Dimplex CS2307, CS4416, CS3311 User Manual

CS3311 Pictured
Service Manual
Compact Stove
Model Numbers:
CS3311 CS4416 CS2307
Dimplex North America Limited
1367 Industrial Road Cambridge ON Canada N1R 7G8 1-888-346-7539 www.dimplex.com
In keeping with our policy of continuous product development, we reserve the right to make changes without notice.
REV PCN DATE
01 11563 Aug 10, 09
02 11993 April 12, 10
03 Sept 4, 12
7400100000R03
Table of Contents
Operation .......................................................................3
Exploded Parts Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Replacement Parts List ............................................................4
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Light Bulb Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Partially Reective Glass Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Switch Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Flicker Motor/Flicker Rod Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Remote Control Receiver Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Heater Assembly/Cutout Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Thermostat Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Power Cord Replacement .........................................................10
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2

Operation

Electric Stove Manual Control
unplug the unit and call Dimplex North America Limited at 1-888-346-7539 for technical support.
The manual controls for the stove are located in the upper left hand corner on the rear of the stove (Figure 1).
Figure 1
A
B
A. 3 Position Switch
The switch has two (2) ON positions marked with “Manual”.
The “Manual” position is for manual operation. In this position the built-in remote control is by-passed.
C
and
Remote Operation
The stove is supplied with an integrated ON/OFF remote control.
!
NOTE: Ensure that the stove’s 3 Position Switch is set to
the remote Control setting (right position - see Figure 1A).
To operate, push the ON button to turn stove on, push the OFF button to turn the stove off.
Battery Replacement (Figure 2)
To replace the battery:
1. Slide battery cover open on the remote control.
2. Correctly install one 12 Volt (A23) battery in the battery holder.
3. Close the battery cover.
Figure 2
The
position is for operating the unit with the provided
remote control. When in the ON and OFF buttons of the remote control.
When the switch is in the center position the unit is off.
B. Heater ON/OFF Switch
The Heater ON/OFF Switch supplies power to the heater fan and the heater element. When the switch is in the ON position the heater operates if the thermostat calls for heat.
C. Heater Thermostat Control
To adjust the temperature to your individual requirements, turn the thermostat control clockwise all the way to turn on the heater. When the room reaches the desired temperature, turn the thermostat knob counter clockwise until you hear a click. Leave in this position to maintain the room temperature at this setting. For additional heat, turn clockwise until you hear the click again and the heater will turn on.
!
NOTE: When the heater is switched ON, the heater fan
will operate. The heater element may or may not be on, depending on the thermostat control setting (see “Heater Thermostat Control”).
position the unit is operated with
On Button
Battery
Off Button
Battery Cover
Remote Initialization
Follow these steps to initialize or if necessary, re-initialize:
1. Disconnect power to the stove.
2. Ensure 3 Position Switch is in the Remote position (far right).
3. Restore power to stove.
4. Within 10 seconds of restoring power to stove, press the ON button of the Remote Control.
Resetting The Temperature Cutoff Switch
Should the heater overheat, an automatic cut out will turn the heater off and it will not come back on without being reset. It can be reset by switching the 3 Position Switch to OFF and
waiting ve (5) minutes before switching the unit back on.
CAUTION: If you need to continuously reset the heater,
!
NOTE: If you do not press the ON button of the remote
within 10 seconds, the process will need to be started again.
3

Exploded Parts Diagram

CS3311 Design
CS2307 Design
14
14
8
13
17
5
10
12
7
11
6
14
9
CS4416 Design

Replacement Parts List

CS3311
Part Number 6901050100
CS2307
Part Number 6901051300 Replacement Part:
1. Log Set Assembly . . . . . . . . . . . . . . . . .0438500400RP
2. Flicker Motor . . . . . . . . . . . . . . . . . . . . .2000210100RP
3. Heater Assembly . . . . . . . . . . . . . . . . .2200491000RP
4. Cutout . . . . . . . . . . . . . . . . . . . . . . . . . .2300270100RP
5. 3 Position Switch . . . . . . . . . . . . . . . . .2800071100RP
6. Power Cord . . . . . . . . . . . . . . . . . . . . .4100090202RP
7. Heater ON/OFF Switch . . . . . . . . . . . . .2800070200RP
8. Partially Reective Glass. . . . . . . . . . . .5900640100RP
9. Remote Control ...................3000370800RP
15
16
3
1
4
CS4416
Part Number 6901050600
10. Remote Control Receiver ...........3000380200RP
11. Flicker Rod . . . . . . . . . . . . . . . . . . . . . .5900081100RP
12. Lamp holder. . . . . . . . . . . . . . . . . . . . . .4200090100RP
13. Thermostat Knob. . . . . . . . . . . . . . . . . .8800000300RP
14. Polished Door Knob (CS3311) . . . . . . .8800340100RP
Door Handle (CS4416, CS2307). . . . . .8800450100RP
15. Capacitor . . . . . . . . . . . . . . . . . . . . . . . .2300030100RP
16. Terminal Block . . . . . . . . . . . . . . . . . . . .4000070100RP
17. Thermostat . . . . . . . . . . . . . . . . . . . . .2300150100RP*
2
4
Loading...
+ 9 hidden pages