THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
(IP24)
IMPORTANT SAFETY ADVICE
Because the IRXE Heater contains no moving
parts, little maintenance is required. Before
undertaking any maintenance work on the
heater, due attention must be paid to the
following:
This heater is designed to be horizontally wall
mounted only, it must not be ceilingmounted.
Always ensure a safe mounting height, at or
above a minimum height of 1.8 metres from
ground level, so that the heater can not be
touched when in operation.
Always ensure a safe means of access using
an access tower or properly supported ladder.
DO NOT cover the heater.
Keep combustible materials away from the
heater.
DO NOT look into the heater for prolonged
periods.
DO NOT use the heater if the elements are
broken - as injury may occur.
The heater must be wall mounted level ± 5º
to the horizontal.
This appliance can be used by children
aged from 8 years and above and persons
with reduced physical, sensory or mental
capabilities or lack of experience or knowledge
if they have been given supervision or
instruction concerning the use of the
appliance in a safe way and understand the
hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be
made by children without supervision.
Children of less than 3 years should be kept
away unless continuously supervised.
Children aged from 3 years and less than 8
years shall only switch on/o the appliance
provided that it has been placed or installed
in its intended normal operating position
and they have been given supervision
or instruction concerning the use of the
appliance in a safe way and understand the
hazards involved.
Allow adequate time (minimum of 30 mins.)
for the elements and body casing to cool
before attempting to work on the heater.
DO NOT allow the supply cord to sit or hang
in front of the heater while in use.
NOTE: Provide sucient slack to the cable
to allow for angular adjustment of the body.
The bulbs are extremely fragile and must be
handled with extreme care at all times. If the
bulb is accidentally touched by bare fingers
remove the fingerprint with a soft cloth
moistened with methylated spirits.
DO NOT use this heater in the immediate
surroundings of a bath, shower or a swimming
pool.
This device is not fitted with equipment for
regulating room temperature. The heater
must not be used in small rooms occupied by
people who cannot leave the room without
assistance unless continuous monitoring is
guaranteed.
Children aged from 3 years and less than 8
years shall not plug in, regulate and clean the
appliance or perform user maintenance.
DO NOT locate the heater immediately above
or below a fixed socket outlet or connection
box.
Always disconnect the heater from the
electricity supply before attempting to work
on or near it.
Some parts of this product can become very
hot and cause burns. Particular attention has
to be given where children and vulnerable
people are present.
Connection only to fixed installed cables!
The hardwired electrical installation must
be provided with a disconnect device with a
contact grap of at least 3 mm at each pole
(e.g. automatic circuit breaker)!
Fig. 2Fig. 1
Fig. 3
300
mm
400mm
600mm
1800mm
Fig. 4
255mm
General
The IRXE range of infra-red wall heaters are a safe, practical
source of heat in bathrooms, kitchens, work areas - anywhere
where fast localised heating is required. The IRXE uses quartz
elements which emit a warm glow of medium wave infra-red.
The IP24 rating means the appliance is suitably rated to be
permanently installed either internally or externally.
Technical Details
Model Identifier(s):IRX60/120E
Nominal voltage230-240V~
Degree of ProtectionIP24
Dimensions (W x H x D)768 x 100 x 92
a. Remove the screw (a) to release the plastic control molding.
This will allow the unit to tilt forward and allow access to the
securing holes on the back of the unit - see Fig. 3.
b. Place heater horizontally against the wall, mark and drill holes
to suit and insert the two wall fixings supplied - see Fig. 3
c. Place the two plastic inserts into the holes provided on the
control housing and tighten screws to secure heater - see Fig. 3
Replace control molding and fix heater to required angle.
The bracket allows the heater to be inclined at the required
angle. The siting of the heater(s) should be such as to allow an
even and uninterrupted distribution of radiation to the area(s)
to be heated. Heaters are most eective when the beam angle is
inclined down at an angle of between 30º to 45º to the vertical.
