Dimplex DCB05C, DCB07, DCB09, DCB14 User Manual

Window/Wall Box Air Conditioner
Cooling Only: DCB05C, DCB07C & DCB09C Reverse Cycle: DCB07, DCB09 & DCB14
INSTRUCTION MANUAL
PLEASE READ THE INSTRUCTION MANUAL CAREFULLY BEFORE USING THE UNIT.
www.dimplex.com.au
Table of Contents
Page
Introduction
Operating Instructions
Electrical Specifications
Installation Instructions
Care and Maintenance
Trouble Shooting Guide
2
4
5
6
9
10
- 1 -
Introduction
Front Cover
Air inlet grille (Indoor)
Cabinet
Air outlet grille (Indoor)
Air inlet grille (Outdoor)
Vent Lever
Control Panel
Air filter
Fig.1-1
DCB05C/DCB07C/DCB09C
SLE EP
DCB07/DCB09 DCB14
- 2 -
11
Compressor running
Operating Instructions
Remote controller
The remote controller transmits signals to the system.
No.
1
2
3
4
5
6
8
9
Button
(TEMP UP)
(TEMP DN)
ON/OFF
FAN
TIMER
SLEEP
MODE
SWING
Function
Increase the temperature or time by 1 unit
Decrease the temperature or time by 1 unit
To switch the conditioner on and off.
To select the fan speed of auto/low/mid/high
To set automatic switching-on/off
To activate the function SLEEP
To select the mode of operation
To activate or deactivate of the movement of the DEFLECTORS .
SLEEP
TIMER ON
TMIER OFF
FEEL COOL DRY FAN
SLEEP
TIMER
ON/OFF
MODE
Remote Controller
The outlooking and some function of remote control may vary according to the model.
AUTO HIGH MID LOW SWING
FAN
SWING
The shape and position of buttons and indicators may vary according to the model, but their function is the same.
The unit confirms the correct reception of each press button with a beep.
- 4 -
CAUTION
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
DCB05C/DCB07C/DCB09C
DCB07/
RECEPTACLE AND FUSE TYPES
DCB05C DCB07C
RATED VOLTS
AMPS
RATED VOLTS
AMPS
250V
7.1A
RECEPTACLE AND FUSE TYPES
DCB07
DCB09C
250V
7.1A
DCB09 DCB14
250V 250V250V
7.1A7.1A 8.5A
250V
7.1A
Installation instructions
REMOVE ALL THE SHIPPING PARTS BEFORE INSTALLATION
LOCATION
Select a location that can support the weight of the air conditioner and one that will not cause increased operation noise and vibration. Direct sunlight is unfavorable for efficient cooling. Select a place where there is no obstacles near the air inlet and outlet.
Less than 210
More than 55
wall thickness is less than 210
5-10mm
Make rear side lower so that waterwill drain out smoothy.
Less
210
than
Scrape
lf the wall thickness is more than 210 scrape the wall as shown above.
more
than 400
more
than 500
45
more
than 400
less
than 210
- 6 -
Installation instructions
CAUTION
Do not install air conditioner in the place where flammable gas leaks are a possibility.
The minimum clearance from the appliance to combustible surfaces is 100mm; (Only for electric heating)
The range of external static pressures at which the appliance was tested is 0-5Pa
OPERATION
Check the capacity of wiring and power outlet. The power outlet should be used exclusively for the air conditioner. Do not use it with other appliances.
Ground the air conditioner to prevent danger of electric shock. Connect the air conditioner with power source securely. Use a fuse as below.
CAUTION
Before installation,turn off the operation switch and disconnect the power cord.
This appliance is not intended for use by persons(including children) with reduced physical, sensory or mental capabilities,or lack of knowledge, unless they have been given supervision or instruction concernĀ­ing use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
The appliance is fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under over voltage category III conditions, and these means must be incorporated in the fixed wiring in accordance with the wiring rules.
- 7 -
experience and
Installation instructions
1) Remove the front panel. (Fig.5) Remove the air filter. (Fig.6) Remove screw at the botton of the front panel. (Fig.7) Open the panel cover.
