Dimplex 403TS, 403TSF, 403TSFTie, 403TSTi Installation And Operating Instructions Manual

attention has to be given where children and vulnerable people are present. If the mains lead is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualied person in order to avoid a
hazard.
Electrical connection
The use of an extension lead or multi-plug adaptor is not advised when connecting this product to the mains. Connection through these devices
could lead to a risk of overloading, overheating and even re at the extension
lead or adaptor due to inadequate connection quality. This heater must be used on an ~ supply only and the voltage marked on
the heater must correspond to the supply voltage. This heater is tted with
a rewireable plug incorporating a 13 amp fuse. In the event of replacing the fuse in the plug supplied, a 13 amp fuse approved by ASTA to BS 1362 must be used. If any other type of plug is used, a 15 amp fuse must be
tted in the plug, the adaptor, or at the distribution board.
IMPORTANT : If the plug is not suitable for your socket, the 13 amp plug should be removed. Before wiring the appropriate plug, please note that the wires in this mains lead are coloured in accordance with the following code : GREEN AND YELLOW: EARTH
BLUE : NEUTRAL BROWN : LIVE
Connect the GREEN AND YELLOW wire to the terminal marked ‘E’ or by the earth symbol
, or coloured GREEN or GREEN AND YELLOW. Connect the BROWN wire to the terminal marked ‘L’ or coloured RED. Connect the BLUE wire to the terminal marked ‘N’ or coloured BLACK.
Using the heater
WARNING: DO NOT USE THE HEATER UNTIL THE FEET OR WALL BRACKETS ARE FITTED CORRECTLY.
The product can be used as an installed or portable unit. Once the desired application has been decided upon and the requirements below have been met the product is ready to be used. Simply plug in and switch on at the wall socket. There are various control options available with various combinations comprising of thermostat, switched, timer & indicating neons.
Please note – the element has been coated with a protective lm which will burn off during the rst few minutes of use and may cause a small
amount of fuming. This is quite normal – the fumes are non-toxic and will quickly disappear.
We recommend that you open a window to ventilate the room when using
the heater for the rst time.
Positioning the heater
Always ensure that the heater is stood on a rm, level base near to, but
not directly beneath, a suitable mains supply socket. Ensure that curtains and furniture are not positioned close to the chosen
position, as this would create a potential re hazard.
We recommend that the heater should be wall-mounted in rooms where children may be left unattended, see ‘Important Safety Advice’.
Important Safety Advice
WARNING: This appliance must not be used in
a bathroom. WARNING: Do not use this heater in the immediate surroundings of a bath, a shower or a swimming pool. WARNING: This heater must not be located
immediately below a xed socket outlet.
The heater carries a warning symbol to
alert the user to the risk of re that exists
if the heater is accidentally covered. WARNING: In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience or knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Children of less than 3 years should be kept away unless continuously supervised. Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance. CAUTION: Some parts of this product can become very hot and cause burns. Particular
Dimensions
(Millimetres)
Installation and Operating Instructions
Dimplex Convector Heaters Models :
403TS, 403TSF, 403TSTi & 403TSFTie
08/52754/1 Issue 1
Models Specication
403TS 3.0kw Thermostat & 2 heat settings & Neon.
403TSF 3.0kw Thermostat, 2 heat settings, Turbo & Neon.
403TSTi 3.0kw Thermostat, 2 heat settings, Timer & Neon.
403TSFTie 3.0kw Thermostat, 2 heat settings, Timer & Turbo.
IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Fig. 1
Thermostat (all models)
The thermostat controls the heat output according to the room temperature. This ensures that the heater will not produce heat unnecessarily when the room is warm. To set the temperature you require, gradually turn the thermostat knob clockwise until the desired temperature is reached. Allow some time between increments for the room temperature to stabilise. Alternatively to heat a cold room quickly, turn the thermostat knob to the Max position. When the room has reached the desired temperature, turn the thermostat knob anti-clockwise until the thermostat clicks off. The heater will then automatically maintain this room temperature. The thermostat also has a frost protection setting marked ‘ ’. This setting is useful in areas such as garages to prevent frost damage. If the thermostat is set to its minimum setting ‘ ’, the heater will cycle ON and OFF to maintain a temperature of approximately 5°C to help protect against frosty conditions.
