F567486
Operating Instructions
Air-to-Water Heatpump
Model No.
Indoor Unit
Outdoor Unit
LIAC12IM6 LIAV12IM
LIAC14IM6 LIAV14IM
LIAC16IM6 LIAV16IM
ENGLISH
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Before operating the unit, make sure the installation has been carried out correctly by authorized dealer correctly and
precisely following the installation instructions given.
FRANÇAIS
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure.
Avant de faire fonctionner l’unité, assurez-vous que l’installation a été correctement réalisée par un revendeur agréé
et dans le strict respect des consignes d’installation fournies.
10 ~ 17
ESPAÑOL
Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como
futuro elemento de consulta.
Antes de operar la unidad asegúrese de que la instalación haya sido realizada correctamente por un distribuidor
autorizado, siguiendo de forma correcta y precisa las instrucciones de instalación dadas.
18 ~ 25
DEUTSCH
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie
sie für die künftige Verwendung auf.
Vor der Inbetriebnahme dieses Geräts ist sicherzustellen, dass die Montage durch einen autorisierten Händler
fachgerecht entsprechend der Installationsanleitung durchgeführt wurde.
26 ~ 33
0.2
0.40
0.30.1
MPa
TIMER OUTDOOR
HEAT
SETTING
STATUS
PUMPDW
BOOSTER
QUIET
TANK
WATER OUTLET
C
C
OFF
/
ON
HEATER
OPERATION
FORCE
HEATER
ACTUAL
TIMER
1
MONTUEWEDTHUFRI SAT SUN
SOLAR REMOTE
NOT AVAILABLE
23 4 56
ON
OFF

2
• This manual describes how to operate the Heatpump system
between indoor and outdoor units only.
•
Other operation such as water tank, radiator, external thermo controller
and underfl oor system, please refer to respective manufacturer
operation manuals.
SAFETY PRECAUTIONS
TABLE OF CONTENTS
SAFETY PRECAUTIONS
2~3
CONTROL PANEL
4~7
INDOOR UNIT
8
TROUBLESHOOTING
9
INFORMATION
34~35
NOTE
The illustrations in this manual are for
explanation purposes only and may
differ from the actual unit. It is subjected
to change without notice for future
improvement.
OPERATION CONDITION
Water outlet
Temperature (°C)
Indoor
HEATING
Max. 55
Min. 25
Ambient
Temperature (°C)
Outdoor
HEATING
Max. 35
Min. -20
NOTICE :
When the outdoor temperature
is out of the above temperature
range, the heating capacity will
drop signifi cantly and outdoor
unit might stop for protection
control.
To prevent personal injury, injury to others, or property damage, please
comply with the following.
Incorrect operation due to failure to follow instructions below may cause
harm or damage, the seriousness of which is classifi ed as below:
WARNING
This sign warns of death or serious injury.
CAUTION
This sign warns of injury or damage to
property.
The instructions to be followed are classifi ed by the following symbols:
This symbol denotes an action that is
PROHIBITED.
These symbols denote an actions that
is COMPULSORY.
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
Please consult authorized dealer or specialist to repair,
install, remove and reinstall the unit. Improper installation
and handling will cause leakage, electric shock or fi re.
Do not install the unit in a potentially explosive or fl ammable
atmosphere. Failure to do so could result in fi re.
Do not insert your fi ngers or other objects into the
air conditioner indoor or outdoor unit, rotating parts
may cause injury.
Do not touch the outdoor unit during lightning, it may cause
electric shock.
Do not attempt to repair the unit by yourself. Otherwise,
it may cause injury if it is mishandling.
Do not install the indoor unit at outdoor. This is designed for
indoor installation only.

Floor Heating
Panel
Control Panel
Power Supply
Water Tank Unit
Indoor Unit
Outdoor Unit
CAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water,
benzene, thinner or scouring powder.
Do not install the unit close to any combustible
equipment or at bathroom. Otherwise, it may
cause electric shock or fi re.
Do not touch the water discharge pipe at the
indoor unit during operation.
Do not place anything on top or beneath of the
unit.
