicates a hazardous situation which, if not avoided, will result in
death or serious injury.
○ WARNING indicates a hazardous situation which, if not avoided, could result
in death or serious injury.
○ CAUTION indicates a hazardous situation which, if not avoided, could result in
minor to moderate injury.
○ NOTICE is used to address practices not related to personal injury.
CAUTION
FAILURE TO FOLLOW THESE INSTRUCTIONS MAY CAUSE INJURY AND/OR DAMAGE AND MAY INVALIDATE YOUR GUARANTEE
IMPORTANT SAFETY ADVICE
When using electrical heaters, basic precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons, including the following:
IMPORTANT – The wall bracket supplied with the heater must be used. IMPORTANT – All packaging should be disposed of in an appropriate manner.
OVERHEATING WARNING
WARNING - In order to avoid overheating, do not cover or obstruct the heater. Do
not place material or garments on the heater, or obstruct the air circulation around the heater, for instance by curtains or furniture, as this could cause overheating and a fire risk. NEVER cover or obstruct in any way the heat outlet slots at the top of the heater or the air outlet slots in the base of the heater.
WARNING - THE SURFACES ON THIS HEATER CAN BE HOT.
The heater carries a warning ‘DO NOT COVER’ to alert the user to the risk of fire that exists if the heater is accidentally covered.
CAUTION - Some parts of this product can become very hot and cause burns.
Particular attention has to be given where children and vulnerable people are present.
For your safety this heater is fitted with a thermal cut-out. In the event that the product overheats for some reason, the cut-out prevents excessive temperatures on the product by cutting the power to the heater. Once the heater has cooled down, it will reset automatically, it will continue to cycle on and o automatically until the reason for overheating is removed.
The display screen may flash red to indicate the product has overheated. To reset the display, remove the obstruction and hold Enter for 10 seconds.
- 2 -
SUITABLE APPLICATIONS
WARNING - This heater is suitable for normal dwelling purposes and should not be
used in any other type of environment. This product should only be used in the country where it was purchased from by a recognised commercial retailer. Do not use outdoors.
SERVICING AND REPAIRS
WARNING - Servicing and product repairs should only be undertaken by the
manufacturers approved service agent or a similarly trained or qualified person, using only exact manufacturer approved spare parts. PLEASE NOTE: Household dust, lit cigarettes, candles and oil burners, combined with the convection eect of electric heaters can cause significant soot deposits to build up on the surface directly above and to the sides of the heater. This is not a fault of the heater. Extensive burning of candles or smoking in the operating environment of this product can produce heavy discolouration within a few months of use.
OPERATING WARNINGS
IMPORTANT: Remember to observe all safety warnings and precautions when
operating the heater on the automatic or timer modes, either attended or unattended since a fire risk exists when the heater is accidentally covered, obstructed or displaced.
CAUTION: Do not use if either of the heater’s mains power leads become damaged. If
the supply cord is damaged it must be replaced by the installer or an approved Dimplex service partner.
Do not sit or stand on the heater. Ensure minimum clearances between the heater and other objects / surfaces are
maintained.
ELECTRICAL INSTALLATION
WARNING - Minimum clearances and IP zone requirements must be adhered to in
accordance with the current wiring regulations.
Mains cables are not provided with this heater.
WARNING - The electrical installation of this heater must be carried out by a
suitably qualified or trained electrician, and be in strict accordance with current wiring regulations.
The peak supply must be connected via a switched fused spur with a fuse rated suitably for the appliances flex, the o-peak supply, via a 20A double pole isolated switch. In both instances a plug and socket arrangement MUST NOT be utilised. The contact separation to be a minimum of 3mm.
Failure to follow these instructions will mean that the manufacturer’s instructions have not been adhered to. THERE ARE NO EXCEPTIONS.
• This heater must be earthed
• Not suitable for connection via a plug top
• Do not locate the heater immediately above, below or in front of a fixed electrical point i.e. socket outlet.
This appliance is intended for installation to a single phase supply only and is not suitable for connection to 3 phase supplies.
- 3 -
ELECTRICAL INSTALLATION continued
The heater is not fitted with a mains cable, this should be fitted by the installer. Cable type (minimum size) H05VV-F 1.5mm² three core for peak and 2.5mm² three core for o-peak for connection to the fixed wiring of the premises through suitable isolation devices positioned adjacent to the heater. The supply circuits to the heater must incorporate a double pole isolating switch having a contact separation of at least 3mm.
In installation the supply cord must be cut to the appropriate length for the electrical connection point. Excess cable should not be inserted or stored behind the heater.
If, during reassembly of the heater, a part of the thermal insulation shows damage or deterioration, it should be replaced by an identical part.
WARNING: All electrical connections to the terminal block must be secure to prevent
risk of ignition. Tighten to 2 Nm.
CHILD SAFETY
WARNING - Fixing kit screws are a potential choking hazard. WARNING - This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of appliance by a person responsible for their safety.
