These instructions should be read carefully
and retained for future use. Note also the
information presented on the appliance.
08/80261/0 ISSUE: 3 Series: A
IMPORTANT
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR
FUTURE REFERENCE. Note also the information presented on the appliance
CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS MAY CAUSE INJURY AND/
OR DAMAGE AND MAY INVALIDATE YOUR GUARANTEE
IMPORTANT SAFETY ADVICE
When using electrical heaters, basic precautions should always be followed to reduce
the risk of fire, electrical shock, and injury to persons, including the following:
IMPORTANT: The wall bracket supplied with the heater must be used.
IMPORTANT: All packaging should be disposed of in an appropriate manner.
OVERHEATING WARNING
WARNING: In order to avoid overheating, do not cover or obstruct the heater. Do not
place material or garments on the heater, or obstruct the air circulation around the heater,
for instance by curtains or furniture, as this could cause overheating and a fire risk. NEVER
cover or obstruct in any way the heat outlet slots at the top of the heater or the air inlet
slots in the base of the heater.
WARNING:
THE SURFACES ON THIS HEATER CAN BE HOT. The heater carries a
warning ‘DO NOT COVER’ to alert the user to the risk of fire that exists if the heater is
accidentally covered. DO NOT place combustible items through the heater grille.
CAUTION: Some parts of this product can become very hot and cause burns. Particular
attention has to be given where children and vulnerable people are present.
For your safety this heater is fitted with a thermal cut-out. In the event that the
product overheats for some reason, the cut-out prevents excessive temperatures on
the product by cutting the power to the heater. Once the heater has cooled down,
it will reset automatically, it will continue to cycle on and o automatically until the
reason for overheating is removed. The display screen may flash red to indicate the
product has overheated. To reset the display, remove the obstruction and hold Enter
for 10 seconds.
2
SUITABLE APPLICATIONS
WARNING: This heater is suitable for normal domestic household purposes and
should not be used in any other type of environment. This product should only be
used in the country where it was purchased from by a recognised commercial retailer.
Do not use outdoors.
SERVICING AND REPAIRS
:
WARNING
Servicing and product repairs should only be undertaken by the
manufacturers approved service agent or a similarly trained or qualified person, using
only exact manufacturer approved spare parts.
PLEASE NOTE: Household dust, lit cigarettes, candles and oil burners, combined with
the convection eect of electric heaters can cause significant soot deposits to build
up on the surface directly above and to the sides of the heater. This is not a fault of the
heater. Extensive burning of candles or smoking in the operating environment of this
product can produce heavy discolouration within a few months of use.
OPERATING WARNINGS
IMPORTANT: Remember to observe all safety warnings and precautions when
operating the heater on the automatic or timer modes, either attended or unattended
since a fire risk exists when the heater is accidentally covered or displaced.
CAUTION: Do not use if the heater’s mains power lead is damaged. If the supply cord
is damaged it must be replaced by the installer or an approved Dimplex service partner.
3
ELECTRICAL INSTALLATION
WARNING: The electrical installation of this heater must be carried out by a
suitably qualified or trained electrician, and be in strict accordance with the
current wiring Regulations BS 7671. The supply must be connected via a switched
fused spur with a fuse rated suitably for the appliances flex. Failure to follow these
instructions will mean that the manufacturer’s instructions have not been adhered to.
THERE ARE NO EXCEPTIONS.
WARNING: Minimum clearances and IP zone requirements must be adhered to in
accordance with the current wiring regulations.
The wires in this mains lead are coloured in accordance with the following code:
GREEN AND YELLOW: EARTH
BLUE: NEUTRAL
BROWN: LIVE
• This heater must be earthed
• Not suitable for connection via a plug top
• Do not locate the heater immediately below a fixed electrical point i.e. socket outlet.
