Dimplex KX03001 User Manual

Installation and Operating Instructions
Key Switch
08/18964/0 - Issue 0
Model No. KX03001
DIMENSIONS (millimetres)
70mm 35mm
117mm
THESE INSTRUCTIONS SHOULD BE READ CAREFULL Y AND RET AINED FOR FUTURE REFERENCE GENERAL DESCRIPTION
The KX03001 can be used in conjunction with the Dimplex PLX, SPX, EVS, EVX, RPX and Calidou panel heaters. The unit is designed to be flush mounted to a single BS backing box using the adaptor plate provided. The unit comprises 2 x 20 Amp (250VAC) rated single pole changeover mechanisms, together with a neon that is designed to provide an easily visible backlit card pocket.
Important Safety Advice
Do not use this appliance in the
immediate surroundings of a bath, a shower or swimming pool.
Do not use where excessive dust or
moisture is present.
This unit must only be used on an
A.C. Mains supply of 230/240V .
For use in normal pollution situations
only.
Note 1:
When the fob is removed a neon will light to aid the user, whether used in On/Off or Pilot Wire installations.
Note 2:
This unit contains a second 20 Amp rated mechanism to allow another device to be switched (e.g. lighting).
OPERATING INSTRUCTIONS
Dependant on the heater used and wiring, the KX03001 can operate in either On/Off switching mode, or in Pilot Wire mode when used with a suitable heater.
ON/OFF SWITCHING
Using the key fob provided, place the fob into the pouch to switch the heater On. Removing the fob isolates the power and turns the heater Off.
PILOT WIRE SWITCHING
Using the key fob provided, place the fob into the pouch to switch the heater to its comfort temperature setting. Removing the fob switches the heater to its background temperature
setting when the room is unoccupied.
INSTALLATION
Before undertaking installation work, ensure the electricity supply is disconnected from any fixed wiring.
All wiring should be carried out by a qualified
Electrician in accordance with the current IEE Wiring Regulations.
This unit is designed for fitting to a standard
single BS backing box with a depth of 25mm.
Please ensure the top and bottom lugs are
removed, if fitted, from metal wall boxes prior to fitting.
Ensure that there is adequate space for wiring.
Please see the following diagrams for your
chosen connection type (On/Off, Pilot Wire).
CONTINUED OVERLEAF
CONNECTIONS AND WIRING DIAGRAM
21 C
L
O
O
P
1
L
O
O
P
1
C
2
NEON
2-WAY INTERNAL
2
L
O
C
1
21
L
O
P
O
O
P
C
1
SWITCHES
TERMINAL CONNECTIONS
NEON INDICATOR UNIT
WIRE TO LIVE FEED
1 = WIRE TO NEUTRAL
ON/OFF SWITCHING USING 2-WAY INTERNAL SWITCH UNIT
2 = LIVE TO NEON C = LIVE INPUT
LOOP = NEUTRAL 1 = LIVE OUTPUT
PILOT SWITCHING USING 2-WAY INTERNAL SWITCH UNIT
2 = PILOT WIRE & LIVE TO NEON C = LIVE INPUT
BACK VIEW
GENERAL CLEANING
The outside of the unit should be wiped over with a soft damp cloth only. Do not use detergents or abrasives.
AFTER SALES SERVICE
Your Dimplex product is guaranteed for one year from the date of purchase. We undertake to exchange this product free of charge within this period if found to be defective and only when used as per instructions. Should you require after sales service, please contact the Dimplex customer help desk listed below. Please do not initially return a faulty product, as this may result in loss or damage which can cause delay in providing service. Let us know your difficulty quoting the model number and we will then take the appropriate action.
Glen Dimplex UK Ltd.
Millbrook House, Grange Drive Hedge End, Southampton Hampshire SO30 2DF
LOOP = NEUTRAL
1 = NOT CONNECTED
C = COMMON TERMINAL 1 = NORMALLY OPEN TERMINAL 2 = NORMALLY CLOSED TERMINAL LOOP = NOT CONNECTED
Tel: Customer Services 0870 727 0101 Fax: Customer Services 0870 727 0102 Email: customer.services@glendimplex.com Website: www.dimplex.co.uk
Loading...