This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
Children of less than 3 years should be kept away unless continuously supervised.
Children aged from 3 years and less than 8 years shall only switch on/o the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children aged from 3 years and less than 8 years shall not regulate and clean the appliance or perform user maintenance.
WARNING - KEEP BATTERIES OUT OF REACH OF CHILDREN
WARNING - Packaging should be disposed of responsibly as the EPS used could
be a potential choking hazard for children.
- 4 -
i
This document is customer property and is to remain with this unit.
These instructions do not cover all the dierent variations of systems nor does it provide for every possible contingency to be met in connection with installation.
WARNING: EARTHING
This appliance must be earthed in accordance with the manufacturers recommendations and in accordance with IEE regulations for electrical equipment.
Failure to adequately earth the appliance can result in electrical shock causing severe personal injury or death.
WARNING: HAZARDOUS VOLTAGE
Disconnect all power to unit before installing or servicing.
Hazardous voltage can cause severe personal injury or death.
WARNING: ACCESS TO LIVE PARTS
If the supply cables to the appliance are damaged in anyway, they must be immediately replaced by a competent person in order to avoid electrocution which could cause severe personal injury or death.
WARNING
The appliance must be securely fixed to the wall. The installed appliance could weigh up to 165kg and if it falls o the wall it could cause severe personal injury or death. It is the responsibility of the installer to ensure that the appropriate wall fixing is used and that the floor is capable or bearing the full weight.
- 5 -
WARNING
To avoid a fire hazard the cardboard insert within the heater core must be removed before the heater is switched on. Also ensure all polystyrene packaging is removed before the heater is operated. Leaving combustible packaging in the appliance could lead to fire and cause severe personal injury, death and damage to property.
CAUTION
The appliance is very heavy (up to 50kg) and care should be taken when handling during installation to reduce risk of muscular or skeletal injuries.
CAUTION
The appliance should not be repeatedly switched on/o by an external room thermostat as this could lead to failures of the electronic controller and may invalidate the guarantee – further clarification SHOULD BE SOUGHT FROM GDC HELPDESK.
i
CAUTION
During the first 48 hours of operation rooms must be well ventilated as the heater will produce a smell. Young children, caged birds, or persons with respiratory complaints must not remain in close proximity to the appliance during the first 48 hours or operation.
It is important that the appliance bricks are dry and free from mould growth. Wet or mouldy bricks can lead to an unpleasant odour and or steam being generated by the appliance which could upset the customer.
- 6 -
- 7 -
Energy Related Product Directive
This product meets the Ecodesign requirements for an electric storage local space heater. Commission
Regulation (EU) 2015/1188.
Model Identifier(s): QM050RF QM070RF QM100RF QM125RF QM150RF
Heat Output
Nominal heat output Pnom 0.50kW 0.75kW 1.00kW 1.25kW 1.50kW
Minimum heat output (indicative) Pmin
Maximum heat output Pmax,c 0.90kW 1.20kW 1.50kW 1.70kW 2.00kW
Auxiliary electricity consumption
At nominal heat output elmax 0.00 0.00 0.00 0.00
At minimum heat output elmin
In standby mode elSB
Type of Heat input, for electronic storage local space heaters only
Electronic heat charge control with room temperature feedback
Fan assisted heat output Yes
Type of heat output / room temperature control
0.00 0.00 0.00 0.00 0.00
0.00
0.00 0.00 0.00 0.00 0.00
0.000 0.000 0.000 0.000 0.000
Yes
Electronic room temperature control plus week timer
Contact details
Glen Dimplex Heating and Ventilation Millbrook House, Grange Drive, Hedge End, Southampton, SO30 2DF Tel: 0344 879 3588 This product meets the Ecodesign requirements for an electric storage local space heater. Commission Regulation (EU) 2015/1188.
Yes
Technical Details
Model Identifier(s): QM050RF QM070RF QM100RF QM125RF QM150RF
Input rating +5% / -10% 936/1020W 1435/1560W
Boost Output 230/240V~ 312/340W 478/520W 681/740W 847/920W 1008/1100W
Rated Charge Period: 7.7 - 7 Hours 7.7 - 7 Hours 7.7 - 7 Hours 7.7 - 7 Hours 7.7 - 7 Hours
Max Storage Capacity 7.2kWh 10.9kWh 15.4kWh 19.3kWh 23.1kWh
2042/2220W
2540/2760W
3024/3300W
Fan Wattage 11W 11W 11W 11W 11W
UI Wattage 0.5W 0.5W 0.5W 0.5W 0.5W
Sound Level dB
(measured in test chamber)
Energy Cell Packs Required (047243) 4 6 8 10 12
Height (mm) 730 730 730 730 730
Width (mm) 580 703 865 1069 1069
Depth (mm) 185 185 185 185 185
27 29 32 30 31
- 8 -
All Models
Controls
Controller UI
Digitally controlled, Electronic Thermostat accurate to (±0.2°C).
