Dimplex EWA10C11, EWA10C21, EWA10C31, EWA10C41, EWA15C11 Installation Instructions Manual

...
Down-Flo Wall Heater EWA-C, 1, 1.5, 2 kW Series
IMPORTANT INSTRUCTIONS
When using electrical appliances, basic precautions should always be followed to reduce the risk of re, electric shock, and injury to persons, including the following:
1. Read all instructions before using the heater.
2. The heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. The trim around the heater outlet becomes hot during heater operation. Keep com­bustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 3 ft (0.9 m) from the front of the unit and keep them away from the sides and
rear.
3. Extreme caution is necessary when any heater is used
by or near children or invalids and whenever the unit is left operating and unattended.
4. Do not operate any heater after it malfunctions. Discon­nect power at the service panel and have the heater ins­pected by a reputable electrician before reusing.
5. Do not use outdoors.
6. To disconnect the unit, turn the controls off, and then switch off at main power supply panel.
7. Do not insert or allow foreign objects to enter any venti­lation or exhaust opening as this may cause an electric shock or re, or damage to the heater.
8. To prevent a possible re, do not block air intake or ex­haust in any manner.
9. All electrical heaters have hot and arcing or sparking parts inside. Do not use in areas where gasoline, paint, or ammable liquids are used or stored.
10. Do not modify this heater. Use it only as described in this manual. Any other use not recommended by the manufacturer may cause re, electric shock or injury to
persons.
SAVE THESE INSTRUCTIONS
Installation Instructions
WARNING: To reduce the risk of re, do not store or use
gasoline or other ammable vapors or liquids in the vicinity of
the heater.
CAUTION: High temperature, risk of re, keep electrical
cords, drapery, furnishings, and other combustibles at least 3 feet (0.9 m) from the front of the heater.
Recessed Installation
1. Allow 12” (30cm) of service cable for connecting to wall box. Remove 6” (15cm) of the outer jacket and strip the individual conductors 1/4” (6mm) from the end.
2. Cut a wall opening 14 9/16” (37cm) high by 11 1/4” (28.5cm) wide (see Figure 1). Allow a minimum of 2” (5cm) clearance around wall opening to accomodate heater frame. Depth of wall opening must be 3 1/4” (8.3cm) minimum, measured from nished wall surface.
3. Remove the screws securing heater assembly to the wall box and separate. Keep all screws for heater reassem­bly.
4. Remove rear knockout at top corner of wall box and insert 1/2 cable connector. Bring service leads through
connector and secure end of cable to the connector.
5. For safety, each wall heater is provided with a grounding screw located in the upper right corner of the wall box. Connect ground lead and tighten screw for good electri­cal connection.
6. Place wall box in wall opening so the welded side brack­ets rest on nished wall surface, and secure box with four #10 Philips head wood screws, 1 1/2” long (not pro­vided). Insert the wood screws through the inner set of ange holes at both top and bottom. Alternate holes are provided in sides of box for mounting to wood framing. (If wall box is installed prior to application of nished wall surface, set box to allow for wall thickness).
!
NOTE: When mounting wall box to hard wall surface,
predrill mounting and clearance holes to prevent splitting wall
surface.
7. Check nameplate on heater to make sure you are con-
necting to the proper voltage. Remove any packing ma­terial or debris from the heater assembly and wall box. Then connect service leads.
8. Place heater assembly into the wall box. Check fan to see that it turns freely, and service leads are clear of fan area. Secure heater assembly to the wall box with four sheet metal screws (provided).
9. Carefully position grille over heater assembly so that pro­truding switch and thermostat shaft do not bind against grille. Secure grille to heater assembly using two Phil­lips head sheet metal screws (provided). Push press-t thermostat knob on shaft.
10. Install the frame to the grille, securing its upper back edge behind the lip on the top of the wall box, and its lower edge with the single screw.
