Dimplex DXDH10IR, DXDH16BK Installation And Operating Instructions Manual

Page 1
1
This appliance complies with European Safety Standard EN 60335-2-40, EN 60335-1,and EN 62233.and European Electromagnetic
Capability(EMC)
EN 55014-1,EN 55014-2,EN 61000-3-2 and EN 61000-3-3.These cover the
essential requirements of EEC Directives
Installation and Operating Instructions
Model:
2006/95/EC and 2004/108/EC.
DXDH16BK
10L DehumidifierModel: DXDH10IR
Dehumidifier16L
8/51273/0 – Issue 3
SAFETY INFORMATION
1.
Please read the operating instructions carefully before using your dehumidifier for the first time and keep them in a safe place.
2.
Never immerse the appliance in water or other liquids.
3.
Never operate the appliance if a cable or connector has been damaged, after appliance malfunction or if the appliance was dropped or otherwise damaged.
4.
Please ask a professional service agent to repair the product. Improper repair may cause danger to users.
5.
Never allow children to operate the appliance.
6.
Disconnect the appliance from mains power whenever it is not in use, before relocating it, and before cleaning.
7.
Operate the appliance only at the voltage specified on the rating label.
8.
This appliance is designed for household purposes (not commercial)
9.
DO NOT COVER.
Never cover or obstruct in any way the outlet at the
top of the dehumidifier or the air inlet slots at the rear of the dehumidifier.
10.
To prevent spillage, empty the water tank before relocating the appliance.
11.
Do not tip the appliance to any side as escaping water could damage the appliance. Only operate the product in a level upright position.
12.
This appliance can be used by children aged from 8 years and above
only.
and persons with reduced physical,sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Page 2
2
3
13.
When the supply cord is damaged, it must be replaced by the manufacturer, or a professional service agent only.
14.
Please keep the product from the wall or overhanging objects e.g. curtains at minimum 50cm distance.
15.
Unplug the appliance before cleaning.
16.
When the unit stops, you have to wait for 3 minutes before you can restart the unit to protect the compressor from damage
OPERATING INSTRUCTION
1. Control panel
2. Air outlet
3. Handel
4. Front housing
5. Air Inlet / Back housing
6. Drain hole
7. Water tank
CONTROL PANEL DESCRIPTION
OPERATING INSTRUCTION
STARTING THE UNIT
1. Firstly, turn the humidity control switch to the “OFF” position.
2. Plug in the dehumidifier.
3. Turn on the humidity control switch (clockwise) and turn the same switch to the reading of the desired humidity (60% in general as shown on position“4”).
TURNING OFF THE UNIT
1. Turn the humidity control switch fully anticlockwise to the “OFF”
position and the power supply is cut off and the unit stops operating.
2. If the dehumidifier is not in use for a long time, please disconnect the
power cord plug from the supply outlet.
NOTES AND PRECAUTIONS
1.
The dehumidifier will not operate if the humidity setting is higher than the
ambient humidity.
2.
When the water tank is full an automatic float switch shuts down the product
and the tank full LED illuminates. Remove the water storage tank and empty
its contents, carefully replace the empty water tank back in position, the unit
will now automatically restart operating.
3.
The following table indicates the approximate relative humidity settings
against its related position number on the humidity control switch:
4.
The operational temperature range for this unit is 5-32.
CONTROL SWITCH
POSITION NO.
Cont.
8 7 30 6
4 2
APPROXIMATE
HUMIDITY SETTING
Continuous
running
20
40 60 80
Page 3
4
5
Fig 01
Fig 02
5.
Other than on the case of note 2 above, where the dehumidifier does not start, the operational light does not illuminate or the dehumidifier intermittently stops for unknown reasons, please check the plug and power supply for poor connection. If the plug and power supply are in good condition, wait for 10 minutes and restart the unit (it can take about 10 minutes for the unit to reset). If the unit still does not start after 10 minutes, please contact your retailer or the manufacturer for repair.
6.
When the dehumidifier is in operation, the running compressor will produce heat. This is normal and may potentially raise the room temperature.