2) Remove the screws fix the chassis-fixing board and cabinet. some Models have two more screws on the back of the cabinet. (Fig.8)
3)
Grasp the handle on the front of the chassis and carefully
slide the air conditioner unit out of the cabinet. (Fig.9) lnstall the drain tube connection into the hole provided
4)
at the rear of the air conditioner chassis.(Fig.11) To meet different requirements of different type of air conditioner, there are two kinds of methods for your choice to treat the condensed water. You can choose back
drainage or bottom drainage. Bottom drainage way: the drain tray is fixed in position through four pcs of screws and use the flare nut to block
the back drainage hole.(Fig.15) Back drainage way drainage hole and use water outlet pipe to connect the back drainage hole pay attention to increase the sealing ring to prevent water leakage.(Fig.16)
lnstall the air conditioner cabinet on the installation shelf
5)
(not included) with screws.(Fig.10)
6) Carefully slide the unit back into the cabinet.(Fig .12)
7) Reinstall the retaining bracket,front panel and mounting
screws.(Fig.8,7,13)
8) Reinstall the air filter.(Fig.14)
using the flare nut to block the bottom
Screw
Fig.5
Fig.6
Fig.7
Fig.8
Fig.9
Wall
Cabinet
Installation shelf
Fig.10
Fig.14
Fig.11
drain tray
screw
- 8 -
Fig.12
Fig.15
falre nut
falre nut
sealing ring
water outlet pipe
Fig.13
Fig.16
Care and Maintenance
AIR FILTER
The air filter should be washed at least once a month. lf the air filter remains full of dust, the air flow will decrease and the cooling capacity will be reduced. The filter is behind the cover and to be pulled out from right hand side. Wash the air filter with water and detergent. Rinse with clean water and dry completely before reinstalling.
Fig.15
CAUTION
Do not use hot water above 40 C f or w ashing t he a ir f ilter. Let the filter dry thoroughly in the shade before reinstalling. Do not expose it directly on the sun. Do not operate the air conditioner with the filter removed. T1 condition: The ambient temperature for cooling: 18~43 ;
The ambient temperature for heating: -5~20 .
T3 : The ambient temperature for cooling: 25~52 ;condition
The ambient temperature for heating: -5~20 .
AIR CLEANING FILTER
The air cleaning filter is attached to the air filter. Wash the air cleaning filter as well when wash air filter.
FRONT COVER,ETC
The front cover will accumulate dirt and dust. To clean it, wipe it with a soft dry cloth. When it is excessively dirty, wipe it with a soft cloth dampened with warm water or mild soap, then wipe it again thoroughly with a soft dry cloth.
Fig.16
Hot Water
Benzine,acid,etc.
- 9 -
Troubleshooting Guide
Never use hot water above 50 ,benzine,gasoline,acid,thinner or brush to wipe off dirt because they will damage the plastic surface and the coating.
LONG OFF PERIOD MAINTENANCE
Operate the fan alone ("LOW FAN"or"HIGH FAN") for half a day to dry out the inside of the unit. Turn off power and remove plug from wall socket. After a long off period and going to use the air conditioner again , clean the CONDENSER(at the rear)and EVAPORATOR (at the front)fins by using a soft brush or vacuum cleaner.
CAUTION
Be careful not to damage the fins during the cleaning.
BEFORE ASKING FOR SERVICE
Check the following points before requesting for repairs or service. lf the malfunction persists,pelase contact our customer service.
Faults Cause
Does not operate
Does not cool effectively
ls the power off? ls the fuse blown? ls the voltage extremely high or low? ls the operation dial set to"off"?
ls the air filter remain full of dust or dirt?
See air filter instructions on page 9.
Is the sunlight fall directly on the unit?
ls the air flow on the rear side obstructed? Leave a space of 500mm behind the rear side of the air condition?
The doors or windows may be opened widely or there are other sources of heat in the room?
The temperature dial may not set to the colder position. Turn the dial further clockwise.
ls the ventilation damper opened?