Dimplex QM050, QM100, QM070, QM150, QM125 Installation Instructions

INSTALLATION MANUAL
Quantum Series Heater
Models: QM050 / QM070 / QM100
QM125 / QM150
- 1 -
300001917 ISSUE: 1 Series: Y
IMPORTANT
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE. Note also the information presented on the appliance
Warnings in this document are identifi ed by a warning triangle against a grey background. Keywords at the start of a warning indicate the type and seriousness of the ensuing risk if measures to prevent the risk are not taken.
The following keywords are defi ned and can be used in this document:
○ DANGER indicates a hazardous situation which, if not avoided, will result in
death or serious injury.
○ WARNING indicates a hazardous situation which, if not avoided, could result
in death or serious injury.
○ CAUTION indicates a hazardous situation which, if not avoided, could result in
minor to moderate injury.
○ NOTICE is used to address practices not related to personal injury.
CAUTION
FAILURE TO FOLLOW THESE INSTRUCTIONS MAY CAUSE INJURY AND/OR DAMAGE AND MAY INVALIDATE YOUR GUARANTEE
IMPORTANT SAFETY ADVICE
When using electrical heaters, basic precautions should always be followed to reduce the risk of fi re, electrical shock, and injury to persons, including the following:
IMPORTANT – The wall bracket supplied with the heater must be used. IMPORTANT – All packaging should be disposed of in an appropriate manner.
OVERHEATING WARNING
WARNING - In order to avoid overheating, do not cover or obstruct the heater. Do
not place material or garments on the heater, or obstruct the air circulation around the heater, for instance by curtains or furniture, as this could cause overheating and a fi re risk. NEVER cover or obstruct in any way the heat outlet slots at the top of the heater or the air outlet slots in the base of the heater.
WARNING - THE SURFACES ON THIS HEATER CAN BE HOT.
The heater carries a warning ‘DO NOT COVER’ to alert the user to the risk of fi re that exists if the heater is accidentally covered.
CAUTION - Some parts of this product can become very hot and cause burns.
Particular attention has to be given where children and vulnerable people are present.
For your safety this heater is fi tted with a thermal cut-out. In the event that the product overheats for some reason, the cut-out prevents excessive temperatures on the product by cutting the power to the heater. Once the heater has cooled down, it will reset automatically, it will continue to cycle on and o automatically until the reason for overheating is removed.
The display screen may fl ash red to indicate the product has overheated. To reset the display, remove the obstruction and hold Enter for 10 seconds.
- 2 -
SUITABLE APPLICATIONS
WARNING - This heater is suitable for normal dwelling purposes and should not be
used in any other type of environment. This product should only be used in the country where it was purchased from by a recognised commercial retailer. Do not use outdoors.
SERVICING AND REPAIRS
WARNING - Servicing and product repairs should only be undertaken by the
manufacturers approved service agent or a similarly trained or qualifi ed person, using only exact manufacturer approved spare parts. PLEASE NOTE: Household dust, lit cigarettes, candles and oil burners, combined with the convection e ect of electric heaters can cause signifi cant soot deposits to build up on the surface directly above and to the sides of the heater. This is not a fault of the heater. Extensive burning of candles or smoking in the operating environment of this product can produce heavy discolouration within a few months of use.
OPERATING WARNINGS
IMPORTANT: Remember to observe all safety warnings and precautions when
operating the heater on the automatic or timer modes, either attended or unattended since a fi re risk exists when the heater is accidentally covered, obstructed or displaced.
CAUTION: Do not use if either of the heater’s mains power leads become damaged. If
the supply cord is damaged it must be replaced by the installer or an approved Dimplex service partner.
Do not sit or stand on the heater. Ensure minimum clearances between the heater and other objects / surfaces are
maintained.
ELECTRICAL INSTALLATION
WARNING - Minimum clearances and IP zone requirements must be adhered to in
accordance with the current wiring regulations.
Mains cables are not provided with this heater.
WARNING - The electrical installation of this heater must be carried out by a suitably
qualifi ed or trained electrician, and be in strict accordance with current wiring regulations. The peak supply must be connected via a switched fused spur with a fuse rated suitably
for the appliances fl ex, the o -peak supply, via a 20A double pole isolated switch. In both instances a plug and socket arrangement MUST NOT be utilised. The contact separation to be a minimum of 3mm.
If the product is installed as a single supply (see page 17 for more details), a 20A DP switch must be used as the supply is covering peak and o peak loads.
Failure to follow these instructions will mean that the manufacturer’s instructions have not been adhered to. THERE ARE NO EXCEPTIONS.
• This heater must be earthed
• Not suitable for connection via a plug top
• Do not locate the heater immediately above, below or in front of a fi xed electrical point i.e. socket outlet.