Do not sit or step on the unit, you
may fall down accidentally.
Do not touch the sharp aluminium fi n,
sharp parts may cause injury.
Ensure drainage pipe is connected properly.
Otherwise, leakage may occur.
Check the installation rack periodically to make
sure that it is not damaged. After long periods
of use, the strength of the installation rack may
have deteriorated.
CONTROL PANEL
Do not let the control panel get wet. Otherwise,
it may cause electric shock or fi re.
Do not press the buttons on the control panel
with hard, pointed objects. Otherwise, it may
damage the unit.
Do not wash the control panel with water,
benzene, thinner or scouring powder.
Do
not inspect or service the control panel by
not inspect or service the control panel by
yourself. Please consult authorized dealer.
yourself. Please consult authorized dealer.
Otherwise, it may cause injury if mishandling.
WARNING
POWER SUPPLY
Do not use modifi ed cord,
joint cord, extension cord or
unspecifi ed cord to prevent
overheating and fi re.
Do not share the same power outlet with other
equipment to prevent overheating and fi re.
Do not operate with wet hands to prevent electric
shock.
If the supply cord is damage, it must be replaced
by the manufacturer, its service agent or similarly
qualifi ed persons in order to avoid a hazard.
This unit is equipped with Residue Current
Circuit Breaker (RCCB). It is strongly
recommended to check the operation of the
RCCB after installation and periodically after
servicing or maintenance by authorized dealer
to ensure it is in good working order. Otherwise,
it may cause electrical shock or fi re in case of
malfunction.
It is recommended to wear gloves during
servicing or maintenance in order to avoid
hazard.
This equipment must be earthed to prevent
electrical shock or fi re.
In case of emergency or abnormal conditions
(burnt smell, etc), turn off the power supply, and
please consult authorized dealer.
Prevent electric shock by switching off the power
supply when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity.
This appliance is for multiple uses. All power
supply circuits must be turn off before access to
any of the terminals in the indoor unit, to avoid
electrical shock, burn or fatal injury.

4
CONTROL PANEL
TIMER OUTDOOR
HEAT
SETTING
STATUS
PUMPDW
BOOSTER
QUIET
TANK
WATER OUTLET
C
C
SET
SELECT
CANCEL
ERROR
RESET
SETTING
STATUS
SEARCH
PUMPDWFORCECLOCK
CHECK
OFF
/
ON
MODE
HEATER
QUIET
OFF/ON
TIMER
HEATER
OPERATION
FORCE
HEATER
ACTUAL
TIMER
1
MON TUEWEDTHU FRI SAT SUN
REMOTE
2 3 4 56
ON
OFF
• Some functions described in this manual may not be applicable to your unit.
• Consult your nearest authorized dealer for further information.
• For normal operation, the
ERROR
RESET
,
FORCE
and
PUMPDW
buttons are not in use.
1
OFF/ON Button
14
Quiet Operation OFF/ON Indicator
2
Operation LED
15
Backup Heater Request OFF/ON Indicator
3
Operation Mode Button
16
Force Heater Request OFF/ON Indicator
4
Quiet Operation Button
17
Backup Heater Actual Operation (OFF/ON) Indicator
5
Indoor Unit Backup Heater Operation Button
18
Booster Heater Actual Operation (OFF/ON) Indicator
6
System Setting Mode Buttons
19
System Setting Mode OFF/ON Indicator
7
Timer Setting Group Buttons
20
System Status Check Mode OFF/ON Indicator
8
Force Heater Mode Button
21
System Pumpdown Mode OFF/ON Indicator
9
System Pumpdown Mode Button
22
Timer/Clock Setting Display
10
System Status Check Mode Buttons
23
Remote Display
11
Error Reset Button
24
Outdoor Ambient Temperature Display
12
Heat Mode OFF/ON Indicator
25
Water Outlet Temperature Display
13
Tank Mode OFF/ON Indicator
Notes:
• The current day and time need to be set when:
- The power is turned on for the fi rst time.
- After a long time has elapsed since the power was last
turned on.
• The current time that has been set will be the standard
time for all the Timer operations.
