Dimplex FXL18i, FXL24i User Manual

10887
FXL(i) FAN STORAGE HEATER RANGE
MODELS: FXL18i - 2.6kW / 18kWh STORAGE & 1.5kW BOOST
FXL24i - 3.4kW / 24kWh STORAGE & 1.5kW BOOST
INSTALLATION AND OPERATING
INSTRUCTIONS
IMPORTANT
PLEASE READ THIS LEAFLET CAREFULLY AND RETAIN FOR FURTHER USE.
NOTE ALSO THE INFORMATION GIVEN ON THE HEATER
A means for disconnection must be incorporated in the xed wiring in accordance with the said rules.
The heater must not be installed immediately below a xed socket outlet.
Do not position the heater under windows where curtains can contact the heater casing. Maintain a minimum
distance of 150mm at all times between the heater and combustible materials, such as furniture and curtains.
WARNING in order to avoid overheating, do not cover the heater. Do not place objects in contact with the heater.
WARNING - THE SURFACES ON THIS HEATER CAN BE HOT.
This heater meets AS/NZS 60335 electrical safety requirements. However, any heater type becomes hot in normal
operation. Care must be taken to ensure that prolonged skin contact with the heater does not occur.
WHERE YOUNG CHILDREN, INFIRM PERSONS, OR THE AGED ARE PRESENT THIS APPLIANCE MUST BE
ADEQUATELY GUARDED. Contact your installer or the manufacturer for further advice.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision for instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
This appliance is very heavy and must be securely fi xed to a wall. DO NOT UNDER ANY CIRCUMSTANCES
ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING EXPERT ADVICE.
To maintain stability, it is essential that the heater is placed on a level surface and care should be taken to avoid
irregular surfaces, such as may result from carpets or tiled surrounds partially protruding under the heater.
This heater must be installed where it is impossible for switches and other controls to be touched by a person using
a bath or shower.
IMPORTANT - Due to the newness of materials the heater will produce a slight smell for the fi rst few days of
operation. ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN, CAGED BIRDS, OR PERSONS WITH RESPIRATORY COMPLAINTS MUST NOT REMAIN IN CLOSE PROXIMITY TO THE HEATER DURING THE FIRST 48 HOURS OF THE COMMISSIONING PERIOD.
IF, DURING ANY REASSEMBLY OF THE HEATER, A PART OF THE THERMAL INSULATION SHOWS DAMAGE
OR DETERIORATION WHICH MAY IMPAIR SAFETY, IT SHOULD BE REPLACED BY AN IDENTICAL PART.
INSTALLATION INSTRUCTIONS
STORAGE CIRCUIT
24i
18i
PREPARATION
The heater will arrive separately from its storage bricks, the following bricks will be required.
FXL18i - 12 bricks FXL24i - 16 bricks
IMPORTANT DURING NORMAL OPERATION ENSURE
BOTH SUPPLIES ARE SWITCHED ON AT THE WALL.
Two supplies are required for the operation of this heater - a restricted Off Peak or Economy 7 supply for the storage circuit, and an unrestricted supply for the fan boost element circuit. Thermostatic fan / boost control is provided on the heater, however the fan / boost operation may be customised by the introduction of an external timer to the heater (see section 3).
WARNING - This appliance
must be earthed
Only heat resisting cable (min. rating V75) should be used. The wires in the mains cable will be coloured as follows:-
GREEN & YELLOW - EARTH
BLUE - NEUTRAL
BROWN - LIVE
FAN/BOOST CIRCUIT
INSTALLATION
1. ENSURE THAT FIXING KIT HAS BEEN
LOCATED BEFORE DISPOSING OF PACKAGING. Remove the front panel by removing the three screws along its bottom edge. With hands positioned on each side of the panel, lift upwards to unhook the top edge whilst pressing down on the top panel with your thumbs. The panel can now be lifted clear and set to one side. Remove the packing pieces from the slots on the inner front (3 on the FXL18i and 4 on the FXL24i).
2. Remove the inner front panel by unscrewing the screws along its top and sides. As the front insulation is attached care must be taken when lifting this panel from the heater and placing it to one side. Remove the three inner guards by removing the screws along their bottom edges and sliding the guards up and off the base tray.
Please note the location of each guard.
3. CONNECTION OF THE MAINS CABLE
- Connect the restricted (E7) supply to the terminal block, marked “Storage Circuit”, having first passed the cable through a front cable clamp in the base. Connect the unrestricted (Peak) supply to the terminal block, marked “Fan/Boost Circuit”, having passed this cable through another cable clamp in the base. At this point, if desired, an external fan/ boost timer may be fi tted to the heater by passing the two wires from the timer through the remaining cable clamp, and connecting them across the terminal block, marked “Timer”, having already removed the link tted across this block at the factory.
IMPORTANT: When using an external fan/boost timer, the fan inhibitor must be disabled (see Section 4).
Connect the EARTH lead from both supplies to the terminal marked with the symbol
SUGGESTED FIXINGS
SOLID BRICK/BLOCK - No. 10 Size plastic
inserts, 8mm drill bit. Drill hole 15mm deeper than plastic insert length. PLASTERBOARD - If possible locate studding and use No. 10 woodscrews directly into the wood, otherwise M5 rawlplug intersets are suitable. NOTE: FOR OTHER WALL TYPES - (e.g. timberframe and hollow concrete) SEEK
SPECIALIST ADVICE.
Loading...
+ 2 hidden pages