11. Energize heater circuit and test heater (see operating instructions).
Surface Installation
1. Allow 25” (63cm) of service cable for connecting the heater (see Fig. 2). Remove all but 2” (5cm) of outer jacket and strip individual conductors 1/4” (6mm) from end.
2. Mount surface box to the wall using the four provided #8 - 3/4” Philips head wood screws, inserted through mounting holes on the back side anges. (For hard wall surfaces, pre-drill mounting holes to prevent splitting wall surface.)
3. Install 1/2 cable connector in hole on bottom of surface boxnear right side. Feed service leads through and se­cure end of cable to the connector.
4. Remove the rear knockout on top of heater wall box near right side and insert bushing (provided). Feed service wires through bushing. Secure wall box to surface box with four sheet metal screws (provided with the surface box). Screws are inserted through the inside holes on the anges.
5. Proceed with steps 7 through 11 inclusive in recessed heater installation instructions.
Wiring
Two conductor non-metallic sheath cable with ground wire is
7204380100R07
Figure 1: RECESSED
GROUNDING SCREW
PHILLIPS HEAD
SCREW
3 1/4”MINIMUM
WALL OPENING
11 1/4”
12” CABLE
Figure 3
WALL STAT (OPTIONAL)
GRILL
FRAME
OVERTEMP LIGHT
120/208/240V
HEATER
THERMOSTAT
KNOB
ASSEMBLY
recommended for recessed installation of these heaters while two conductor, metallic sheath cable (BX) is recommended for surface installations. Use number 12 gauge wire for all models. Each heater should be on an individual, properly
fused circuit.
WARNING: Wiring procedures and connections should
be in accordance with the National Electric code (NEC) and
local codes.
1. When installing optional wall thermostat, unit mounted
thermostat must be set at it’s highest setting.
2. All external control equipment (shown with dashed lines) furnished by customer. Control wiring must be suitable for 600V.
3. Heater branch circuits shall have a carrying capacity of no less than 125% of maximum load served.
Figure 2: Surface
GROUNDING
SCREW
SHEET METAL
SCREW
SURFACE
WALL BOX
REMOVE THIS
KNOCKOUT
HEATER WALL BOX
25” SERVICE
LEADS
SERVICE CABLE
WALL BOX
WALL
OPENING
14 9/16”
REMOVE THIS
KNOCKOUT
ELECTRICAL
SERVICE
PER NAMEPLATE
SWITCH
GRID
FAN CONTROL
ALARM LIGHT
120/208/240V
THERMOSTAT
LIMIT CONTROL
THERMOSTAT
Operation
WARNING: This heater must be properly installed before
it is used.
These heaters are operated by an on/off switch and also a temperature control with a knob.
1. Turn the switch ON. Remember there is a fan delay.
2. Set thermostat by turning the knob to desired room com-
fort level (clockwise to increase heat output). Once you have determined the proper setting to provide the heat level you prefer, you need not touch the knob again.
3. Turn the switch OFF to turn off heater. To reuse, simply turn the switch ON - the temperature level you wish has been previously set.
!
NOTE: This heater is equipped with a fan delay switch which delays the fan operation until the heating grid has heated sufciently to assure the circulation of only warm air. This same switch permits the fan to operate after power to the grid has been shut off by thermostat action, thus utilizing all the heat remaining in the grid.
When the heater is shut down by turning the switch OFF, power to both fan motor and element is diconnected and the fan motor will not continue to operate.
WARNING:Should the OVERTEMP light come on,
disconnect power to the heater, turn the switch OFF or turn down the thermostat fully counterclockwise and call a licenced electrician. DO NOT USE HEATER UNTIL PROBLEM IS DETERMINED AND FIXED.
Tamper Proof Models
The ON/OFF switch and the temperature regulating thermo­stat are recessed so that the continuous grille front panel can be installed concealing both controls. The thermostat is op­erated by removing the front panel. The ON/OFF switch can be operated by inserting a slender non metallic rod between grill louvers and turning the switch ON or OFF.
www.dimplex.com2