1. Press
CLOCK
.
2. Press
or to set current day.
3. Press
SET
to confi rm.
4. Repeat steps 2 and 3 to set the current time.
CONTROL PANEL PREPARATION
Setting Current Day and Time
16
1
22
21
10
17
18
19
20
24
9
5
25
3
8
4
7
2
15
14
12
13
6 11
23

SETTING UP THE SPECIAL FUNCTIONS
SETTING UP THE SPECIAL FUNCTIONS
• After initial installation, you can manually adjust the settings. The initial setting remains active until the user changes it.
• The control panel can be used for multiple installations. Some functions may not be applicable to your unit.
TIMER OUTDOOR
HEAT
SETTING
STATUS
PUMPDW
BOOSTER
QUIET
TANK
WATER OUTLET
C
C
HEATER
OPERATION
FORCE
HEATER
ACTUAL
MON TUE WEDTHU FRI SAT SUN
REMOTE
ON
Day display
YES / NO / Temperature display
SETTING / STATUS indicatorFunctions*Timer display
SET
SELECT
CANCEL
SETTING
STATUS
SEARCH
CHECK
SELECT FUNCTIONS AND SET YOUR DESIRED TIMER
1. Press
SET
and
CHECK
simultaneously for 5 seconds to enter special setting mode. “SETTING” and “STATUS” indicator is ON.
2. Press
or to browse functions.
3. Press
SELECT
to enter the function.
4. Press
or to enable YES or disable NO function, or set your desired day and time.
5. Press
SET
to confi rm.
Display Function *
External Thermo Controller (YES / NO)
To set external thermo controller connection.
Tank Connection (YES / NO)
To set tank connection.
Heating Priority (YES / NO)
To choose the heat pump only use for Heating side during HEAT + TANK mode.
Heating Heat-up Interval Set
To set timer for Heating during HEAT + TANK mode (0.5hour ~ 10hours).
Tank Heat-up Interval Set
To set timer for Tank during HEAT + TANK mode (5minutes ~ 1hour 35minutes).
Booster Heater Delay Time Set
To set delay timer for booster heater to ON if tank temperature is not reached (20minutes ~ 1hour 35minutes).
Sterilization (YES / NO)
To set sterilization, if required.
Sterilization Day & Time Set
To set timer for sterilization (only once a week).
Sterilization Temperature Set
To set temperature for sterilization function (40°C ~ 75°C).
Sterilization Continue Time
To set timer to maintain heating temperature in order to complete the sterilization function (5minutes ~ 1hour).

6
BASIC OPERATION
OFF
/
ON
TO TURN ON OR OFF THE UNIT
• When unit is ON, operation LED is lit and the actual
temperature for water outlet and outdoor ambient are
shown on the control panel display.
MODE
TO SELECT OPERATION MODE
HEAT HEAT +TANK TANK
• HEAT MODE
- To turn ON or OFF the panel/fl oor heating operation.
- In this mode, the outdoor unit will provide heating
capacity to the indoor unit.
• HEAT + TANK MODE
- In this mode, the outdoor unit will provide heating
capacity to the sanitary tank and indoor unit.
- This operation is not used when the sanitary water
tank is not installed.
• TANK MODE
- To turn ON or OFF the sanitary tank operation.
- In this mode, the outdoor unit will provide heating
capacity to the sanitary tank.
QUIET
TO ENJOY QUIET ENVIRONMENT
• This operation reduces outdoor unit noise. In this
condition, it may cause decrease in heating capacity.
HEATER
BACKUP HEATER OPERATION
• The backup heater provides extra heating capacity
during cold outdoor temperature and only can operated
at heat mode operation for indoor unit.
• The backup heater will automatically turn ON when the
setting conditions is fulfi lled.
• To cancel the Heater operation manually, press the
respective button again.
STATUS
SEARCH
CHECK
SYSTEM STATUS CHECK MODE
1. Press
CHECK
for 5 seconds to enter STATUS mode.
2. Press or to check the Compressor
Running Frequency or Error History.
• Press
to exit STATUS mode.
