Down-Flo Wall Heater
EWA-C, 1, 1.5, 2 kW Series
IMPORTANT INSTRUCTIONS
When using electrical appliances, basic precautions should
always be followed to reduce the risk of re, electric shock,
and injury to persons, including the following:
1. Read all instructions before using the heater.
2. The heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. The trim around the heater
outlet becomes hot during heater operation. Keep combustible materials, such as furniture, pillows, bedding,
papers, clothes, and curtains at least 3 ft (0.9 m) from the
front of the unit and keep them away from the sides and
rear.
3. Extreme caution is necessary when any heater is used
by or near children or invalids and whenever the unit is
left operating and unattended.
4. Do not operate any heater after it malfunctions. Disconnect power at the service panel and have the heater inspected by a reputable electrician before reusing.
5. Do not use outdoors.
6. To disconnect the unit, turn the controls off, and then
switch off at main power supply panel.
7. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric
shock or re, or damage to the heater.
8. To prevent a possible re, do not block air intake or exhaust in any manner.
9. All electrical heaters have hot and arcing or sparking
parts inside. Do not use in areas where gasoline, paint,
or ammable liquids are used or stored.
10. Do not modify this heater. Use it only as described in
this manual. Any other use not recommended by the
manufacturer may cause re, electric shock or injury to
persons.
SAVE THESE INSTRUCTIONS
Installation Instructions
WARNING: To reduce the risk of re, do not store or use
gasoline or other ammable vapors or liquids in the vicinity of
the heater.
CAUTION: High temperature, risk of re, keep electrical
cords, drapery, furnishings, and other combustibles at
least 3 feet (0.9 m) from the front of the heater.
Recessed Installation
1. Allow 12” (30cm) of service cable for connecting to wall
box. Remove 6” (15cm) of the outer jacket and strip the
individual conductors 1/4” (6mm) from the end.
2. Cut a wall opening 14 9/16” (37cm) high by 11 1/4”
(28.5cm) wide (see Figure 1). Allow a minimum of 2”
(5cm) clearance around wall opening to accomodate
heater frame. Depth of wall opening must be 3 1/4”
(8.3cm) minimum, measured from nished wall surface.
3. Remove the screws securing heater assembly to the wall
box and separate. Keep all screws for heater reassembly.
4. Remove rear knockout at top corner of wall box and
insert 1/2 cable connector. Bring service leads through
connector and secure end of cable to the connector.
5. For safety, each wall heater is provided with a grounding
screw located in the upper right corner of the wall box.
Connect ground lead and tighten screw for good electrical connection.
6. Place wall box in wall opening so the welded side brackets rest on nished wall surface, and secure box with
four #10 Philips head wood screws, 1 1/2” long (not provided). Insert the wood screws through the inner set of
ange holes at both top and bottom. Alternate holes are
provided in sides of box for mounting to wood framing.
(If wall box is installed prior to application of nished wall
surface, set box to allow for wall thickness).
!
NOTE: When mounting wall box to hard wall surface,
predrill mounting and clearance holes to prevent splitting wall
surface.
7. Check nameplate on heater to make sure you are con-
necting to the proper voltage. Remove any packing material or debris from the heater assembly and wall box.
Then connect service leads.
8. Place heater assembly into the wall box. Check fan to
see that it turns freely, and service leads are clear of fan
area. Secure heater assembly to the wall box with four
sheet metal screws (provided).
9. Carefully position grille over heater assembly so that protruding switch and thermostat shaft do not bind against
grille. Secure grille to heater assembly using two Phillips head sheet metal screws (provided). Push press-t
thermostat knob on shaft.
10. Install the frame to the grille, securing its upper back
edge behind the lip on the top of the wall box, and its
lower edge with the single screw.
11. Energize heater circuit and test heater (see operating
instructions).
Surface Installation
1. Allow 25” (63cm) of service cable for connecting the
heater (see Fig. 2). Remove all but 2” (5cm) of outer
jacket and strip individual conductors 1/4” (6mm) from
end.
2. Mount surface box to the wall using the four provided
#8 - 3/4” Philips head wood screws, inserted through
mounting holes on the back side anges. (For hard wall
surfaces, pre-drill mounting holes to prevent splitting wall
surface.)
3. Install 1/2 cable connector in hole on bottom of surface
boxnear right side. Feed service leads through and secure end of cable to the connector.
4. Remove the rear knockout on top of heater wall box near
right side and insert bushing (provided). Feed service
wires through bushing. Secure wall box to surface box
with four sheet metal screws (provided with the surface
box). Screws are inserted through the inside holes on
the anges.
5. Proceed with steps 7 through 11 inclusive in recessed
heater installation instructions.
Wiring
Two conductor non-metallic sheath cable with ground wire is
7204380100R07

Figure 1: RECESSED
GROUNDING SCREW
PHILLIPS HEAD
SCREW
3 1/4”MINIMUM
WALL OPENING
11 1/4”
12” CABLE
Figure 3
WALL STAT
(OPTIONAL)
GRILL
FRAME
OVERTEMP LIGHT
120/208/240V
HEATER
THERMOSTAT
KNOB
ASSEMBLY
recommended for recessed installation of these heaters while
two conductor, metallic sheath cable (BX) is recommended
for surface installations. Use number 12 gauge wire for all
models. Each heater should be on an individual, properly
fused circuit.
WARNING: Wiring procedures and connections should
be in accordance with the National Electric code (NEC) and
local codes.
1. When installing optional wall thermostat, unit mounted
thermostat must be set at it’s highest setting.
2. All external control equipment (shown with dashed lines)
furnished by customer. Control wiring must be suitable
for 600V.