Switches (selected models)
Some models are supplied with selector switches . There are two switch types, one is an on/off switch and the other is a heat selection switch. Depending on model either one or both switch may be included. The switch operation is as follows.
On/ Off: O - Off I - On
Heat selection I - Low heat II - High heat
403TS Operation
This model contains an On/Off switch and a heat selection switch and operates as follows.
When O/I switch is in position O the product is off regardless of any other setting. When O/I switch is in position I and the I/II switch is in the I position there is a 2kw output from the product. When O/I switch is in position I and the I/II switch is in the II position there is a 3kW output from the product. The indicator neon is always on when the product is connected to the mains supply.
403TSTi Operation
This model contains a heat selection switch and an electro-mechanical timer and operates as follows.
When the timer is switched to I and the I/II switch is in position I there is a 2kW output from the product. When the timer is switched to I and the I/II switch is in position II there is a 3kW output from the product. When the timer is in the ‘ ’ position and the I/II switch is in position I there is a 2kW output from the product when the timer is set on. When the timer is in the ‘ ’ position and the I/II switch is in position II there is a 3kW output from the product when the timer is set on. The indicator neon is always on when the product is connected to the mains supply.
Mechanical Timer (403TSTi)
9
8
6
5
7
15
2
21
22
20
19
18
16
17
3
4
24
23
1
11
12
10
13
14
O
I
Set the I - - slide switch on the timer (Fig.7) to:
Position
- Heating Off
Position I - Manual operation
This setting allows power to the heater uninterrupted by the timer settings. The heat selector switch will control the output (see heater).
Position
- ‘Auto’ operation
DO NOT disconnect this heater from the mains
supply unless it is being taken out of use (e.g. in summer or for storage), otherwise the timer clock will stop.
9
8
I
10
O
Portable use
WARNING: THE HEATER SHOULD NEVER BE USED AS A PORTABLE APPLIANCE WITHOUT THE FEET SECURELY FITTED.
WARNING: ONLY THE SCREWS SUPPLIED WITH THIS PRODUCT SHOULD BE USED TO MOUNT THE FOOT. A MAXIMUM SCREW LENGTH OF 10MM SHOULD BE USED.
Lay the heater on its back and remove the wall mounting brackets - see
Wall mounting. Locate and remove the foot xing screw - see Fig. 2(a). Clip the foot in place and secure using the foot xing screw.
NOTE – The wall mounting brackets must be removed before the foot
can be tted.
Wall Mounting (Installed)
Three identical wall mounting brackets are secured to the base of the heater
with a xing screw. To wall mount appliance, rst remove the brackets as
follows, lay the heater on its back and follow the sequence shown - see
Fig. 3. Identify and remove the xing screw securing the brackets located
beside mains cable as shown in (a), pull out brackets and rotate them to disengage them from the slot and withdraw the brackets from the slot (b).
Select a suitable position, near to a mains power socket whilst ensuring the minimum mounting clearances are maintained - see Fig. 1. Fix the two top retaining brackets to the wall, using suitable xings – see Fig. 4.
478
574
Locate the heater on the top brackets and allow it to hang in place.
Fit the bottom bracket into the slot in the heater and then x it to the wall. Test that the heater is now securely xed to the wall.
Controls
Model 403TSTi
Model 403TSF
Heat selector switch
Thermostat knob
Neon
Mechanical Timer
Control switch
Thermostat knob
Neon
Fig. 6
Fig. 4
Fig. 5
Fig. 3
Fig. 2
Fig. 7