Dimplex 7206620100 User Manual

OPTIONAL
REMOTE
CONTROL
INSTALLATION
DEPRESS MOUNTING
PLUG CONNECTOR
MANUAL CONTROL
FIGURE 4
FIGURE 5
TABS
MANUAL CONTROL REMOVAL
1. Open steel curtain (remove glass doors if applicable).
2. Remove two screws on log grate and remove log grate (FIGURE 4).
3. Pull front edge of plastic ember bed grate up and forward until rear tab releases from the ledge located at the bottom of the mirror. (FIGURE 5) Note: Log set fits tightly into firebox, some force may be necessary to remove. (FIGURE 5)
4. Locate and remove the two screws on the manual control bracket. Remove the bracket. (FIGURE 6)
5. Locate and depress the mounting tabs on the plug connector and remove the manual control bracket. (FIGURE 6)
REMOTE CONTROL INSTALLATION
1. Locate and insert the plug connector on the
remote control bracket into plug connector on the fireplace. FIGURE 7)
2. Locate and install the two screws on the
remote control bracket.
3. Replace the log by inserting front edge and
pushing the back down until rear tab snaps under back ledge (FIGURE 5) and the logs are resting against mirror.
4. Replace log grate using two screws
previously removed.
PLUG CONNECTOR
MANUAL CONTROL
FIGURE 6
REMOTE CONTROL
FIGURE 7
OPERATION
FIGURE 1
REMOTE CONTROL
The remote control has a range of approximately 50ft. (15.25m), it does not have to be pointed at the fireplace and can pass through most obstacles (including walls). It is supplied with one of 2187 independent frequencies to prevent interference with other units. The frequency designation is indicated on the back of the transmitter (FIGURE 1).
A. Remote Control Initialization
This procedure is required every time there is a loss of power to the remote control in the fireplace (i.e. power failure, breaker tripped, main power switch is turned off)
1. Ensure that power is supplied through main service panel.
2. Access the manual controls, (remove glass doors if applicable) pull the right hand steel curtain to the outside of the unit. (FIGURE
2)
3. Locate manual controls refer to FIGURE 3.
4. Activate main power switch, red indicator light 1 will flash.
5. Press and hold the on switch marked -- for five seconds. The second red indictor light will flash.
6. Press ON button located on the remote control transmitter (FIGURE 1). This will synchronize the remote control transmitter and receiver.
B. Remote Control Usage
The remote control operates the fireplace levels sequentially. The level is increased every time the ON button on the transmitter is pressed. The fireplace can be turned off at any point by pressing the OFF button on the
FIGURE 2
Level 1: The flame effect is turned on and the first red indicator light is activated. Level 2: The flame effect remains on, the heater is activated to the low heat
setting (flame effect and purifier only on PurifireTM equipped units), and the first and second red indicator lights are activated. Level 3: The flame effect remains on, the heater is set to the high heat setting, and all three red indicator lights are activated.
remote control transmitter.
MANUAL CONTROLS
A. ON SWITCH
The fireplace can also be controlled in a similar manner to the remote control with switches located on the fireplace (FIGURE3).
A. On Switch
Operates fireplace in the same manner as the remote control transmitter. Pressing this button has the same effect as the ON button on the remote control. Pressing once to the activates Level 1, twice activates Level 2, three times activates Level 3.
B. Off Switch
Pressing this button has the same effect as the OFF button on the remote control. Pressing once to shut the unit off.
LEVEL 1 INDICATOR
LEVEL 2 INDICATOR
FIGURE 3
B. OFF SWITCH
LEVEL 3 INDICATOR
Loading...