• Once STATUS mode is entered, “STATUS”
indicator is ON.
• STATUS mode cannot be activated when the
“SETTING” indicator is ON.
• It is strongly recommended to contact the nearest
authorized dealer to change the water temperature
range.
• Using the control panel could set the temperature
range for water outlet temperature and outdoor ambient
temperature.
SYSTEM SETTING MODE
TIMER OUTDOOR
HEAT
SETTING
STATUS
PUMPDW
BOOSTER
QUIET
TANK
WATER OUTLET
C
HEATER
OPERATION
FORCE
HEATER
ACTUAL
ON
Operation Mode Temperature display
SETTING indicator
Parameter *
1. Press
SET
for 5 seconds to enter “SETTING” mode.
“SETTING” indicator is ON.
2. Press
or to choose a parameter.
3. After selecting the desired parameter, press
SELECT
to
enter the parameter.
4. Press
or to set the desired temperature.
5. Press
SET
again to confi rm the setting.
• Repeat steps 2 to 5 to set other parameters.
Mode Parameter *
HEAT Outdoor ambient set temperature at low
water outlet temperature (-15°C ~ 15°C).
HEAT Outdoor ambient set temperature at high
water outlet temperature (-15°C ~ 15°C).
HEAT Water outlet set temperature at low outdoor
ambient temperature (25°C ~ 55°C).
HEAT Water outlet set temperature at high outdoor
ambient temperature (25°C ~ 55°C).
HEAT Set temperature for turning OFF heating
operation (5°C ~ 35°C).
HEATER Outdoor ambient set temperature for turning
ON heater operation (-15°C ~ 20°C).
TANK Sanitary tank set temperature
(40°C ~ 75°C).
WATER TEMPERATURE THERMO SHIFT SETTING
Ensure the operation LED is in OFF condition before setting.
1. Press
SET
within 5 seconds.
• Repeat steps 3 to 5 to set the desired shift temperature
(-5°C ~ 5°C).
Notes:
• Press
or wait 30 seconds to exit “SETTING” mode.
• The setting temperature will be stored in the system
once confi rm.
• “SETTING” mode cannot be activated when the
“PUMPDW” and “STATUS” indicator is ON.
ADVANCE OPERATION

ENGLISH
7
Timer Display
TIMER
1
MON TUEWEDTHU FRI SAT SUN
2 3 4 5 6
ON
OFF
Lights up if Timer
operation is selected
Day to be selected
ON Timer
To automatically switch “ON” the unit
6 different programs can be set in a day (1 ~ 6)
Indicates the selected day
Indicates the next timer operation day
Time to be selected (10 minutes step)
OFF Timer
To automatically switch “OFF” the unit
SET
SELECT
CANCEL
SETTING
CLOCK
OFF/ON
TIMER
Function Step
Enter timer mode
Press
TIMER
.
Set day & time
1.
Press or to select your desired day.
2. Press
SELECT
to confi rm
3. “1” will be blinking, press
SELECT
to set program 1.
4. Press
OFF/ON
to select ON or OFF timer.
5. Press or to select your desired time.
If you want to set the timer together with other operations, press
MODE
and
QUIET
.
6. Press
SET
to confi rm program 1. The selected day will be highlighted with ▼.
• After 2 seconds, the display will move to the next program.
7. Repeat steps 4 to 7 to set programs 2 to 6.
• During timer setup, if no button is pressed within 30 seconds, or if the
SET
button is pressed the
setting at that moment is confi rmed and timer setup is ended.
Add/Modify timer
Repeat the steps above.
Disable timer
Press
TIMER
, then press
CANCEL
.
Enable timer
Press
TIMER
, then press
SET
.
Check timer
1. Press
TIMER
.
2. Press or until your desired day is shown, press
SELECT
to confi rm your selection.
3. Press or to check the set programs.
Cancel timer
1. Press
TIMER
.
2. Press or until your desired day is shown.
3. Press
SELECT
to enter program setting.
4. Press
or until your desired program is shown.
5. Press
CANCEL
to cancel the program.
