Dimplex 3071, 3072, 3077, 3073, 3078 Installation And Operating Instructions Manual

ContactDetails
Pleasenotethatsomeofthecontactdetailson
thisPDFdocumentmaynotbecurrent.
contactus:
Telephone:08448793588
Email:customer.services@gdcgroup.co.uk
 
Thecustomersupportsectionofourwebsitealsofeaturesawide rangeofinformationwhichmaybeofusetoyouandisavailable 24hoursaday.Itincludes:
Operatingandinstallationinstructions
Easy‘Howtouse’guidesforstorageheaters
Serviceandrepairs
Where
tobuyourproducts
Literaturedownloads
Heatingrequirementcalculator
 Visit‐www.dimplex.co.uk/support
A division of GDC Group Ltd Millbrook House Grange Drive Hedge End Southampton SO30 2DF www.dimplex.co.uk
Registered No: 1313016 England VAT GB 287 1315 50004 EEE Producer Registration Number – WEE/GE0057TS Paper from sustainable sources
Installation and Operating Instructions
Dimplex Convector Heaters
INDCUK307R Issue 4
Models : 3071, 3072, 3073, 3077 and 3078
357
432
MIN
Floor Mtd. Wall Mtd.
230
230
MIN
577 - 2.0kw
697 - 3.0kw
230 156
MIN
450 MIN
Dimensions
(millimetres)
Models Specification
3071 2.0kw Thermostat
3072 2.0kw Thermostat/24hr Timer/Neon
3073 2.0kw Switch/Thermostat
3077 2.0kw 2 Neon Switches/Thermostat/Turbo
3078 3.0kw 2 Switches/Thermostat/Neon
IMPORTANT S FETY ADVICE
3 No. Wall Mounting Brackets
floor
520 mm min.
3
k
w
-
4
7
8
m
m
c
e
n
t
r
e
s
2
k
w
-
3
5
8
m
m
c
e
n
t
r
e
s
526 mm min.
bracket slot
shelf / ceiling
A
WARNING –THIS APPLIANCE MUST NOT BE USED IN A BATHROOM WARNING - DO NOT USE THIS HEATER IN THE IMMEDIATE
SURROUNDINGS OF A BATH, A SHOWER OR A SWIMMING POOL. WARNING – THIS HEATER MUST NOT BE LOCATED IMMEDIATELY
BELOW A FIXED SOCKET OUTLET. DO NOT USE THE HEATER UNTIL THE FEET OR WALL BRACKETS
ARE FITTED CORRECTLY. FOLLOW these instructions carefully. NEVER cover or obstruct in any way the heat outlet slots at the top
of the heater or the air inlet slots in the base of the heater. The heater carries a warning ‘DO NOT COVER’ to alert the user to the
risk of fire that exists if the heater is accidentally covered. If young children, the aged or infirm are likely to be left in t he vicinit y
of the heater, we advise that adequate precautions should be taken.­We recommend that a guard be fitted to ensure contact with the heater is avoided and objects cannot be inserted into the product.
Model 3072 – this model can be set to switch on automatically , remember to observe all safety warnings at all times .
If the mains lead is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
For further information, please contact our guard supplier dir ect on Tel. No. 01603 667957, or in case of difficulty or for further ad vice contact the Customer Helpline.
WARNING: In order to avoid a hazard due to inadvertent resetting of the hrough an thermal cut-out, this appliance must not be supplied t external o a circuit switching device, such as a timer, or connected t that is regularly switched on and off by the utility.
WA
rked on
is fitted with
a re replacing the
S 1362
amp plug
ote that the ollowing code :
GR BLUE : BROWN : LIVE
Connect the GREEN AND YELLOW wire to the terminal marked ‘E’ or by the earth symbol
, or coloured GREEN or GREEN AND YELLOW.
Connect the BROWN wire to the terminal marked ‘L’ or coloured RED. Connect the BLUE wire to the terminal marked ‘N’ or coloured BLACK.
Wall Mounting
Three identical wall mounting brackets are secured to the base of the heater with a fixing screw. To wall mount appliance, first remove the brackets as follows : Lay the heater on its back. Following the sequence in Fig. 1 – identify and remove the fixing screw securing the brackets located beside Mains Cable as shown in (a), then pull out brackets and rotate them to disengage them from the slot (b). Withdraw the brackets from the slot (c).
(a) (b) (c)
Fig. 1
Select a suitable position on a wall, near to a mains power socket, making sure that there is at least 230 mm below the heater and at least 450 mm above the heater of unobstructed space. See also ‘Positioning the heater’. Fix the two top retaining brackets to the wall, using suitable fixings, for 2kw models at 358 mm centres and 3kw models at 478 mm centres – see Fig 2.
Fig. 2
Locate the heater on the top brackets and allow it to hang in place. Fit the bottom bracket into the slot in the heater and then fix it to the wall.
Test that the heater is now securely fixed to the wall.
Electrical connection
RNING – THIS APPLIANCE MUST BE EARTHED
This heater must be used on an ~ supply only and the voltage ma the heater must correspond to the supply voltage. This heater
wirable plug incorporating a 13 amp fuse. In the event of fuse in the plug supplied, a 13 amp fuse approved by ASTA to B must be used. If any other type of plug is used, a 15 amp fuse must be fitted in the plug, the adaptor, or at the distribution board. IMPORTANT : If the plug is not suitable for your socket, the 13 should be removed. Before wiring the appropriate plug, please n
wires in this mains lead are coloured in accordance with the f
EEN AND YELLOW : EARTH
NEUTRAL
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.