Timer modes:
7 Day Programmable User Timer, Out All Day, Home All Day
Continuous heat modes:
Frost Protect
Additional Modes:
Away, Boost, Setback
Graphical display with RGB backlight
Tactile buttons with audio feedback
User replaceable battery (Coin-Type)
Open window detection, Adaptive Start, Advance Time Period
Wide SP range (7-30°C)
Automatic Charge Control
History / Reporting Screens
Boost Mode, User Adjustable
Heat Demand % Adjustment
Child Lock & Heater Lock (PIN-based)
Electronic overheat protection.
Safety
Additional electromechanical overheat protection. LVD and EMC compliance.
IP Rating IPX4
Battery 3.3V coin cell battery to backup real time clock. Battery life > 5 years.
Supply
Colour / Finish
1/N/1/N/PE ~230-240V (Twin Supply) 230-240V / 50Hz Class I 1/N/PE ~230-240V (Single Supply) 230-240V / 50Hz Class I
Trac White (RAL 9016), Grille RAL7035
Storage Core High-density bonded magnetite energy cells
Approvals CE & BEAB
Guarantee 2 Years. 10 Years extended available with registration.
Country of Origin United Kingdom
Manufacturer
- 9 -
Glen Dimplex Heating & Ventilation (GDC Group Ltd)
Product Clearances
WARNING:
DO NOT PLACE OBJECTS WITHIN 300mm OF THE FRONT OF THE HEATER AND 150mm EITHER SIDE
250 mm
150
mm
150
mm
300 mm
Single Supply
It is important to be aware of how your Quantum storage heater has been installed electrically. If you Quantum has only one electrical connection, it must be carefully configured to work with your o-peak electricity tarri.
Available fixed charge times must be manually programmed into the heater to tell it when to charge; no external timers or contactors are needed. Up-to 4 digital charge times can be set.
If charge times are not programmed into the heater, the default times will be used which are set-up by default to support dual-supply installations: 00:00 – 00:00 or 24h charge window.
A 24h charge window in a single supply installation will cause the heater to charge continuously,
including times when o-peak electricity is not available, resulting in larger bills.
NOTE:
If electricity tarri charge times have changed, the digital charge times in the heaters settings must be checked to ensure they match.
- 10 -
First Time Power-On
A setup wizard will display when the product is powered on for
the first time. This will set the following:
Time, Date, Daylight Savings Time
Sound On/O
For information on using the Heaters controls, refer to page 10.
The Heater will then take the User to the Home Screen with the
‘Out All Day’ Timer Mode active
This product is Dimplex Control capable * **.
Important
During initial heat-up, some odour
may be emitted due to the newness of
materials used in manufacture. This is
normal and will disappear after a short
period of use. It is however advisable to
keep the room well ventilated.
Control and monitor your heating and hot water with Dimplex Control. Group heaters into zones to easily control and
track their energy usage. Any time. Anywhere.
Search for Dimplex Control on your device’s app store.
*Requires additional hardware. Sold seperately. Visit Dimplex.co.uk for more information.
**A Dimplex Hub is required for this product to connect to Dimplex Control. For instruction on setting up Dimplex
Hub, please refer to the manual. Manuals can be downloaded at Dimplex.co.uk.
- 11 -
Operation
WARNING: FAILURE TO FOLLOW THESE OPERATING INSTRUCTIONS MAY RESULT IN INJURY AND/OR DAMAGE
The controls are located on the top of the heater consisting of a display screen and three buttons and a Dial.
1
Display Screen
2
‘Menu’ Button
3
‘Back’ Button
4
‘Selector Dial’
5
‘Enter’ Button
6
‘Advance’ Button
7
Heating Status
1
Out All Day
Heating ON
6
ADVANCE
MENU
BACK
4
3
7
The heater is fitted with an adjustable thermostat enabling the room temperature to be controlled. The minimum
room temperature is 7°C. The maximum temperature is set to 30°C by default. A temperature of 21°C is a common
comfortable room temperature.
NOTE:
Your heater may produce some noise during operation. This noise is caused by the low noise fan and expansion and contraction of the metalwork as it changes temperature, and is normal for this type of product. Whilst the noise produced is usually very quiet, certain environmental factors can make it more noticeable, such as hard flooring or minimal furnishings.
2
NOTE:
Should the heater fail to operate, this may be due to the room temperature being higher than the thermostat setting.
5
- 12 -
The heater controls can be easily adjusted by using the Dial and buttons on the User Interface.
1. The Home Screen shows the options available at each stage of
adjustment. Here the current target room temperature is displayed along
with the mode of operation. Any use of the Advance function will be
User Timer
displayed here, and pressing the Dial will show the functions which are
enabled.
The currently active mode of operation is displayed at the top of the
screen e.g. ‘Out All Day’ timer.