When deciding upon the best location, consideration must be
given to the following requirements:
Weight1.6kg
Heat Output
Nominal heat outputPnom1.2kW
Minimum heat output
(indicative)
Maximum continuous
heat output
Intrinsic Consumption
At nominal heat outputelmax0.00
At minimum heat outputelmin0.00
In standby modeelSB
Control for heat output
Two manual stages, no room temperature control
Pmin0.6kW
Pmax, C1.2kW
<0.0005
Electrical Connection
The installation of this appliance should be carried out by a
competent electrician and be in accordance with the current
IEE wiring regulations and any local or insurance regulations.
The IRXE is designed for use on a 230-240V AC single phase
supply. A double pole isolating switch with a minimum separation
of 3mm in each pole must be fitted to facilitate isolation. This
switch must either be positioned inside a building or have an IP
rating against water ingress suitable for external installation. The
appliance must be supplied through a residual current device
(RCD) having a rated residual operating current not exceeding
30mA. The appliance must be connected to a socket-outlet
having an earthing contact (for Class I appliances).
Remove Packaging (See Fig. 1)
Prior to installation remove the polystyrene inserts which secure
the elements during transportation.
a. Remove the two front grill screws.
b. Remove the front grill in the direction of the arrow.
c. Remove element protection polystyrene.
Replace front grill and reverse procedure.
Installation - Wall Mounting
The heater must be permanently fixed to the wall using the
wall mounting bracket and screws supplied. The heater must
be mounted Horizontally as shown observing the minimum
clearances stated in Fig. 2.
The minimum mounting height for the heater is 1.8 meters which
requires that the the mounting holes for the wall bracket be
drilled at a height of 1.9 meters.
a. Comfort and safety could be compromised unless the heater
is mounted at or above 1.8m from ground level.
b. The minimum clearance distances must be maintained as
shown in Fig. 2.
Operation
The desired heating level can be set by pulling the pull cord
switch once or repeatedly. The set heating level can be read in the
display window. In position “0” the heating device is switched o.
Power output in switch position:
ModelDisplay 0Display 1Display 1Display 2
IRX60/120EO600W600W1200W
W = output power in Watts
Element Replacement (see Fig.4)
WARNING: BEFORE UNDERTAKING THIS TASK, ENSURE
THE HEATER IS DISCONNECTED FROM THE ELECTRICITY
SUPPLY AND LEFT TO COOL FOR A MINIMUM OF 30
MINUTES
1. Remove the two screws which hold the front grill onto the
heater.
2. Remove the front grill in the direction of the arrow.
3. Remove the two element securing clips to release the element.
4. Disconnect the element wires from each side of the element.
5. Reverse procedure with new element.
Cleaning & User Maintenance
WARNING: BEFORE UNDERTAKING CLEANING OR
MAINTENANCE WORK ON THE APPLIANCE, DISCONNECT
THE ELECTRICITY SUPPLY
Since the appliance contains no moving parts little maintenance
is required beyond cleaning and element replacement. It is
however essential that the heater is not operated with an
accumulation of dust or dirt on the element, as this can cause a
build up of heat and eventual damage. For this reason the heater
must be inspected regularly, depending upon conditions and at
least at yearly intervals. Allow adequate time for the element and
body casing to cool before attempting to work on the heater - a
minimum time of 30 minutes is recommended.
If the bulb is accidentally touched by bare fingers remove the
fingerprint with a soft cloth moistened with methylated spirits.
Recycling
For electrical products sold within the European
Community. At the end of the electrical products
useful life it should not be disposed of with household
waste. Please recycle where facilities exist. Check with
a Local Authority or retailer for recycling advice in your
country. Batteries should be disposed of or recycled in
accordance with WEEE Directive 2012/19/EU. Packaging
should be recycled where possible.
What does a Dimplex Warranty Cover?