WEEKLY TIMER SETTING
Notes:
• You can set the Timer for each day of the week (Monday to Sunday) with 6 programs per day.
• ON Timer can be set together with your desired temperature and this temperature will be used continuously.
• Same timer program cannot be set in the same day.
• You may also select collective days with same timer setting.
• Promotes energy saving by allowing you to set up to 6 programs in any given day.

0.2
0.40
0.30.1
MPa
TIMER OUTDOOR
HEAT
SETTING
STATUS
PUMPDW
BOOSTER
QUIET
TANK
WATER OUTLET
C
C
OFF
/
ON
HEATER
OPERATION
FORCE
HEATER
ACTUAL
TIMER
1
MONTUEWEDTHUFRI SAT SUN
SOLAR REMOTE
NOT AVAILABLE
23 4 56
ON
OFF
8
INDOOR UNIT
CAUTION
• Switch off the power supply before cleaning.
WATER PRESSURE GAUGE
0.2
0.40
0.30.1
MPa
• Do not press or hit the glass
cover with hard, pointed
objects. This may damage the
unit.
• Ensure that the water
pressure is between 0.05 to
0.2MPa.
• In case the water pressure is
out of the above range, please
consult authorized dealer.
HINT
• Do not use benzene, thinner or scouring powder.
• Use only soap (
pH7) or neutral household detergent.
• Do not use water hotter than 40°C.
• To ensure optimal performance of the unit, cleaning
maintenance has to be carried out at regular intervals.
Please consult authorized dealer.
INDOOR UNIT & CONTROL PANEL
• Do not splash water directly.
• Wipe the unit gently with a soft, dry cloth.
OUTDOOR UNIT
• Do not obstruct the air inlet and air outlet vents, it may cause low performance or breakdown. Please remove obstacles to
assure the ventilation.
• During winter, please clean and remove the snow near outdoor unit so that the snow does no cover the air inlet and air
outlet vents.
INSPECTION
• In order to ensure optimal performance of the unit, seasonal inspections on the unit and fi eld wiring have to be carried out
at regular intervals. This maintenance should be carried out by authorized dealer.
• Clear any obstruction at the air inlet and air outlet vents of outdoor unit.
FOR EXTENDED NON-USE
• Turn off the power supply.
NON SERVICEABLE CRITERIAS
NON SERVICEABLE CRITERIAS
TURN OFF POWER SUPPLY then please consult authorized dealer under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the control panel.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.

ENGLISH
9
TROUBLESHOOTING
The following symptoms do not indicate malfunction.
The following symptoms do not indicate malfunction.
CAUSE
Flowing sound during operation. ► • Refrigerant fl ow inside the unit.
Operation is delayed a few minutes after restart. ► • The delay is a protection to the unit’s compressor.
Outdoor unit emits water/steam. ► • Condensation or evaporation occurs on pipes.
Outdoor unit emits steam during heating mode. ► • This is due to defrost operation happens at the heat
exchanger.
Outdoor unit does not operate. ► • When the outdoor temperature is out of the operation
condition range, the heatpump system enter protection
control.
System diffi cult to heat-up. ► • When heating is operated by indoor unit together with
fl oor heating or panel heater simultaneously, there
may be case where warm water temperature is getting
lower and cause fl oor heating or panel heater heat-up is
weaken.
• When outdoor air temperature is low, it may be diffi cult to
get warm.
• Is the snow pile blocking the discharge outlet or intake
inlet of outdoor unit.
• When water outlet set temperature is low, it may be
diffi cult to get warm.
System cannot get warm instantly. ► • Due to the nature of the heatpump system, it may take
some time to heat-up the water if the unit is operated
from cold-start.
Operation starts after power resumes. ► • Unit is operates under auto restart function.
Check the following before calling for servicing.
Check the following before calling for servicing.
CHECK
Heating operation is not working effi ciently. ► • Set the temperature correctly.
• Is the panel heater valve closed.
• Clear any obstruction at the air inlet and air outlet vents
of outdoor unit.
Noisy during operation. ► • Check if the unit has been installed at an incline or the
cover is not closed properly.