When the heater is in a timer profile and trying to achieve or maintain a room temperature, ‘Heating On’ will be
displayed, otherwise, ‘Heating O’ will be displayed. The words ‘Heating On / O’ will not be displayed in a manual
mode of operation
When the controller buttons have not been pressed for a long period of time, the display will ‘sleep’ and the text will
disappear. The heater is still on and active in whatever Mode it was set to.
2. Menu - Displays the Main Menu;
- Boost – Activate Boost Mode
- Modes - Set the mode of operation.
- Settings – Time/Date, Temperature units etc.
21
Heating ON
°
C
3. Back returns to the previous screen.
4. Rotate the Dial to navigate through the menus and adjust the required room temperature on the main
screen. The screen colour changes based on the temperature selected, showing deep blue through to bright
red.
5. Press the Dial to enter sub menus and to confirm actions.
6. The Advance button is only used when a Timer Mode is active, it allows the timer schedule to be changed
temporarily by forcing a ‘Heating On’ period to begin or end early.
- 13 -
Timer Modes
Timer Modes oer the most ecient mode of operation for a predictable heat demand. Additional functions such as
Advance and Boost allow the User to make temporary adjustments to timer schedules for a more flexible operation.
Each timer is broken down into 4 definable ‘Heating On’ time periods and temperatures per day, for each day of
the week. Each day consists of a 24-Hour period, starting and finishing at midnight.
When the heater is in a timer profile and trying to achieve or maintain a room temperature, ‘Heating On’ will be
displayed. Otherwise, ‘Heating O’ will be displayed.
It is possible to change the Target Temperature of a ‘Heating On’ period when that period is active. This will
temporarily adjust the Target Temperature for just that instance and will not permanently modify the settings for
the timer in use.
User Timer
°
21
Heating ON
NOTE:
If Adaptive Start is enabled, the heater will maintain the room at the required temperature for the duration of the heating period. To achieve this, the heater will begin heating the room before the start of the heating period to ensure the room is at the required temperature when the period starts.
If Adaptive Start (AS) is disabled, the heater will not operate until the beginning of the heating period. This should be taken into consideration when setting the heating periods.
C
ADVANCE
MENU
BACK
See page 22 for instruction on enabling/disabling Adaptive Start.
- 14 -
Available Timer Modes
To choose a timer mode, press Menu from the home screen. Rotate the Dial to highlight ‘Modes’, then press Dial to
select. ‘Timer Mode’ should be highlighted, press the Dial to select.
Manual
ADVANCE
Main Menu
ADVANCE
Modes
ADVANCE
Boost
Timer Mode
Frost Protect
MENU
BACK
21
°
C
MENU
BACK
Mode
Settings
MENU
BACK
A list of Timer Modes will be shown. Their default settings are shown in the table below.
Period 1 Period 2 Period 3 Period 4
User Timer 06:30 – 09:30 21 °C 11:00 – 13:00 21 °C 15:00 – 17:00 21 °C 18:00 – 22:00 21 °C
Home All Day 08:00 – 21:00 21 °C 00:00 – 00:00 00:00 – 00:00 00:00 – 00:00
Out All Day 07:00 - 8:30 21 °C 17:30 - 22:00 21 °C 00:00 - 00:00 00:00 - 00:00
Away Mode
Away Mode does not operate in the same way as the other Timers. See section ‘Away Mode’ on page 15
Highlight and select one of the available Timer Modes rotating and pressing the Dial.
Timer Mode
User Timer
Home All Day
Out All Day
Away
ADVANCE
MENU
BACK
Home All Day
Select
Modify
Preview
ADVANCE
MENU
BACK
For User Timer, Home All Day and Out All Day, three choices will be available:
Select - This option will activate the timer
Modify - This option allows the timer’s ‘Heating On’ times and Target Temperatures to be modified
Preview - This option displays the timer’s configuration. This is handy to quickly check the timer without being
able to change any values
- 15 -
Modifying a Timer Mode
Each timer is broken down into 4 definable ‘Heating On’ periods and
temperatures per day.
When Modify is chosen, ‘Heating On’ period 1 of 4 for the current day is
displayed. The current day will be highlighted. Rotate dial to highlight
‘Modify’, press dial to select. The current day will be highlighted.
User Timer
User Timer
Modify
Preview
ADVANCE
MENU
BACK
Tuesday
Period 1of4
ON: 07:30
OFF: 09:30
21 °C
ADVANCE
MENU
BACK
Select and change each option by rotating and pressing the dial.
Tuesday
Period 1of4
ON: 07:30
OFF: 09:30
21 °C
ADVANCE
MENU
BACK
Tuesday
Period 1of4
On: 07:30
OFF: 09:30
21 °C
ADVANCE
MENU
BACK
NOTE:
Once modified a Timer Mode must be selected if you want to begin using it.
