Dimplex DXDHC10 Installation And Operating Instructions Manual

Page 1
1
Installation and Operating Instructions
SAFETY INFORMATION
1. Please read the operating instructions carefully before using your dehumidifier for the first time and keep them in a safe place.
2. Never immerse the appliance in water or other liquids.
3. Never operate the appliance if a cable or connector has been damaged, after appliance malfunction or if the appliance was dropped or otherwise damaged.
4. Please ask a professional service agent to repair the product. Improper repair may cause danger to users.
5. Never allow children to operate the appliance.
6. Disconnect the appliance from mains power whenever it is not in use, before relocating it, and before cleaning.
7. Operate the appliance only at the voltage specified on the rating label.
8. This appliance is designed for household purposes (not commercial) only.
9. DO NOT COVER. Never cover or obstruct in any way the outlet at the top of the dehumidifier or the air inlet slots at the rear of the dehumidifier.
10. To prevent spillage, empty the water tank before relocating the appliance.
11. Do not tip the appliance to any side as escaping water could damage the appliance. Only operate the product in a level upright position.
12. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
13. When the supply cord is damaged, it must be replaced by the manufacturer, or a professional service agent only.
14. Please keep the product from the wall or overhanging objects e.g. curtains at a minimum 50cm distance.
15. Unplug the appliance before cleaning.
humidifier 10L De
DXDHC10
model:
8/52647/0 Issue 0
Page 2
2
3
OPERATING INSTRUCTION
1. Power Switch
3. Right panel
4. Front panel
7. Water outlet tube
(continuous use)
8. Water tank
CONTROL PLATE DESCRIPTION
OPERATION INSTRUCTION
Starting the unit
Allow the unit to stand upright for 24hrs to let the compressor stabilize
before use.
1. Firstly, press the ON/OFF button to “OFF” position.
2. Plug in the dehumidifier.
3. Press the on/off button.
Turning off the unit
1. Press the ON/OFF button to the “OFF” position and the power supply is cut
off and the unit stops operating.
2. If the dehumidifier is not in use for a long time, please disconnect the power
cord plug from the supply outlet.
NOTES AND PRECAUTIONS
1. When the water in the tank is full an automatic float switch shuts down the product and the water level indicator light illuminates. Remove the water storage tank and empty its contents, carefully replace the empty water tank back in position, the unit will now automatically restart operating.
2. When the unit stops, you have to wait for 3 minutes before you can
restart the unit to protect the compressor from damage.
3. The operational temperature range for this unit is 5-32°C.
4. Other than on the case of note 1 above, where the dehumidifier does not start, the operational light does not illuminate or the dehumidifier intermittently stops for unknown reasons, please check the plug and power supply for poor connection. If the plug and power supply are in good condition, wait for 10 minutes and restart the unit (it can take about 10 minutes for the unit to reset). If the unit still does not start after 10 minutes, please contact your retailer or the manufacturer for repair.
5. When the dehumidifier is in operation, the running compressor will produce heat. This is normal and may potentially raise the room temperature.
6. When the product is defrosting, the defrost light will illuminate.
2. Air outlet
6. Air inlet
5. Handle / Left housing
Page 3
4
5
DRAINAGE INSTRUCTION
Switch off before carrying out any of these operations and leave for 3 minutes
before switching on again. The extracted water is collected by the water tank
(set up as supplied), or can be set up to drain continuously using a PVC hose
connected to a drain away outlet, which is lower than unit outlet (see details
below, not included).
USE OF WATER TANK:
When the water full indicator illuminates, the tank is full, and the compressor
and the fan will stop operation, please empty
the water tank:
Remove the water tank as per Fig 01. and
empty it.
Gently refit the water tank into the unit in its
original position.
CONTINUOUS DRAINAGE
1. If you want to use this function, please pull out the water tank and plug a
12.5mm internal diameter water pipe onto the “Water out tube” (See Fig.02).
Replace the water tank into the unit, the unit will now operate while
discharging the extracted water through
the free end of the fitted pipe, (note,
please ensure the free end is below the
outlet connection).
Please ensure drain away is lower than
the unit outlet.
Fig 02
Fig 01
Filter Removal
2. Take the air filter out upward by hands.
3. Every 2 weeks, remove the filter and clean it with warm water, below 40°C.
Allow it to dry naturally and then replace by reversing the removal instruction
above.
Care and Maintenance Instruction
1. To avoid the occurrence of vibration and noise the unit should not be
operated while located on any soft or uneven surface.
2. Never insert any foreign objects into the unit through its air inlet or outlet to
avoid hazard or unit failure.
3. During power off or when not in use for a long time, please disconnect the
product from the mains.
1. Slide the air inlet upward as shown below.
Page 4
4. For a better dehumidifying effect, the areas in front and rear of the unit
should be clear and free from any obstacles which will block the air flow of
the unit. Do not block any air inlet or outlet grilles – keep clear of hanging
drapes, curtains and furnishings – DO NOT COVER.
5. Every 2 weeks, remove the filter and clean it with warm water, below 40°C.
Allow it to dry naturally and then replace by reversing the removal
instruction above.
SPECIFICATIONS
Model
Specification
Power Supply
220-240V~50Hz
Power Input
250W
Running Current
1.2A
Net Weight
10.1Kg
Moisture Removal (30 RH80%)
10 liters/day
Dimension(W x D x H) mm
327Wx240Dx426H
Applicable temperature
5-32
Water Tank Capacity
1.8L
(CE) N 842/2006:
R134a is a kind of fluorinated greenhouse gas covered by
the Kyoto Protocol.
Its total global warming potential (GWP) is 1300
Recycling: For electrical products sold within the European Community. At the end of the electrical products useful life it should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice in your country.
6
7
DXDHC10
Page 5
After Sales Service:
Your product is guaranteed for 1 year fr
Your rights under this guarantee are additional to your statutory rights, which in
Please do not return any faulty product to us as this may
oviding you with a satisfactory service.
____________________________________________________________
CE This appliance complies with European Safety Standard EN60335-2-40, and
European Electromagnetic Capability (EMC) EN55014-1, EN55014-2,
EN61000-3-2 and EN61000-3-3. These cover the essential requirements of EEC
Directives 2006/95/EC and 2004/108/EC.
© GDC Group Ltd.
All rights reserved. Material contained in this publication may not be reproduced in whole or
in part without prior permission in writing of GDC Group Ltd.
8
om the date of purchase.
After sales information or assistance with this product can be found on our website: www.dimplex.com.uk/support.
turn are not affected by this guarantee.
result in loss or
damage and delay in pr
If after following these steps your product still does not operate you should return it to your point of purchase.
____________________________________________________________
Please retain your receipt as proof of purchase.
Loading...