Dimplex AC3N, AC6N, AC3RN, AC45N Installation Instructions

Installation and Operating Instructions
Dimplex Air Curtains Models : AC3N, AC45N, AC6N & AC3RN
Dimensions
(millimetres)
Hole
Bracket
centres
Model(s) Watt
AC3N 3.0kw
AC45N 4.5kw
AC6N 6.0kw
AC3RN 3.0kw
(Remote control)
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.
A
605
605
905
605
B
424
424
721
424
IMPORTANT SAFETY ADVICE
DO NOT COVER OR OBSTRUCT the air inlet or outlet grille.
ENSURE THE APPLIANCE IS EARTHED.
Do not use this heater in areas where excessive dust exists.
This heater must not be located immediately above or below a fixed socket outlet or connection box.
Always disconnect supply before working on the product.
This product should be mounted safely to solid wall or ceiling surfaces only.
Ensure the supply cables are of adequate current car­rying capacity and are protected by a suitable fuse.
If the appliance is mounted in a toilet or washroom, the appliance should be mounted such that no part of it can be touched by a person using a fixed bath or shower.
If the appliance is mounted in a toilet or washroom an isolating switch must be provided outside the washroom adjacent to the entrance door.
Electrical
The installation of this appliance should be carried out by a competent electrician and be in accordance with the current IEE wiring regulations.
Fixing Positions
This appliance may be either wall-mounted or fixed to a ceil­ing - see Fig. 2 for various fixing positions and ‘Installation’ for details on fixing.
ceiling
length
C
492
492
756
492
Ceiling mounting
Front view Side views
08/18848/0 Issue 0
’C’
’B’
’A’ 135
cable/conduit entry
50
ceiling mtd. wall mtd.
45
Installation
Using the wall mounting bracket as a guide (see Fig. 3) mark off the hole positions on the wall or ceiling - a minimum height of 1.8metres is required from floor to bracket. Fix the bracket in position by following steps as described under the heading ‘Wall or Ceiling Mounting’.
Wall or Ceiling Mounting
Solid brick or concrete block walls must be drilled and plugged (using a spirit level as a guide ensure bracket is level) with rawlplug No. 8 size fibre inserts. The plug must be located in the solid part of the wall, not just in the plaster layer.
For panelled internal walls or ceilings, it is best to locate the studding, position the heater fixing bracket accordingly and use No. 8 size wood screws. If it is not possible to locate the studding, use type M4 Rawlplug inserts, making the 10mm holes with a drill rather than a bradawl or a screwdriver.
Locate the heater on the mounting bracket ensuring that the pozi-head
wall mounting bracket
see Fig. 4
Fig. 3
It is important that the serrated metal washer is located be­tween the heater holding bracket and the wall mounting bracket. Adjust heater to the required angle then firmly tighten the fixing screws inside the endcap using a cross-head screw­driver as shown in Fig. 4.
wall mounting
access hole for screwdriver
serrated washer
bracket
screws are fully en­gaged in the slots of the bracket.
holding bracket
fixing screw
200
Fig. 1
Wall mounting
Fig. 2
Heaters may be mounted end to end for wide doorways.
Detail view of Wall fixing bracket arrangement
Fig. 4
Release the screws at either end of the air-outlet grille (see Fig. 5) to gain access to the terminals for connection of the supply cable - see Fig. 6.
M
Element Element
CUT-OUT CUT-OUT
Mains Cable
’A’
’B’
screw
cable
Cable clamp
see Fig. 6
outlet
screw
grille
Fig. 5
Insert the mains cable down the outside of the back panel (not on inside) and through the rear entry cable clamp and make connection as shown in Fig. 6 see also Fig. 7 for detailed views of cable clamps.
Fig. 6­Detail view of cable entry
Fig. 7a Cable clamp detail for
AC3N & AC3RN models
Element
CUT-OUT
Isolater Switch
Isolator Switch
Heat Switches
Fig. 8
Terminal Block
ENL
E
AC3N Wiring Diagram
M
Element
CUT-OUT
Heat Switches
Terminal Block
E
N
L
E
Fig. 9
AC45N Wiring Diagram
cable
Cable clamp detail for AC45N & AC6N models
Fig. 7b
’A’
’B’
Note : Part ‘A’ of cable clamp is flipped over to receive the larger cable
Connection to fixed wiring should be made through an adja­cent minimum 20 amp double-pole switch for AC3N, AC3RN & AC45N models.
Connection to fixed wiring should be made through an adja­cent minimum 30 amp double-pole switch for AC6N model with a minimum separation of 3mm in each pole.
Re-secure the outlet grille.
Ensure that the air-curtain is securely fastened and that the supply cable is firmly clamped before operating the appliance.
Element
CUT-OUT
Isolator Switch
Element
Isolator Switch
CUT-OUT
M
ENL
Terminal Block
Element
Heat Switches
CUT-OUT
E
E
Fig. 10
AC6N Wiring Diagram
M
Element
CUT-OUT
Heat Switches
OUT IN
N
L
LNE
Terminal Block
E
Fig. 11
AC3RN Wiring Diagram