Dimplex products deliver reliable service for normal, household use in
domestic settings. All Dimplex products are individually tested before
leaving the factory.
If you are a consumer and you experience a problem with your Dimplex
product, which is found to be defective due to faulty materials or
workmanship within the Warranty Period, this Dimplex Warranty will
cover repair or - at the discretion of Dimplex – replacement with a
functionally equivalent Dimplex product.
The Dimplex Warranty Period is two calendar years from the date of
purchase of your Dimplex product, or the date of delivery of the product,
if later. The Dimplex Warranty is conditional upon you providing the
original purchase receipt as proof of purchase. Please therefore retain
your receipt as proof of purchase.
If you do experience a problem with your Dimplex product please call the
Helpline on +44 [0]344 879 3588 or visit https://www.dimplex.co.uk/
support. For ROI please email serviceireland@glendimplex.com or call
+353(0)1 842 833. We will need details of your Dimplex product, its serial
number and a description of the fault which has occurred. You can find
the model number and serial number for your Dimplex product on the
heaters side. Once we receive your information and proof of purchase
we will contact you to make the necessary arrangements.
If your Dimplex product is not covered by this Dimplex Warranty there
may be a charge to repair your product. However, we will contact you for
agreement to any charges before any chargeable service is carried out.
What is not covered by a Dimplex Warranty?
The Dimplex Warranty does not cover any of the following:
• Any fault or damage to your Dimplex product due to faulty materials
or workmanship occurring outside the two-year Warranty Period.
• Any fault or damage occurring to any pre-owned Dimplex product or
to any other equipment or property.
• Accidental damage to your Dimplex product or damage to your
Dimplex product from external sources (for example, transit, weather,
electrical outages or power surges).
• Fault or damage to your Dimplex product which is:
• Not due to faulty materials or workmanship or which is due to
circumstances outside Dimplex’s control.
• Caused by use of your Dimplex product for anything other than normal
domestic household purposes in the country where it was purchased.
• Caused by any misuse, abuse or negligent use of the Dimplex product,
including but not limited to any failure to use it in accordance with the
Operating Instructions supplied with the product.
• Caused by any failure to assemble, install clean and maintain your
Dimplex product in accordance with the Operating Instructions
supplied with the product unless this was carried out by Dimplex or
its authorised dealers.
• Caused by repairs or alterations to your Dimplex product not carried
out by Dimplex service personnel or its authorised dealer(s).
• Caused by use of any consumables or spare parts for your Dimplex
product which are not Dimplex -specified.
Terms and Conditions
• The Dimplex Warranty is valid for Dimplex from the date of purchase
of your Dimplex product from a recognised retailer in the country of
purchase and use, or the date of delivery of the product if later, always
provided the original receipt has been retained and is produced as
proof of purchase.
• You must provide to Dimplex or its authorised agents on request the
original receipt as proof of purchase and - if required by Dimplex - proof
of delivery. If you are unable to provide this documentation, you will
be required to pay for any repair work required.
• Any repair work under the Dimplex Warranty will be carried out by
Dimplex or its authorised dealer(s) and any parts that are replaced will
become the property of Dimplex. Any repairs performed under the
Dimplex Warranty will not extend the Warranty Period.
• Any replacement of your Dimplex product by Dimplex during the
Warranty Period will start the two-year Warranty Period afresh from
the date of delivery of the replacement Dimplex product to you.
• The Dimplex Warranty does not entitle you to recovery of any indirect
or consequential loss or damage including but not limited to loss or
damage to any other property.
• The Dimplex Warranty is in addition to your statutory rights as a
consumer and your statutory rights are not aected by this Dimplex
Warranty.
This product complies with the European Safety Standards EN60335:2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014:1, EN55014:2, EN61000:3-2
and EN61000:3-3 which cover the essential requirements of EMC Directive 2014/30/EU and the LVD Directive 2014/35/EU.
Glen Dimplex Heating & Ventilation