![](/html/92/921d/921d23a0d0942f6ab1cbf6711a97bd9d21146171462fd7df9bf8a111c56cf32b/bg1.png)
– 1 –
16L & 20L DEHUMIDIFIERS
INSTRUCTION MANUAL
GDDEK series (GDDEK16 and GDDEK20)
![](/html/92/921d/921d23a0d0942f6ab1cbf6711a97bd9d21146171462fd7df9bf8a111c56cf32b/bg2.png)
– 2 –
Please take time to read this manual carefully before use and
save it for future reference.
CONTENTS
Specifications 2
Before use 3
Control Panel 4
Operation 5
Where to position 6
Parts 7
How it works 8
Drainage 9
Maintenance 10
Trouble shooting 11
SPECIFICATIONS
Model no. GDDEK16 GDDEK20
Power supply 220-240V~, 50Hz
Dehumidification capacity 30oC, 80% 16 L/day 20L/day
Power / Ampere consumption*
30oC, 80% 240W / 1.1A 370W / 1.7A
32oC, 80% 260W / 1.2A 390W / 1.8A
Air volume (max.) 150M3/h 150M3/h
Compressor Rotary
Refrigerant R134a
Working range 5 ~ 32oC
Water tank 5L
Size (WxDxH)
With castors - 336 x 210 x 569 mm
Without castors - 336 x 210 x 547 mm
N.W. 10.4 kg 11 kg
• *please refer to the rating label placed on the product.
• Test condition for data in our rating label is as per safety regulation: EN 60335-2-40
![](/html/92/921d/921d23a0d0942f6ab1cbf6711a97bd9d21146171462fd7df9bf8a111c56cf32b/bg3.png)
– 3 –
BEFORE USE
CAUTION!
l
Always keep the unit in vertical position.
l
Leave the unit to stand for one hour before connecting to the mains supply after
transport or when it has been tilted (e.g. during cleaning).
l
Keep all foreign objects away from the air intake or output openings.
l
The mains supply must conform to the specification shown on the rating plate at the
back of the unit.
l
If the supply cord is damaged, it must be replaced by an approved service
representative or a similar qualified person.
l
Never use the plug to start and stop the unit. Always use the button on the control
panel.
l
Before moving the unit, first switch off, then unplug and empty the water tank.
l
Don’t use bug sprays or other flammable cleaners on the unit.
l
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
IMPORTANT!
Do not use this unit at ambient temperatures below 5oC, to prevent the possibility of a
heavily iced up evaporating coil.
![](/html/92/921d/921d23a0d0942f6ab1cbf6711a97bd9d21146171462fd7df9bf8a111c56cf32b/bg4.png)
– 4 –
CONTROL PANEL
1. Humidity setting button
2. Working mode indicator (continuous
dehumidifying, humidity 40%, 50%,
60%, 70%). Ideal room humidity is
50%-60%.
3. Humidity/Temperature/Timer display
4. Timer operation indicator
5. Show temperature/ humidity display
button
6. Clothes drying mode indicator
7. Clothes drying button
8. High ventilation speed indicator
9. Ventilation speed button
10. Low ventilation speed indicator
11. Power indicator
12. ON/OFF (power) button
13. “Full Water Tank” indicator
14. TIMER set button
z
CONT.
TEMPERATURE
/HUMIDITY