The unit does not work. ► • Check if the circuit breaker is tripped.
Operation LED is no lit or control panel display
is blank.
► • Is the power supply off or power failure.
The operation LED blinks and error code appear on control panel display.
The operation LED blinks and error code appear on control panel display.
TIMER
TIMER
1
MON TUEWEDTHU FRI SAT SUN
2 3 4 5 6
ON
OFF
• Turn the unit off and reveal the error code to authorized dealer.
• Timer operation cancel when error code occur.
Force Heater Mode Button
FORCE
• In case of a failure of the Air-to-Water Heatpump system, the backup heater can be used to heat
up the heating water. Press
FORCE
to switch on the backup heater.
• Press
OFF
/
ON
to stop the force heater operation.
• During Force Heater mode, all other operations are not allowed.

10
• Ce manuel décrit comment utiliser le système de pompe à chaleur
entre les unités intérieure et extérieure seulement.
• Pour le fonctionnement d’autres systèmes tels que le réservoir d’eau,
le radiateur, le contrôleur thermique externe et le chauffage au sol,
référez-vous aux modes d’emploi de leurs fabricants respectifs.
CONSIGNES DE SÉCURITÉ
TABLE DES MATIÈRES
CONSIGNES DE SÉCURITÉ
10~11
PANNEAU DE COMMANDE
12~15
UNITÉ INTÉRIEURE
16
DÉPANNAGE
17
INFORMATIONS
34~35
REMARQUE
Les illustrations de ce mode d’emploi
sont fournies à titre d’exemple
uniquement et peuvent présenter des
différences par rapport à l’appareil
proprement dit. Celui-ci peut être
modifi é sans préavis à des fi ns
d’amélioration.
CONDITION D’UTILISATION
Température de
sortie d’eau (°C)
Unité
intérieure
CHAUFFAGE
Max. 55
Min. 25
Température
ambiante (°C)
Unité
extérieure
CHAUFFAGE
Max. 35
Min. -20
ATTENTION: Si la température extérieure sort
de la plage de températures
ci-dessus, la capacité thermique
chutera de façon importante et
il se peut que l’unité extérieure
s’arrête pour le contrôle de
protection.
Pour éviter des blessures corporelles sur vous-même et sur les autres ou
des dégâts matériels, respectez les instructions ci-dessous.
Tout dysfonctionnement dû au non-respect des instructions peut
occasionner des nuisances ou des dégâts dont la gravité est classée
comme décrit ci-après:
AVERTISSEMENT
Ce symbole signale la présence d’un
danger pouvant provoquer des blessures
graves ou mortelles.
ATTENTION
Ce symbole signale la présence d’un
danger pouvant provoquer des blessures
corporelles ou des dégâts matériels.
Les instructions à respecter sont classées d’après les symboles suivants:
Ce symbole désigne une action
INTERDITE.
Ces symboles désignent des
actions OBLIGATOIRES.
UNITÉ INTÉRIEURE ET UNITÉ EXTÉRIEURE
UNITÉ INTÉRIEURE ET UNITÉ EXTÉRIEURE
Cet appareil n’est pas conçu pour être utilisé par des personnes
(y compris les enfants) aux capacités physiques, sensorielles
ou mentales diminuées, ou manquant d’expérience ou de
connaissances, sauf si une personne responsable de leur
sécurité leur a expliqué le fonctionnement de l’appareil et les
garde sous surveillance. Les enfants doivent être supervisés afi n
qu’ils ne jouent pas avec l’appareil.
Veuillez consulter un revendeur agréé ou un spécialiste pour la
réparation, l’installation, le retrait ou le déménagement de l’unité.
Une installation et une manipulation incorrectes pourraient
occasionner des fuites, un choc électrique ou un incendie.
N’installez pas l’appareil dans une atmosphère potentiellement
explosive ou infl ammable. Sinon, il y a un risque d’incendie.
N’insérez jamais vos doigts ou des objets dans
l’unité intérieure ou extérieure du climatiseur, les
parties tournantes peuvent causer des blessures.