Copy & Paste
To save time when modifying a Timer Mode, the Advance button can be used to copy and paste settings. Individual
heating periods from one day or every heating period from a day can be copied to another day.
Hold ENTER for 2
seconds to paste timer
Wednesday
Period 1 Pasted
ON: 07:30
OFF: 09:30
21 °C
Hold ENTER for 2
seconds to paste timer
Day Pasted
Period 1of4
ON: 07:30
OFF: 09:30
21 °C
Copy time period to other days
Copy whole day
Highlight Period
Tuesday
Period 1of4
ON: 07:30
OFF: 09:30
21 °C
Highlight Day
Tuesday
Period 1of4
ON: 07:30
OFF: 12:30
21 °C
Hold ADVANCE for
2 seconds
Tuesday
Timer Copied
ON: 07:30
OFF: 09:30
21 °C
Hold ADVANCE for
2 seconds
Day Copied
Period 1of4
ON: 07:30
OFF: 12:30
21 °C
Select day to add
time period
Wednesday
Period 1of4
ON: 07:30
OFF: 12:30
24 °C
Select day to apply
Wednesday
Period 1of4
ON: 09:30
OFF: 12:30
24 °C
- 16 -
The ‘Advance’ Function
The Advance button is only used when a Timer Mode is active and allows the timer schedule to be changed temporarily.
This button allows a ‘Heating On’ period to begin or end early.
This is useful if you are at home when you had not planned to be, or need to leave when you had planned to have the
heating on.
If the heater displays ‘Heating O’ and heat is required, press the Advance button. If the heater is in ‘Heating On’ and
heat is not required, press the Advance button and the heater will stop heating until the beginning of the next ‘Heating
On’ period.
Pre-action State Action Impact
Heating On (Timer Mode)
Heating O (Timer Mode)
Heating On (Advance Active)
Heating O (Advance Active)
Advance activated
Advance activated
Advance Deactivated
Advance Deactivated
Heating On period switched to Heating O until next scheduled ‘Comfort On’ period.
Heating O switched to Heating On until the next scheduled ‘Heating O’ period.
Heating On switches to Heating O. Appliance in following schedule set in the currently active Timer Profile
Heating O Switches to Heating On. Appliance in following schedule set in the currently active Timer Profile
Away Mode
Away Mode temporarily overrides the active mode before returning the Heater back to the previously active mode.
This is handy if you are temporarily away at the shops or on holiday and want your heating to resume as normal
operation automatically when you return.
While active, Away Mode can maintain a minimum room temperature. By default, this is set to 7 °C (frost protection
temperature). This can be modified up to a maximum of 18°C when Away Mode is activated. The heater will also
remember the last Away Mode Target Temperature defined while Away Mode is active.
The Away countdown is set in Hours, a Date and a Target Temperature.
The starting Hours and Date show current time and date. Date and Hours are set separately on the heater, making
the feature useful for popping out to the shops or going away on holiday.
The date set is the return date; therefore, Away Mode will end at 23:59 of the day before. E.g. if
a return date of 02.02.2018 is set, Away Mode will end at 23:59 on 01.02.2018.
If hours are set, this will extend away mode end from 23:59 on the day before the date set.
If only hours and no date is set, Away Mode will count from either the current time, or if a date
- 17 -
is set.
Timer Mode
User Timer
Home All Day
Out All Day
Away
ADVANCE
MENU
BACK
Return
Date/Time
Saturday
31-2-18
07:00
21 °C
ADVANCE
MENU
BACK
Return
Date/Time
Away Set
ADVANCE
MENU
BACK
Away
ADVANCE
NOTE:
The Back button can be used to end the Away Mode countdown early.
21
Until
31-02-18
07:00
°
MENU
C
BACK
Frost Protect
This mode maintains a room temperature of 7°C and should be used to provide protection against frost. The Heater
will remain in this mode indefinitely until the mode is changed by the User.
To select Frost Protect, rotate Dial to highlight ‘Frost Protect’, press Dial to select. Please note, the temperature is
not user definable.
User Timer
°
21
Heating ON
Frost Protect
C
°
7
C
Heating OFF
ADVANCE
MENU
BACK
ADVANCE
MENU
BACK
Main Menu
Boost
Modes
Settings
ADVANCE
MENU
BACK
Modes
Timer Mode
Frost Protect
ADVANCE
MENU
BACK
- 18 -
Boost Mode
Boost can be activated at any time, when the product is set to any Timer or Continuous heat mode; even if Advance
is active, this mode will provide a temporary ‘Boost’ of heat. For settings, see Boost settings on page 21.
Boost Mode can be activated from the Home Screen by pressing ‘Menu’ to access the Main Menu, then pressing the
Dial to select ‘Boost’. ‘Boost’ will always be listed as the top item on the list.