This appliance is intended for installation to a single phase supply only and is not suitable for connection to 3 phase supplies.
- 3 -
ELECTRICAL INSTALLATION continued
The heater is not fi tted with a mains cable, this should be fi tted by the installer. Cable type (minimum size) H05VV-F 1.5mm three core for peak and 2.5mm three core for o -peak for connection to the fi xed wiring of the premises through suitable isolation devices positioned adjacent to the heater. The supply circuits to the heater must incorporate a double pole isolating switch having a contact separation of at least 3mm.
In installation the supply cord must be cut to the appropriate length for the electrical connection point. Excess cable should not be inserted or stored behind the heater.
If, during reassembly of the heater, a part of the thermal insulation shows damage or deterioration, it should be replaced by an identical part.
WARNING: All electrical connections to the terminal block must be secure to prevent
risk of ignition. Tighten to 2 Nm.
CHILD SAFETY
WARNING - Fixing kit screws are a potential choking hazard. WARNING - This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of appliance by a person responsible for their safety.
This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
Children of less than 3 years should be kept away unless continuously supervised.
Children aged from 3 years and less than 8 years shall only switch on/o the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children aged from 3 years and less than 8 years shall not regulate and clean the appliance or perform user maintenance.
WARNING - KEEP BATTERIES OUT OF REACH OF CHILDREN
WARNING - Packaging should be disposed of responsibly as the EPS used could
be a potential choking hazard for children.
- 4 -
This document is customer property and is to remain with this unit.
i
These instructions do not cover all the di erent variations of systems nor does it provide for every possible contingency to be met in connection with installation.
WARNING: EARTHING
This appliance must be earthed in accordance with the manufacturers recommendations and in accordance with IEE regulations for electrical equipment.
Failure to adequately earth the appliance can result in electrical shock causing severe personal injury or death.
WARNING: HAZARDOUS VOLTAGE
Disconnect all power to unit before installing or servicing.
Hazardous voltage can cause severe personal injury or death.
WARNING: ACCESS TO LIVE PARTS
If the supply cables to the appliance are damaged in anyway, they must be immediately replaced by a competent person in order to avoid electrocution which could cause severe personal injury or death.
WARNING
The appliance must be securely fi xed to the wall. The installed appliance could weigh up to 165kg and if it falls o the wall it could cause severe personal injury or death. It is the responsibility of the installer to ensure that the appropriate wall fi xing is used and that the fl oor is capable or bearing the full weight.
- 5 -
WARNING
To avoid a fi re hazard the cardboard insert within the heater core must be removed before the heater is switched on. Also ensure all polystyrene packaging is removed before the heater is operated. Leaving combustible packaging in the appliance could lead to fi re and cause severe personal injury, death and damage to property.
CAUTION
The appliance is very heavy (up to 50kg) and care should be taken when handling during installation to reduce risk of muscular or skeletal injuries.
CAUTION
The appliance should not be repeatedly switched on/o by an external room thermostat as this could lead to failures of the electronic controller and may invalidate the guarantee – further clarifi cation SHOULD BE SOUGHT FROM https://www.dimplex.co.uk/support.
i
CAUTION
During the fi rst 48 hours of operation rooms must be well ventilated as the heater will produce a smell. Young children, caged birds, or persons with respiratory complaints must not remain in close proximity to the appliance during the fi rst 48 hours or operation.
It is important that the appliance bricks are dry and free from mould growth. Wet or mouldy bricks can lead to an unpleasant odour and or steam being generated by the appliance which could upset the customer and damage the appliance
- 6 -
- 7 -
Energy Related Product Directive
Type of heat output / room temperature control
This product meets the Ecodesign requirements for an electric storage local space heater. Commission
Regulation (EU) 2015/1188.
Model Identifi er(s): QM050 QM070 QM100 QM125 QM150
Heat Output
Nominal heat output Pnom 0.50kW 0.75kW 1.00kW 1.25kW 1.50kW
Minimum heat output (indicative) Pmin
Maximum heat output Pmax,c 0.90kW 1.20kW 1.50kW 1.70kW 2.00kW
Auxiliary electricity consumption
At nominal heat output elmax 0.00 0.00 0.00 0.00
At minimum heat output elmin
In standby mode elSB
Type of Heat input, for electronic storage local space heaters only
Electronic heat charge control with room temperature feedback
Fan assisted heat output Yes
Type of heat output / room temperature control
0.00 0.00 0.00 0.00 0.00
0.00
0.00 0.00 0.00 0.00 0.00
0.000 0.000 0.000 0.000 0.000
Yes
Electronic room temperature control plus week timer
Contact details
Glen Dimplex Heating and Ventilation Millbrook House, Grange Drive, Hedge End, Southampton, SO30 2DF Tel: 0344 879 3588 This product meets the Ecodesign requirements for an electric storage local space heater. Commission Regulation (EU) 2015/1188.