7.
When the product is defrosting, related indicating light will illuminate.
DRAINAGE INSTRUCTION
Switch off before carrying out any of these operations and leave for 3 minutes
before switching on again. The extracted water is collected by the water tank (set up as supplied), or can be set up to drain continuously using a PVC hose (not included) connected to a water outlet tube , the drain point must be lower than the unit outlet (see details below).
USE OF WATER TANK:
When the tank full LED illuminates the tank is full, the compressor and the fan will stop operation, please empty the water tank. Remove the water tank:
Filter Removal
To remove the filter you must first remove
the water tank as instructed above.
The filter can then be removed from its slot
by gripping the filter handle and sliding it down and out of the back of the appliance as indicated below.
Every 2 weeks, remove the filter and clean
it with warm water, below 40°C. Allow it to dry naturally and then replace by reversing the removal instruction above
Care and Maintenance Instruction
1. To avoid the occurrence of vibration and noise the unit should not be operated while located on any soft or uneven surface.
2. Never insert any foreign objects into the unit through its air inlet or outlet to avoid hazard or unit failure.
3. During power off or when not in use for a long time, please disconnect the product from the mains.
Remove the water tank as per Fig 01 and empty it. Gently refit the water tank into the unit in its original position.
CONTINUOUS DRAINAGE
If you want to use this function, please pull out the water tank and plug a 9mm
internal diameter water pipe onto the “Water out
tube” (See Fig.02).Replace the water tank into the
unit, the unit will now operate while discharging the extracted water through the free end of the fitted pipe, Note, please ensure the free end is below the outlet connection.
Please ensure drain away is lower than the unit
outlet.
4. For a better dehumidifying effect, the areas in the front and rear of the
unit should be clear and free from any obstacles which will block the air
flow of the unit. Do not block any air inlet or outlet grilles – keep clear of
hanging drapes, curtains and furnishings- DO NOT COVER.
Page 4
6
7
SPECIFICATIONS
Model
Specification
Power Supply
Power Input(EN60335)
Rated Current
Net Weight
Moisture Removal (30 RH80%)
Dimension(W x D x H) mm
Applicable temperature
Water Tank Capacity
Contains fluorinated greenhouse gases Hermetically sealed system. Contains Refrigerant HFC134a 100% Global Warming Potential – 1430 Refrigerant Weight and CO2 equivalent weight by model as per below table
Model Refrigerant Weight CO2 Equivalent Weight
DXDH10IR 0.065Kg 0.093Kg tonnes
DXDH16BK
0.12Kg
DXDH10IR
220-240V~50Hz
250W
1.2A
10.6Kg
10 liters/day
365Wx220Dx500H
DXDH16BK
410W
2.1A
13.3Kg
16 liters/day
5-32
2.3L
0.172Kg tonnes
After Sales Service:
Your product is guaranteed for one year from the date of purchase. Within this period, we undertake to repair or exchange this product free of charge provided it has been installed and operated in accordance with these instructions.
Your rights under this guarantee are additional to your statutory rights, which in turn are not affected by this guarantee. Should you require after sales information or assistance with this product please go to www.glendimplexireland.com
where you can click
on the ‘Customer Care’ tab or ring 01 842 4833.
Please retain your receipt as proof of purchase.
This appliance complies with European Safety Standard EN 60335-2-40,
EN 60335-1,and EN 62233.and European Electromagnetic Capability(EMC) EN 55014-1,EN 55014-2,EN 61000-3-2 and EN 61000-3-3.These cover the
essential requirements of EEC Directives 2006/95/EC and 2004/108/EC.
Glen Dimplex Ireland uc
Customer Service : 01 842 4833 Airport Road Fax: 01 842 4705 Cloghran Website:
www.glendimplexireland.com
Co. Dublin
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible hazards to the environment or human health from uncontrolled waste disposal, please recycle it to prove the sustainable reuse of material resources. Please ask return and collection systems or contact the retailer where the product was purchased to return your used device, they can recycle products safely.
Loading...