Main Menu
Boost
Modes
Settings
ADVANCE
MENU
BACK
Main Menu
Boost Temp
25 °C
Boost Time
0 Mins
ADVANCE
MENU
BACK
Boost
Boost Temp
25 °C
Boost Time
30 Mins
ADVANCE
MENU
BACK
Activating Boost will present two selectable options: Boost Temp (Boost Target Temperature) and Boost Time (Boost
Duration Countdown). The default values for these can be set in the Settings Menu.
Rotate and press the Dial to modify these values. Pressing Back will end Boost early, restoring the heater back to its
previously active mode.
The Boost Temp can be set to any value within the Heater’s Target Temperature Range setting.
The Boost Time can be increased in the following increments: 30 mins, 1 hour, 2 hours, 3 hours, 4
hours. These increments can be restricted with the Max. Boost Duration Range setting. To modify
this range, see Boost Settings on page 21.
Once the Boost Duration Countdown has reached 0, the Heater will return to the mode that was active before Boost
was activated.
- 19 -
NOTE:
If boost mode is activated and there is not enough stored core energy, peak rate energy will be used unless disabled in heat source settings.
Product Locks
Product Locks are methods of locking the heater’s controller to restrict access to functions. This can be activated
and configured via the Settings Menu. When Product Lock is activated, the heater continues to run in whichever
mode is currently active and any/all wireless communications remain active if enabled.
Child Lock
This is the simplest locking method and does not utilise a PIN code. It is toggled on/o on the heater’s controller
by pressing and holding the Back button and the Dial for three seconds.
While Child Lock is active, the heater will continue to operate in whatever mode, with whatever settings it had
before the lock was activated.
There are no exception rules with this lock, and the user can only choose to unlock the heater if they wish to change
the temperature, modes or settings.
Heater Lock (PIN Lock)
Heater Lock is the most customisable and secure lock on the heater. This allows the heater to be configured in any
way, then locked into those settings and modes.
When PIN Lock is activated, pressing the Menu button will show one item* that can be selected - ‘Unlock’. Selecting
‘Unlock’ prompts the User to complete the applicable Unlock action:
Menu
Unlock
PIN Lock
123-
Enter 4 Digit
PIN
Manual
PIN Unlocked
*Unless Boost Mode has been
enabled during UI Lock
- 20 -
PIN Lock Exceptions
It is possible to allow the ‘Advance’ and ‘Boost’ functions to be enabled/disabled when PIN Lock is active.
There are up to 4 exceptions. These exceptions include:
- Advance
• Ability to activate using the ‘Advance Button’
- Boost
• Ability to activate using the ‘hotkey’ listed in the Main Menu
• Ability to modify the Boost Temperature
• Ability to modify the Boost Duration
‘Advance Function’ Operation during PIN Lock
If Advance has been enabled during PIN Lock, the Advance button will remain active when PIN Lock is active. This
will function in the same way it would if the controls were not locked: only if the Heater is Locked into a Timer Mode.
• If Advance is enabled during UI lock, the Advance button will function as normal while the Heater is set to a Timer Mode.
• If Advance is Disabled during UI lock, the Advance button will not function.
‘Boost Function’ Operation during PIN Lock
If enabled, Boost will function in the same way as it does when PIN Lock is not active unless modification of Boost
Temperature and Boost Duration have been disabled.
Boost Temperature and Boost Duration will be set to the default values when ‘Boost’ is activated. If either of these
values have been disabled during Product lock, when the user tries to modify them the heater’s display will show the
message ‘Disabled’ and only the default value can be used. The default values can be changed outside of PIN Lock.
- 21 -
Settings
To navigate to the Settings Menu, from the Home Screen:
Main Menu
Press the Menu button to access the Main Menu. Rotate the Dial to
highlight ‘Settings’, then press the Dial. Each of the following headings
relate to an item in the Settings Menu.
Boost
Modes
Settings
Heater Lock
Set Lock
Heater (PIN) Lock can be enabled here by highlighting ‘Heater Lock’ and pressing the Dial to enter the Heater Lock
menu. Highlight ‘Set Lock’, press the Dial, enter a 4-digit PIN code, then pressing the Dial to lock the heater.
Lock Settings
Before PIN Lock is enabled, the User can select ‘Lock Settings’ to enable/disable the Advance and/or Boost functions,
as well as enable/disable modification of the Boost Temperature and Boost Duration. See below.
Settings
Heater Lock
Boost
Setback
Date / Time
Sound
Comms Adaptive
Boost Lock
Three settings can be modified within this Menu:
Enable / Disable - The ‘Boost’ Menu Item can be Enabled/Disabled while PIN Lock is active.
Temperature Rule - Modifiable Boost Temperature while PIN Lock is active
- Enable – While Boost is active, the User can modify this value as they normally would
- Disable – Default value will be loaded. When the user tries to modify the value, the UI will show
the following text: ‘Disabled’.
Duration Rule - Modifiable Boost Duration while PIN Lock is active.