Yes
Technical Details
Model Identifi er(s): QM050 QM070 QM100 QM125 QM150
Input rating +5% / -10% 936/1020W 1435/1560W
Boost Output 230/240V~ 312/340W 478/520W 681/740W 847/920W 1008/1100W
Rated Charge Period: 7.7 - 7 Hours 7.7 - 7 Hours 7.7 - 7 Hours 7.7 - 7 Hours 7.7 - 7 Hours
Max Storage Capacity 7.2kWh 10.9kWh 15.4kWh 19.3kWh 23.1kWh
2042/2220W
2540/2760W
3024/3300W
Fan Wattage 11W 11W 11W 11W 11W
UI Wattage 0.5W 0.5W 0.5W 0.5W 0.5W
Sound Level dB
(measured in test chamber)
Energy Cell Packs Required (047243) 4 6 8 10 12
Height (mm) 730 730 730 730 730
Width (mm) 580 703 865 1069 1069
Depth (mm) 185 185 185 185 185
27 29 32 30 31
- 8 -
All Models
Controls
Controller UI
Digitally controlled, Electronic Thermostat accurate to (±0.2°C).
Timer modes:
7 Day Programmable User Timer, Out All Day, Home All Day
Continuous heat modes:
Frost Protect
Additional Modes:
Away, Boost, Setback
Graphical display with RGB backlight
Tactile buttons with audio feedback
User replaceable battery (Coin-Type)
Open window detection, Adaptive Start, Advance Time Period
Wide SP range (7-30°C)
Automatic Charge Control
History / Reporting Screens
Boost Mode, User Adjustable
Heat Demand % Adjustment
Child Lock & Heater Lock (PIN-based)
Electronic overheat protection.
Safety
Additional electromechanical overheat protection. LVD and EMC compliance.
IP Rating IPX4
Battery
3.3V coin cell battery to backup real time clock. Battery life > 5 years.
Supply 1/N/1/N/PE ~230-240V (Peak + O Peak) 230-240V / 50Hz Class II
Colour / Finish
Tra  c White (RAL 9016), Grille RAL7035
Storage Core High-density bonded magnetite energy cells
Approvals UKCA, CE & BEAB
Guarantee 2 Years. 10 Years extended available with registration.
Country of Origin United Kingdom
Manufacturer
- 9 -
Glen Dimplex Heating & Ventilation (Glen Dimplex UK Ltd)
Preparation
Do not place objects within 300mm of the front of the heater and 150mm either side.
250 mm
150
mm
Fig. 1
150
mm
300 mm
‘W’
150mm 150mm
730mm
Models W (mm)
QM050 580
QM070 703
QM100 865
QM125 1069
QM150 1069
CAUTION
The appliance is very heavy (up to 50kg) and care should be taken when handling during installation to reduce risk of muscular or skeletal injuries.
- 10 -
NOTE:
Read these instructions carefully before proceeding any further with the installation
Fig. 2
CAUTION
Do not use the outer top panel or the rear heat shield to lift or carry the heater.
1. Place the heater fl at on the ground with arrows printed on the base of the carton pointing upwards.
Open the carton at the bottom, slide the heater out of the carton by at least 200mm exposing the feet
Fig. 3
and the fi xing kit located within the packaging on the right hand side. Remove the feet and the fi xing kit. (Fig. 2)
Y
X
Y
X
2. Secure the feet to the heater using all the screws provided (4 per heater). For models QM050, QM070 and QM100 two locations are possible indicated by X and Y markings visible on the base of the heater.
Ensure the feet are fi xed at the location holes marked with an ‘X’, (Fig. 3/3B).
However, if this is a replacement heater check the pitch of the feet and choose the appropriate fi xing positions - either X or Y.
Note - Foot screws are in the fi xing kit.
Fig. 3
X
Y
X
Y
- 11 -
Models
050
070
100
125 / 150
LH Foot RH Foot
XYXY
199 211 114 296 198 212 113 297
191 157 166 182 194 155 171 178
190 98 166 121 150 111 176 138
189 343 189 343 265 267 265 267
The Quantum feet can be fi tted in two di erent locations (X and Y). The X and Y are stamped onto the base of the heater indicating the 2 locations
Fig. 3b
Y
3. Remove the centre EPS piece and stand the heater on its feet before removing the packaging.
Dispose of the packaging in an appropriate way.
X
YX
WARNING
To avoid a fi re hazard the cardboard insert within the heater core must be removed before the heater is switched on. Also ensure all polystyrene packaging is removed before the heater is operated. Leaving combustible packaging in the appliance could lead to fi re and cause severe personal injury, death and damage to property.
- 12 -