Ne touchez pas l’unité extérieure au cours d’un orage, cela
pourrait provoquer un choc électrique.
N’essayez pas de réparer l’appareil vous-même. Vous
pourriez vous blesser en cas de mauvaise manipulation.
N’installez pas l’unité intérieure à l’extérieur. Elle est
uniquement conçue pour une installation en intérieur.

UNITÉ INTÉRIEURE ET UNITÉ EXTÉRIEURE
UNITÉ INTÉRIEURE ET UNITÉ EXTÉRIEURE
Ne nettoyez pas l’unité intérieure avec de l’eau,
du benzène, du solvant ou de la poudre à récurer.
N’installez pas l’unité à proximité d’un
équipement combustible ou dans une salle de
bains. Sinon, il y a risque de choc électrique ou
d’incendie.
Ne touchez pas le tuyau d’évacuation d’eau de
l’unité intérieure pendant le fonctionnement.
Ne posez rien sur ou sous l’unité.
Ne vous asseyez pas et ne montez
pas sur l’unité, vous risquez de
tomber accidentellement.
Ne touchez pas l’ailette pointue
d’aluminium, les parties pointues
peuvent causer des dommages.
Assurez-vous que le tuyau de vidange est
correctement raccordé. Sinon, une fuite peut
se produire.
Vérifi ez régulièrement le rack d’installation pour
vous assurer qu’il n’est pas endommagé. Après
de longues périodes d’utilisation, la solidité du
rack d’installation peut être amoindrie.
PANNEAU DE COMMANDE
Ne laissez pas le panneau de commande
prendre l’humidité. Sinon, il y a risque de choc
électrique ou d’incendie.
N’appuyez pas sur les touches du panneau de
commande à l’aide d’objets durs et pointus.
Vous pourriez endommager l’unité.
Ne nettoyez pas le panneau de commande
avec de l’eau, du benzène, du diluant ou de la
poudre à récurer.
N’inspectez pas et n’entretenez pas le panneau
de commande vous-même. Consultez un
revendeur agréé. Sinon, vous pourriez vous
blesser en cas de mauvaise manipulation.
AVERTISSEMENT
ALIMENTATION
N’utilisez pas de cordon modifi é,
de raccords, de rallonge ou de
cordon non spécifi é afi n d’éviter
une surchauffe et un incendie.
Ne partagez pas la même prise d’alimentation
qu’un autre équipement afi n d’éviter une
surchauffe et un incendie.
N’utilisez pas l’appareil pas avec les mains
mouillées afi n d’éviter un choc électrique.
Si le cordon d’alimentation est endommagé, il doit
être remplacé par le fabriquant, par un de ses
techniciens ou par une personne qui possède des
qualifi cations équivalentes afi n d’éviter tout risque.
Cette unité est équipée d’un disjoncteur de
courant résiduel (RCCB). Il est fortement conseillé
de faire contrôler le fonctionnement du RCCB
après l’installation et périodiquement après
l’entretien ou la maintenance par un revendeur
agréé afi n de garantir son bon fonctionnement.
Sinon, il y a risque de choc électrique ou
d’incendie en cas de dysfonctionnement.
Il est conseillé de porter des gants pendant la
maintenance ou l’entretien afi n d’éviter tout risque.
Cet équipement doit être raccordé à la terre afi n
d’éviter un choc électrique ou un incendie.
En cas d’urgence ou dans des conditions anormales
(odeur de brulé, etc.), débranchez l’alimentation
électrique et contactez le revendeur autorisé.
Prévenez les chocs électriques coupant
l’alimentation:
- Avant le nettoyage ou l’entretien.
- En cas de non-utilisation prolongée.
- En cas d’activité orageuse anormalement forte.
Cet appareil convient à de multiples usages.
Tous les circuits d’alimentation électrique doivent
être coupés avant toute intervention sur les
bornes de l’unité intérieure, afi n d’éviter tout choc
électrique, brûlure ou blessure mortelle.
Chauffage au sol
Panneau
Panneau de commande
Alimentation
Réservoir d’eau
Unité Intérieure
Unité Extérieure