- Enable – While Boost is active, the User can modify this value as they normally would
- Disable – Default value will be loaded. When the user tries to modify the value, the UI will show
the following text: ‘Disabled’
Advance Lock
Enable / Disable - This setting allows the User to Enable or Disable the Advance button while PIN Lock is
active.
- 22 -
Boost Settings
Default Boost Target Temperature
This is the default Boost Target Temperature that is used when ‘Boost Mode’ is activated.
Max Boost Duration
This is the maximum length of time that the user is able to activate ‘Boost’ for. Shown in minutes (when under
an hour) or hours (if over an hour) in the following increments: 30 mins, 1 hour, 2 hours, 3 hours, 4 hours.
The value chosen will be the max allowed when boost is activated. This is required for the Boost Duration Lock
to function.
Setback Settings
Setback is a function that only modifies Timer Mode operation. When Setback is enabled it overrides any ‘Heating O’
period to maintain a constant temperature.
This can be used to prevent the room temperature from falling below a minimum value while there is no demand for
heat (‘Heating O’).
The value of this temperature is restricted to a value between 8 and 19 °C. This is because Setback should not be treated
as a regular ‘Heating On’ period.
Date & Time Settings
This allows the Time, Date and Daylight Savings Time settings to be modified.
Sound Settings
Audio feedback when the user presses a button can be enabled or disabled here.
‘Comms’ (Communications) Settings
This allows Wireless Connectivity features to be enabled or disabled. Entering this menu item will display a list of
available communications methods to that heater.
- 23 -
Adaptive Settings
Open Window Detection
This is a global setting that can interrupt any active mode. Activating this setting enables Open Window
Detection to switch the Heater to a ‘Heating OFF’ state if it detects an open window in the room it’s operating
in.
Adaptive Start
Adaptive Start is predictive function that only modifies Timer Mode operation. This function models the
heating characteristics of the room and uses that information to pre-heat the room for only the time required
to achieve the Target Temperature by the start of the ‘Heating On’ period.
For example, with Adaptive Start o, the ‘Heating On’ time is the time that the Heater will begin to try and
achieve the Target Temperature. With Adaptive Start On, the Heater will begin to heat the room before
the User-defined ‘Heating On’ time so that the Target Temperature is achieved when the User defined the
‘Heating On’ start time.
NOTE: Adaptive Start
This is a continuously learning function and will be aected daily by changes in the heater’s environment. The heater will take into account the starting temperature of the room so pre-heating should remain accurate.
It is important that if multiple heaters are installed in one room that all heaters have the Adaptive Start (AS) function enabled. If this is not the case, heaters with AS enabled will pre-heat the room to the desired target temperature before the heaters with AS disabled attempt to output heat.
It is likely that if two heaters are required in one room, that the output from one heater may not be sucient to heat the room alone. This may cause the pre-heat time calculation to extend to a large degree if the heaters do not all have AS enabled. This may lead to heat at unwanted times and excessive wear to some heaters.
A two-hour limit is enforced on the calculation, however, if all heaters have AS enabled and pre-heating takes over one-hour, extreme environmental factors may be aecting the calculation or the heaters may be under sized for the room. Please contact us for support if your pre-heat time seems excessive.
NOTE: Open Window Detection
In environments where the product may read sudden decreases in temperature, this feature may activate in error. This can occur in drafty or poorly insulated environments as well as if the heater is undersized for the room. This feature should be disabled using the instructions above if activating for reasons other than the intended purpose. If you think that your environment is not as described here and this feature is activating, please contact our customer care team with the details on the rear page of this document.
- 24 -
Error Codes
Error codes are to be defined as a list. Each error code must be defined as a perimeter that Central Control can read.
Fault Code Description
20
20
21
Component thermistor hardware fault
22
23
24
30
32
Component overheat
33
34
40 Internal serial comms error
41 Heating element fault
50 Open window detected
51 Low water
52 Heat output disabled
53 Time loss error
54 Occupancy sensor not detected
55 Unknown error
60 Wireless communication module error
61 Hub connection error
- 25 -
Battery Replacement
IMPORTANT:
Before replacing the battery ensure the heater is isolated from the electricity supply.
NOTE:
Battery should be disposed of in an appropriate manner
This product is fitted with a replaceable battery in the controls. To replace the battery, follow the steps below:
1. Push a small flat headed screwdriver into the opening on the right hand side of the User Interface (Fig. 1) to release
the clip.
2. Lift the User Interface module out away from the heater being careful not to damage the cable
3. Unscrew the battery cover (Fig. 2) to gain access to the battery holder.
4. Use a small flat headed screwdriver to remove the battery from the battery holder and replace the battery.
5. Replace the battery access cover.
6. Push the User Interface module back into place, again avoiding damage to the cable.
Fig. 2Fig. 1
- 26 -
Important
During the initial operation, some odour may be noticed due to the newness of materials used in manufacture. This is normal and will disappear after a short period of use. It is however advisable to keep the room well ventilated
Cleaning
WARNING - ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE
CLEANING THE HEATER.
