IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Important Safety Advic When using ele
followed to reduce the risk of fire, ele including the fol
If the appliance is damaged, check with the suppl
n.
operatio Do not use o Do not us
pool. Do not locate the heater immediately below a fixed socket outlet or
connection box. This appl
sistance or supervision if their physical, sensory or mental capabilities
as pre
vent them from using it safely. Children should be supervised to ensure
that they do not play Do not use this heater in serie
a timer or any other de fire risk exists when the heater
Ensure that furniture, curtains or other comb no closer than 1 metre from the he
In the event of a fault unplug the heater. Un
plug the heater when not required for long periods.
Although this heater compl its use o
The ap If the supply cord is damaged it must be replaced by the manufacturer or
service agent or a similarly qual Keep the sup
utdoors.
e in the immediate surroundings of a bath, shower or swimming
iance is not intended for use by children or other persons without
n deep pile carpets or on long hair type of rugs.
pliance must be positioned so that the plug is accessible.
ply cord away from the front of the heater.
WA
RNING: In order to avoid overheating, do not cover the heater. Do not plac circulation around the he in
dicating that it must not be covered.
e:
ctrical appliances, basic precautions should always be
lowing:
with the appliance.
e material or garments on the heater, or obstruct the air
s with a thermal control, a program controller,
vice that switches on the heat automatically, since a
ies with safety standards, we do not recommend
ctrical shock and injury to persons,
ier before installation and
is accidentally covered or displaced.
ater.
ified person in order to avoid a hazard.
ater. The heater carries the Warning symbol
ustible material are positioned
Cleaning
WARNING – ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE CLEA
NING THE HEATER.
For gen
eral cleaning use a soft clean duster – never use abrasive cleaners. The glass
g screen should be cleaned carefully with a soft cloth. DO NOT use proprietary
viewin glass cleaners. To remove a clea
ny accumulation of dust or fluff the soft brush attachment of a vacuum
ner should occasionally be used to clean the outlet grille of the fan heater.
Recycling
For electrical products sold within the European Community.
At the e
nd of the electrical products useful life it should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retai
ler for recycling advice in your country.
After Sales Service
Should you require after sales service or should you need to purchase any spares,
ase contact the retailer from whom the appliance was purchased or contact the
ple service n
umber relevant to your country on the warranty card. Please do not return a faulty product to us in th in providing you with a satisfactory service. Please retain your receipt as proof of purchase.
e first instance as this may result in loss or damage and delay
General
Unpack the heater carefully and retain the packaging for possible future use, in the event of
moving or returning the fire to your supplier.
Th
e fire incorporates a flame effect, which can be used with or without heating, so that the comforting ef its own only requires l
Th
ese models are designed to be free standing and are normally positioned against a
l.
wal Before con
the heater.
on
Please note: Used in an enviro be p
ossible to hear a sound which is related to the operation of the flame effect.
is normal and should not be a cause for concern.
This
fect may be enjoyed at any time of the year. Using the flame effect on
ittle electricity.
necting the heater check that the supply voltage is the same as that stated
nment where background noise is very low, it may
Electrical connection
WARNING – THIS APPLIANCE MUST BE EARTHED
This heater must be used on an AC ~ supply only and the voltage marked on the heater must correspond Before switching on, please re
Wall fixing
Dri
ll holes using a 6mm drill as illustrated. Insert plugs and screws. The raw plug
ied is suitable for use in block walls (special fasteners required on stud walls). Do
suppl not ful
ly tighten screws, leave the head of the screw at least 10mm away from the wall.
the keyhole slots on the fire over the screws and lower into position.
Place
Controls
Three switches provide a choice of heat the side with
Switch 1 (I) Controls the ele
Switch 2 (I) Provides 1kW he Switch 3 (I
- see Fig. 2
the markings on (i.e. I, I, or II) is pushed in.
I) Provides 2kW output with switch 2
to the supply voltage.
ad the safety warnings and operating instructions.
- see Fig. 1
Note: This sw operate with or with
itch must be in the ON (I) position for heater to
settings. A switch is in the ON position when
ctricity supply to the heater and flame effect.
out heat.
at output
UK
Thermostat (T)
In ord
er to maintain a certain room temperature, set the controller to ‘max.’. Operate
the appl
iance at full power until the required room temperature is reached. Set back
the
thermostatic controller until the appliance switches off with an audible “click”. This temperature wi off automatical thermostat
setting is higher than the room temperature.
- see Fig. 2
ll be kept almost constant by the thermostatic control switching on and ly. Please note that the appliance can only be switched on when the
Thermal Safety Cut-out
A thermal safety cut-out is incorporated in the heater to prevent damage due to overhe
ating. This can happen if the heat outlet was restricted in any way. The heater
wi
ll switch on once the obstruction has been removed and the heater has cooled. If the cut-out continues to operate intermittently, the heater should be switche service a
gent contacted.
Lamp Replacement
To g
ain access to the lamps remove the fuel effect from the fire by removing the fixing
screws from Remove the rotisserie by careful (Fig. 4). Remove Replace with a 60W E14 S lamp. Refit
the fuel bed and sliding out the fuel effect (Fig. 3).
the defective lamp by unscrewing it as shown in Fig. 5.
fuel effect and secure it with the screws.
- see Fig. 3, Fig. 4 and Fig. 5
ly sliding the rubber connecter off the motor shaft
ES Clear Candle lamp. Take care not to over-tighten the