Dimplex PX01001 Installation And Operating Instructions Manual

2. The location of the control is important, it will not function correctly if above or within 500mm of a heat source or draught. Care must also be taken not to obscure the slots at the top or bottom of the control and that it is not exposed to direct bright sunlight or close to a lamp fitting. Best temperature accuracy will be achieved by mounting on an internal wall or partition.
Vertical tabs in metal pattress boxes should be removed. Ensure all entries into the pattress boxes are sealed to prevent draughts.
4. Before fitting to the mounting box setback temperature,
comfort temperature and comfort period must be selected. To do this, adjust the appropriate dial on the reverse of the PCB.
5. The supply cable is not provided and should therefore be selected to suit the appliance.
Warning: Although the control does not need an earth, the
appliance probably does. Ensure that the mounting box is fitted with an earth terminal for earth continuity to the appliance.
6. To connect the control in circuit wire in to the clearly marked terminal block on the rear of the controller. The control must only be connected via fixed wiring.
7. Secure the control to the pattress box such that there are no
gaps between the controller and wall or pattress box.
Note: If tamperproof screws are required they should be M3 x 40mm long, counter sunk with a head diameter of no more than 6.5mm.
Installation and Operating Instructions
Press Button Delay Timer - Model No. PX01001
Safety Warnings
1. WARNING: DO NOT USE THIS APPLIANCE IN THE IMMEDIATE SURROUNDINGS OF A BATH, A SHOWER OR SWIMMING POOL
2. WARNING: DO NOT USE WHERE EXCESSIVE DUST OR MOISTURE IS PRESENT
3. WARNING: FOR USE IN NORMAL POLLUTION SITUATIONS ONLY
General Description
The PX01001 timer/thermostat can be used in conjunction with heating appliances. They may be flush or surface mounted using a standard 25mm box. The control is rated at 16A (250VAC) and can be used in conjunction with heating appliances wit h a m ax i m um t ot a l input of 13 A resistive L.C. 230V - 50Hz. The controller cannot be used with a Quartz heater without a suitable i n-line contactor. Control action: Type 1B
Operating Instructions
The PX01001 controls the room temperature by interrupting the power supply to the appliance, therefore the appliance should always be switched on and its thermostat set to maximum temperature. Note this will not be reached if the pre-determined maximum level is below that of the appliance thermostat setting.
When the comfort mode is activated by pressing the
centre of the control face, the green light illuminates. The comfort mode allows the room to be heated to a pre­ determined temperature for a pre-determined time period.
The red light indicates that the heater is operating. Note that the heater will remain on for a minimum of 1
minute.
The red light may also b e i l l uminated in the set back mode when the PX01001 switches the heater on to maintain the predetermined background temperature.
Installation
Before undertaking installation work, ensure the electricity supply is disconnected from any relevant fixed wiring.
1. The control and heater should be installed in compliance with the IEE Wiring Regulations
comfort control
Dimplex
TOUCH
85mm
85mm
25mm
boost
Main Dimensions
boost
Ensure 500mm clearance from any heat source or draught.
T0105/004/A
General Cleaning
WARNING BEFORE UNDERTAKING CLEANING WORK ON THE CONTROLLER OR APPLIANCE IMMEDIATELY DISCONNECT THE ELECTRICITY SUPPLY BY SWITCHING OFF AT THE ADJACENT DOUBLE POLE SWITCH.
The outside of the appliance should be wiped over with a soft damp cloth and then dried. Do not use detergents or abrasives.
After Sales Service
Your Dimplex Comfort Control is guaranteed for one year from date of purchase. We undertake to exchange or repair free of charge within this period, any part found to be defective.
Should you require after sales service, please get in touch with the supplier through whom you purchased the appliance , or your nearest Service Agent.
Please do not initially return a faulty appliance or part of an appliance to us as this may result in transit damage and/or delay in providing service. Let us know your difficulty quoting the model number and series of the appliance. We will then take the appropriate action.
L
Live
Output Live Neu-
N
Setback temp.
Comfort temp.
Timing
16ºC 25ºC 5ºC 19ºC
Comfort Temperature Setback Temperature
Glen Dimplex UK Ltd Millbrook House Grange Drive Hedge End
Southampton Hampshire SO30 2DF
Customer Services: Tel. 0870 7270101 Fax. 0870 7270102 email customer.services@glendimplex
Republic of Ireland Tel. 01 8424833
HEATER
OUT
IN
IN OUT
L
N
Control SWITCHED
FUSED
SPUR
Minimum 500mm
230VAC MAINS
FROM FUSED or
BREAKERED
SOURCE
Ensure the heater is properly earthed with the Fused Spur
Wiring Diagram
HEATER
OUT
IN
IN OUT
L
N
Control SWITCHED
FUSED
SPUR
Minimum 500mm
230VAC MAINS
FROM FUSED or
BREAKERED
SOURCE
Ensure the heater is properly earthed with the Fused Spur
Alternative
0
240
Timing (Mins)
Installation contd..