Before commencing cleaning, isolate the heater from the electrical supply and allow it to cool. The outside can be cleaned by wiping it over with a soft dry cloth. Do not use abrasive cleaning powders or furniture polish, as this can damage the surface finish.
- 27 -
Guarantee
What does a Dimplex Guarantee cover?
Dimplex products deliver reliable service for use in dwellings. All Dimplex products are individually tested before leaving the factory.
If you are a consumer and you experience a problem with your Dimplex product, which is found to be defective due to faulty materials or workmanship within the Guarantee Period, this Dimplex Guarantee will cover repair or - at the discretion of Dimplex – replacement with a functionally equivalent Dimplex product.
The Dimplex Guarantee Period is two calendar years from the date of purchase of your Dimplex product, or the date of delivery of the product, if later. The Dimplex Guarantee is conditional upon you providing the original purchase receipt as proof of purchase. Please therefore retain your receipt as proof of purchase.
If you do experience a problem with your Dimplex product please call the Helpline on +44 [0]344 879 3588 or visit https://www.dimplex.co.uk/support. For ROI please email serviceireland@glendimplex.com or call +353(0)1 842 833. We will need details of your Dimplex product, it’s serial number and a description of the fault which has occurred. You can find the model number and serial number for your Dimplex product on the heaters side. Once we receive your information and proof of purchase we will contact you to make the necessary arrangements.
If your Dimplex product is not covered by this Dimplex Guarantee there may be a charge to repair your product. However, we will contact you for agreement to any charges before any chargeable service is carried out.
What is not covered by a Dimplex Guarantee?
The Dimplex Guarantee does not cover any of the following:
Any fault or damage to your Dimplex product due to faulty materials or workmanship occurring outside the two year Guarantee Period.
Any fault or damage occurring to any pre-owned Dimplex product or to any other equipment or property.
Accidental damage to your Dimplex product or damage to your Dimplex product from external sources (for example, transit, weather, electrical outages or power surges).
Fault or damage to your Dimplex product which is:
Not due to faulty materials or workmanship or which is due to circumstances outside Dimplex’s control.
Caused by use of your Dimplex product for anything other than normal, dwelling usage in the country where it was purchased.
Caused by any misuse, abuse or negligent use of the Dimplex product, including but not limited to any failure to use it in accordance with the Operating Instructions supplied with the product.
Caused by any failure to assemble, install, clean and maintain your Dimplex product in accordance with the Installation Instructions supplied with the product unless this was carried out by Dimplex or its authorised dealers.
Caused by repairs or alterations to your Dimplex product not carried out by Dimplex service personnel or its authorised dealer(s).
- 28 -
Caused by use of any consumables or spare parts for your Dimplex product which are not Dimplex specified.
Terms and Conditions
The Dimplex Guarantee is valid for Dimplex from the date of purchase of your Dimplex product from a recognised retailer in the country of purchase and use, or the date of delivery of the product if later, always provided the original receipt has been retained and is produced as proof of purchase.
You must provide to Dimplex or its authorised agents on request the original receipt as proof of purchase and - if required by Dimplex - proof of delivery. If you are unable to provide this documentation, you will be required to pay for any repair work required.
Any repair work under the Dimplex Guarantee will be carried out by Dimplex or its authorised dealer(s) and any parts that are replaced will become the property of Dimplex. Any repairs performed under the Dimplex Guarantee will not extend the Guarantee Period.
Any replacement of your Dimplex product by Dimplex during the Guarantee Period will not start the Guarantee period afresh.
The Dimplex Guarantee does not entitle you to recovery of any indirect or consequential loss or damage including but not limited to loss or damage to any other property.
The Dimplex Guarantee is in addition to your statutory rights as a consumer and your statutory rights are not aected by this Dimplex Guarantee.
If you have any questions about what the Dimplex Guarantee covers and does not cover or how to claim under the Dimplex Guarantee, please contact us using the information on the back page.
Contact details
Millbrook House, Grange Drive, Hedge End, Southampton, SO30 2DF
Important
For electrical products sold within the European Community. At the end of the electrical products
useful life it should not be disposed of with household waste. Please recycle where facilities exist.
Check with a Local Authority or retailer for recycling advice in your country. Batteries should be
disposed of or recycled in accordance with WEEE Directive 2012/19/EU. Packaging should be
recycled where possible.
- 29 -
- 30 -
- 31 -
Customer Helpline: 0344 879 3588
aftersales@dimplex.co.uk
www.dimplex.co.uk
Glen Dimplex Heating & Ventilation
Millbrook House, Grange Drive, Hedge End, Southampton, SO30 2DF
© Glen Dimplex. All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex.
This product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014, EN60555-2 and EN60555-3. These cover the essential requirements of EEC Directives 2006/95/EC and 2004/108/EC
- 32 -
Loading...