Dimplex ADG20 User Manual

Installation and Operating Instructions
Dimplex Adagio Fire Model : ADG20
Dimensions
(millimetres)
635
IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULL Y AND RET AINED FOR FUTURE REFERENCE
Important Safety Advice:
When using electrical appliances, Basic precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons, including the following:
••
If the appliance is damaged, check with the
••
supplier before installation and operation.
••
Do not use outdoors.
••
••
Do not use in the immediate surroundings of a
••
bath, shower or swimming pool.
••
Do not locate the heater immediately below a fixed
••
socket outlet or connection box.
••
Do not cover the heater. Do not place material or
••
garments on the heater, or obstruct the air circulation around the heater, for instance by curtains or furniture, as this could cause overheating and a fire risk.
••
This appliance is not intended for use by children
••
or other persons without assistance or supervision if their physical, sensory or mental capabilities prevent them from using it safely. Children should be supervised to ensure that they do not play with the appliance.
••
Do not use this heater in series with a thermal
••
control, a program controller, a timer or any other device that switches on the heat automatically, since a fire risk exists when the heater is accidentally covered or displaced.
••
Ensure that furniture, curtains or other
••
combustible material are positioned no closer than 1 metre from the heater.
••
In the event of a fault unplug the heater.
••
••
Unplug the heater when not required for long
••
periods.
••
Although this heater complies with safety
••
standards, we do not recommend its use on deep pile carpets or on long hair type of rugs.
••
The appliance must be positioned so that the plug
••
is accessible.
••
If the supply cord is damaged it must be replaced
••
by the manufacturer or service agent or a similarly qualified person in order to avoid a hazard.
516
08/19310/0 Issue 0
245
115
Fig. 1
General
Unpack the heater carefully and retain the packaging for possible future use, in the event of moving or returning the fire to your supplier. Loose coals and pebbles are packed separately within the carton. When the heater is assembled the coals or pebbles are placed on top of the fuel bed. ‘The coals may be removed and pebbles added in their place up to a maximum weight of 6KG.
The heater is designed for use inset into a 407mm (16") or 457mm (18") wide by 559mm (22") high fireplace opening see also section “Installation in a fire place opening”.
A 2kw fan heater discreetly positioned in the canopy of the fire provides heating in cold weather. Switching allows half or full heat.
Before connecting the heater check that the supply voltage is the same as that stated on the heater.
Please note: Used in an environment where background noise is very low, it may be possible to hear a sound which is related to the operation of the flame effect. This is normal and should not be a cause for concern.
Electrical
WARNING – THIS APPLIANCE MUST BE EARTHED
This heater must be used on an AC ~ supply only and the voltage marked on the heater must correspond to the supply voltage. Before switching on, please read the safety warnings and operating instructions. For your convenience, the heater is fitted with a rewireable plug incorporating a 13 amp fuse. In the event of replacing the fuse in the plug supplied, a 13 amp fuse approved by ASTA to BS1362 must be used.
Installation in a Fireplace Opening
Safety cut-out
At the rear of the fire, two adjustable supports are provided for levelling the fire where the base of the fireplace opening is raised above the level of the hearth.
Adjust by removing the two screws holding each bracket in position, then refit the bracket and the two screws in the required position.
Operation
The unique flame effect may be enjoyed whether or not the heating elements are in operation.
Controls
The heater controls are located on the left hand side of the canopy heat outlet.
Three switches provide a choice of heat settings. A switch is in the ON position when the red indicator mark on
the switch is visible.
Switch 1
Switch 2
Switch 3
Fig. 2
For your safety, this appliance has been fitted with a thermal cut-out. In the event that the product overheats, the cut-out switches the heat off automatically.
To bring the heat back into operation, remove the cause of the overheating, then unplug or turn off the electrical supply to the heater for up to 10 minutes.
When the heater has cooled sufficiently, re-connect and switch on the heater.
Cleaning
Before commencing cleaning, unplug the heater and allow it to cool.
The surfaces of the heater should be given an occasional wipe over with a dry soft cloth.
Do not use detergents, abrasive cleaning powder or polish on the metal body of the heater.
The glass screen should be cleaned carefully with a chamois leather. DO NOT use proprietary cleaners.
To remove any accumulation of dust or fluff the soft brush attachment of a vacuum cleaner should occasionally be used to clean the outlet grille of the fan heater located under the canopy.
To clean the fuel effect, remove the coal/pebbles and wash in warm water. The plastic tray should be wiped clean with a damp cloth. When dry replace the coal/pebbles and arrange for best effect.
After Sales Service
Switch 1 - Controls the electricity supply to the heater
and the flame effect. Note: This switch must be in the ON position for the heater to operate.
Switch 2 - Provides 1kw heat output. Switch 3 - Provides 2kw heat output with switch 2.
Maintenance
WARNING – BEFORE UNDERT AKING ANY MAINTENANCE OR CLEANING , REMOVE PLUG OR DISCONNECT FROM THE ELECTRICITY SUPPL Y .
Lamp Replacement
There are two lamps located beneath the fuel effect. To gain access to the lamps, remove the coal/pebbles and place in a container, lift out the plastic fuel effect to reveal the lamps. Replace the defective lamp with a 240V - 60W E14 SES clear candle lamp. Replace plastic fuel effect and coal/pebbles.
Your product is guaranteed for one year from the date of purchase.
Within this period, we undertake to repair or exchange this product free of charge (excluding lamps & subject to availability) provided it has been installed and operated in accordance with these instructions.
Your rights under this guarantee are additional to your statutory rights, which in turn are not affected by this guarantee.
Should you require after sales service you should contact our customer services help desk on 0870 727 0101. It would assist us if you can quote the model number, series, date of purchase, and nature of the fault at the time of your call. The customer services help desk will also be able to advise you should you need to purchase any spares.
Please do not return a faulty product to us in the first instance as this may result in loss or damage and delay in providing you with a satisfactory service.
Please retain your receipt as proof of purchase.
Glen Dimplex UK Limited Millbrook House Grange Drive Hedge End Southampton Hampshire. SO30 2DF
[c] Glen Dimplex UK Limited All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex UK Limited.
The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014, EN60555-2 and EN60555-3 which cover the essential requirements of EEC Directives 73/23 and 89/336
UK customer help line (8.00AM – 6.00PM Mon-Fri; 8.30AM-1.00PM Sat) Customer Services: Tel. 0870 7270101
Fax. 0870 7270102 e-mail customer.services@glendimplex.com
Republic of Ireland Tel. 01 8424833
Loading...