The heater is fitted with a length of flexible cable type H05VV-F size 3 x 1.0mm² for 500W
to 2kW models for connection to the fixed wiring of the premises through a suitable
connection box positioned adjacent to the heater. A means for disconnection must be
incorporated in the fixed wiring of the premises in accordance with the current wiring
regulations. The supply circuit to the heater must incorporate a double pole isolating
switch having a contact separation of at least 3mm. Products that are supplied without
a plug are for installation into the fixed wiring of the property, via a suitable double pole
switched fused spur with a fuse rated suitably for the appliances flex. Typical fuse ratings
for 230V equipment - Up to 700W = 3A, over 700W = 13A.
In installation the supply cord must be cut to the appropriate length for the electrical
connection point. Excess cable should not be inserted and stored behind the heater.
WARNING: This heater must not be connected to the electricity supply via an external
switching device (such as a timer) or a circuit that is regularly switched on and o by
the utility supplier. Failure to follow this warning could result in the heater’s thermal
cut-o being inadvertently reset and could create a fire hazard. Cables/flexes that are
supplied pre-fitted to the product must NOT be extended.
4
CHILD SAFETY
WARNING: This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of appliance by a
person responsible for their safety.
This appliance can be used by children from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they
have been given supervision or instruction concerning use of the appliance. Children
shall not play with the appliance. Cleaning and user maintenance shall not be made by
children without supervision. Children of less than 3 years should be kept away unless
continuously supervised.
Children aged from 3 years and less than 8 years shall only switch on/o the appliance
provided that it has been placed or installed in its intended normal operating position
and they have been given supervision or instruction concerning use of the appliance in
a safe way and understand the hazards involved. Children aged from 3 years and less
than 8 years shall not regulate and clean the appliance or perform user maintenance.
This product contains a replaceable battery.
WARNING: KEEP BATTERIES OUT OF REACH OF CHILDREN.
WARNING: Packaging should be disposed o responsibly as the EPS could be a
potential choking hazard for children
5
Energy Related Product Directive
This product complies with Lot20 of the Energy Eciency Directive (2015/1188).
Type of heat output/ room temperature control
With electronic room temperature controlYes
Electronic room temperature control plus week timerYes
ManufacturerGlen Dimplex Heating & Ventilation (GDC Group Ltd.)
7
General Information
Please read the instructions closely before first using the product, there is also a
quick-start guide on page 8 if you need a reminder of how to use the basic functions
in the future. The heater is designed for wall mounting using the wall bracket supplied.
It should only be operated when in the upright position as shown - see Fig.3 and Fig.4.
All models are splash proof to IP24. Before connecting the heater check that the supply
voltage is the same as that stated on the heater.
WARNING:
This product is heavy and care
should be taken in installation
Wall Mounting Instructions
IMPORTANT - The wall bracket
supplied with the heater must
be used and the heater must
be installed in the correct
orientation. The fixings should
be used to secure the bracket to
the particular wall on which the
heater will be installed. The heater
should be positioned observing
the minimum clearances stated
around the heater - see Fig. 2,
Fig. 3 and Fig. 4.
‘B’
Minimum
mounting
clearance
MODELABCDE
MFP050E
MFP075E
MFP100E
MFP150E
MFP200E
‘A’
390mm 150mm 503mm 536mm104mm
390mm 150mm 503mm 536mm104mm
560mm 150mm671mm 536mm104mm
630mm 150mm741mm 536mm104mm
800mm 150mm911mm536mm104mm
Fig. 2
300mm
255mm
Minimum mounting clearance
8
To mount the heater to the wall:
1. Remove wall mounting bracket from the back of the heater by depressing the spring
latch at the side of each bracket - see Fig.2.
2. Fix the wall bracket securely to the wall through the four screw holes. Ensure only
screw fittings suitable for the particular wall type are used.
3. Present the heater to the wall bracket and engage bottom slots in the back with
bracket hooks.
4. Press the top of the heater into locked position and ensure the clips on the top are
engaged.
150mm
(min)
‘D’
Minimum mounting clearance
‘C’
150mm
(min)
Fig. 3
mm
150
(min)
Shelf / Obstruction
300mm
(min)
Minimum front
clearance
300mm
150mm
Fig. 4
‘E’
(min)
*Please note correct product
orientation is with controller
facing top right side only
9
Loading...
+ 19 hidden pages