Installation and Operating Instructions
Dimplex Air Curtains
Models : AC3N, AC45N, AC6N & AC3RN
Dimensions
(millimetres)
Hole
Bracket
centres
Model(s) Watt
AC3N 3.0kw
AC45N 4.5kw
AC6N 6.0kw
AC3RN 3.0kw
(Remote control)
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.
A
605
605
905
605
B
424
424
721
424
IMPORTANT SAFETY ADVICE
DO NOT COVER OR OBSTRUCT the air inlet or outlet
grille.
ENSURE THE APPLIANCE IS EARTHED.
Do not use this heater in areas where excessive dust
exists.
This heater must not be located immediately above
or below a fixed socket outlet or connection box.
Always disconnect supply before working on the
product.
This product should be mounted safely to solid wall
or ceiling surfaces only.
Ensure the supply cables are of adequate current carrying capacity and are protected by a suitable fuse.
If the appliance is mounted in a toilet or washroom,
the appliance should be mounted such that no part
of it can be touched by a person using a fixed bath or
shower.
If the appliance is mounted in a toilet or washroom
an isolating switch must be provided outside the
washroom adjacent to the entrance door.
Electrical
The installation of this appliance should be carried out by a
competent electrician and be in accordance with the current
IEE wiring regulations.
Fixing Positions
This appliance may be either wall-mounted or fixed to a ceiling - see Fig. 2 for various fixing positions and ‘Installation’ for
details on fixing.
ceiling
length
C
492
492
756
492
Ceiling mounting
Front view Side views
08/18848/0 Issue 0
’C’
’B’
214
’A’ 135
cable/conduit
entry
50
ceiling mtd. wall mtd.
45
155
Installation
Using the wall mounting bracket as a guide (see Fig. 3) mark
off the hole positions on the wall or ceiling - a minimum height
of 1.8metres is required from floor to bracket. Fix the bracket
in position by following steps as described under the heading
‘Wall or Ceiling Mounting’.
Wall or Ceiling Mounting
Solid brick or concrete block walls must be drilled and plugged
(using a spirit level as a guide ensure bracket is level) with
rawlplug No. 8 size fibre inserts. The plug must be located in
the solid part of the wall, not just in the plaster layer.
For panelled internal walls or ceilings, it is best to locate the
studding, position the heater fixing bracket accordingly and
use No. 8 size wood screws. If it is not possible to locate the
studding, use type M4 Rawlplug inserts, making the 10mm
holes with a drill rather than a bradawl or a screwdriver.
Locate the heater
on the mounting
bracket ensuring
that the pozi-head
wall
mounting
bracket
see Fig. 4
Fig. 3
It is important that the serrated metal washer is located between the heater holding bracket and the wall mounting
bracket. Adjust heater to the required angle then firmly tighten
the fixing screws inside the endcap using a cross-head screwdriver as shown in Fig. 4.
wall
mounting
access hole for
screwdriver
serrated washer
bracket
screws are fully engaged in the slots
of the bracket.
holding bracket
fixing screw
200
Fig. 1
Wall mounting
Fig. 2
Heaters may be mounted end to end for wide doorways.
Detail view of Wall fixing bracket arrangement
Fig. 4

Release the screws at either end of the air-outlet grille (see
Fig. 5) to gain access to the terminals for connection of the
supply cable - see Fig. 6.
M
Element Element
CUT-OUT CUT-OUT
Mains
Cable
’A’
’B’
screw
cable
Cable
clamp
see Fig. 6
outlet
screw
grille
Fig. 5
Insert the mains cable down
the outside of the back panel
(not on inside) and through
the rear entry cable clamp
and make connection as
shown in Fig. 6 see also Fig.
7 for detailed views of cable
clamps.
Fig. 6Detail view of cable entry
Fig. 7a
Cable clamp detail for
AC3N & AC3RN models
Element
CUT-OUT
Isolater
Switch
Isolator
Switch
Heat
Switches
Fig. 8
Terminal
Block
ENL
E
AC3N
Wiring
Diagram
M
Element
CUT-OUT
Heat
Switches
Terminal
Block
E
N
L
E
Fig. 9
AC45N
Wiring
Diagram
cable
Cable clamp detail for
AC45N & AC6N models
Fig. 7b
’A’
’B’
Note : Part ‘A’ of cable
clamp is flipped over to
receive the larger cable
Connection to fixed wiring should be made through an adjacent minimum 20 amp double-pole switch for AC3N, AC3RN
& AC45N models.
Connection to fixed wiring should be made through an adjacent minimum 30 amp double-pole switch for AC6N model
with a minimum separation of 3mm in each pole.
Re-secure the outlet grille.
Ensure that the air-curtain is securely fastened and that the
supply cable is firmly clamped before operating the appliance.
Element
CUT-OUT
Isolator
Switch
Element
Isolator
Switch
CUT-OUT
M
ENL
Terminal
Block
Element
Heat
Switches
CUT-OUT
E
E
Fig. 10
AC6N
Wiring
Diagram
M
Element
CUT-OUT
Heat
Switches
OUT IN
N
L
LNE
Terminal
Block
E
Fig. 11
AC3RN
Wiring
Diagram