3. Heater branch circuits shall have a carrying capacity of
no less than 125% of maximum load served.
Figure 2: Surface
GROUNDING
SCREW
SHEET METAL
SCREW
SURFACE
WALL BOX
REMOVE THIS
KNOCKOUT
HEATER WALL BOX
25” SERVICE
LEADS
SERVICE CABLE
WALL BOX
WALL
OPENING
14 9/16”
REMOVE THIS
KNOCKOUT
ELECTRICAL
SERVICE
PER NAMEPLATE
SWITCH
GRID
FAN
CONTROL
ALARM
LIGHT
120/208/240V
THERMOSTAT
LIMIT
CONTROL
THERMOSTAT
Operation
WARNING: This heater must be properly installed before
it is used.
These heaters are operated by an on/off switch and also a
temperature control with a knob.
1. Turn the switch ON. Remember there is a fan delay.
2. Set thermostat by turning the knob to desired room com-
fort level (clockwise to increase heat output). Once you
have determined the proper setting to provide the heat
level you prefer, you need not touch the knob again.
3. Turn the switch OFF to turn off heater. To reuse, simply
turn the switch ON - the temperature level you wish has
been previously set.
!
NOTE: This heater is equipped with a fan delay switch
which delays the fan operation until the heating grid has
heated sufciently to assure the circulation of only warm air.
This same switch permits the fan to operate after power to
the grid has been shut off by thermostat action, thus utilizing
all the heat remaining in the grid.
When the heater is shut down by turning the switch OFF,
power to both fan motor and element is diconnected and the
fan motor will not continue to operate.
WARNING:Should the OVERTEMP light come on,
disconnect power to the heater, turn the switch OFF or
turn down the thermostat fully counterclockwise and call
a licenced electrician. DO NOT USE HEATER UNTIL
PROBLEM IS DETERMINED AND FIXED.
Tamper Proof Models
The ON/OFF switch and the temperature regulating thermostat are recessed so that the continuous grille front panel can
be installed concealing both controls. The thermostat is operated by removing the front panel. The ON/OFF switch can
be operated by inserting a slender non metallic rod between
grill louvers and turning the switch ON or OFF.
www.dimplex.com2

Maintenance
WARNING: Disconnect power and heater has cooled
before attempting any maintenance or cleaning to reduce
the risk of re, electric shock or damage to persons.
!
NOTE: This heater should not be operated with an ac-
cumulation of dust or dirt on or in the unit, as this can cause
a build up of heat and eventual damage. For this reason the
heater must be inspected regularly, depending upon conditions and at least at yearly intervals.
CAUTION: Before removing heater parts, open branch
service switch or remove fuses. These are located at the
distribution panel.
To clean, remove frame, grille and heater assembly. Remove
any dust and dirt from wall box and heater assembly with a
soft cloth or brush, then re-install heater assembly making
sure that the fan turns freely and service leads are away from
fan area. The frame and grille may be washed with a mild
detergent, however make sure they are thoroughly rinsed
and dried before re-installation.
Warranty
The Manufacturer warrants the heating elements and components
of the enclosed product against any defect in material or
workmanship for a period of one year from the date of purchase. In
full satisfaction of any claims under this Warranty the Manufacturer
will repair or replace without charge, in its factory or in the eld as it
alone may decide, any parts which in its opinion are defective.
The Manufacturer shall not be responsible for any transportation
or shipping costs in relation to such repair or replacement except
as specically assumed by it. Misuse of this product or repairs by
persons other than the Manufacturer’s authorized personnel without
the Manufacturer’s written approval, will void this Warranty.
This Warranty is in lieu of all other warranties or conditions
whether express or implied including but not limited to those of
merchantability or tness for purpose and shall constitute the sole
remedy of the Purchaser and the sole liability of the Manufacturer in
respect of the sale of the product, whether in the nature of breach or
breach of fundamental term, or of negligence or otherwise.
The Manufacturer shall not be liable for any special, indirect or
consequential damages or for any damages resulting from removal
or replacement of a heater subject to warranty claim without the
Manufacturer’s authorization.
This Warranty is transferable by the original consumer purchaser
of the product. Any claims under this Warranty must be submitted
in writing to the Service Manager, Dimplex North America Ltd., 1367
Industrial Rd., Cambridge, Ontario N1R 7G8, Canada.
Replacement Parts
Fan Blade .................................. 5300180159RP
Cut Out .................................... 02005028RP
Fan Delay .................................. 02002910RP
Thermostat ................................. 2600060100RP
Grill ....................................... 1019040168RP
Knob ...................................... 8800540468RP
CATALOGUE
NO.
EWA10C11 2000250400RP 3200070500RP 2200361200RP
EWA10C31 2200361400RP
EWA10C41 2000250300RP 3200070300RP 2200361100RP 2800071300RP
EWA15C11 2000250400RP 3200070500RP 2200220500RP
EWA15C31 2200220100RP
EWA15C41 2000250300RP 3200070300RP 2200220400RP 2800071300RP
EWA20C21
EWA20C31 2200220300RP
EWA20C41 2000250300RP 3200070300RP 2200220100RP 2800071300RP
MOTOR CAPACITOR ELEMENT SWITCH
2000250200RP 3200070400RP
2000250200RP 3200070400RP
2000250200RP 3200070400RP
2200361300RP
2200220300RP
2200220200RP
2800071200RPEWA10C21
2800071200RPEWA15C21
2800071200RP
1367 Industrial Road Cambridge ON Canada N1R 7G8
1-888-346-7539 www.dimplex.com
In keeping with our policy of continuous product improvement, we reserve the right to make changes without notice.
© 2013 Dimplex North America Limited