When installing and using this electrical equipment, basic safety
precautions should always be followed, including:
1) WARNING: To reduce the risk of injury, do not permit children to
use this product unless they are closely supervised at all times.
2) WARNING:A grounding wire connector is provided on this unit to
connect a minimum No. 8 AWG (8.4 mm2) solid copper conductor
between this unit and any metal equipment, metal enclosures of
electrical equipment, metal water pipe, or conduit within 5 feet (1.5
m) of the unit.
1
3) DANGER: Risk of Accidental Drowning. Extreme caution must be
exercised to prevent unauthorized access by children. To avoid
accidents, ensure that children cannot use this spa unless they are
supervised at all times.
4) DANGER: Risk of Injury. The suction fittings in this spa are sized
to match the specific water flow created by the pump. Should the
need arise to replace the suction fittings or the pump, be sure that the
flow rates are compatible.
Never operate the spa if the suction fittings are broken or missing.
Never replace a suction fitting with one rated less than the flow rate
marked on the original suction fitting.
5) DANGER: Risk of Electric Shock. Install at least 5 FEET (1.5 m),
from all metal surfaces. As an alternative, a spa may be installed
within 5 feet of metal surfaces if each metal surface is permanently
connected by a minimum No. 8 AWG (8.4 mm2) solid copper
conductor attached to the wire connector on the grounding lug, inside
the equipment compartment on the equipment can.
6) DANGER: Risk of Electric Shock. Do not permit any electrical
appliance, such as a light, telephone, radio, television, etc. within 5
feet of a spa.
1998 Owner’s Manual
7) E L E C T R I C A LS U P P LY:The electrical supply for this product must
include a suitably rated switch or circuit breaker to open all
ungrounded supply conductors to comply with section 422-20 of the
National Electrical Code, A N S I / N F PA 70-1993. The disconnect must
be readily accessible and visible to the spa occupant but installed at
least 5 feet (1.5 m), from the spa water.
8) WARNING: To Reduce the Risk of Injury:
a) The water in a spa should never exceed 104° F (40° C). Water
temperatures between 100° F (38° C) and 104° F (40° C) are
considered safe for a healthy adult. Lower water temperatures are
recommended for young children and when spa use exceeds 10
minutes.
b) Since excessive water temperatures have a high potential for
causing fetal damage during the early months of pregnancy,
pregnant or possibly pregnant women should limit spa water
temperatures to 100° F (38° C).
c) Before entering a spa, the user should measure the water
temperature with an accurate thermometer since the tolerance of
water temperature-regulating devices may vary as much as +/- 5°
F (2° C).
d) The use of alcohol, drugs, or medication before or during spa use
may lead to unconsciousness with the possibility of drowning.
e) Persons suffering from obesity or with a medical history of heart
disease, low or high blood pressure, circulatory system problems,
or diabetes should consult a physician before using a spa.
f)Persons using medication should consult a physician before using
a spa since some medication may induce drowsiness, while other
medication may affect heart rate, blood pressure, and circulation.
2
IMPORTANT SAFETY INSTRUCTIONS
(CSA SAFETY INFORMATION)
When using this electrical equipment, basic safety precautions should
always be followed, including the following:
a) READ AND FOLLOW ALL INSTRUCTIONS.
b) Agreen coloured terminal or a terminal marked G, GR, Ground,
1998 Owner’s Manual
Grounding, or the symbol * is located inside the supply terminal
box or compartment. To reduce the risk of electric shock, this
terminal must be connected to the grounding means provided in the
electric supply service panel with a continuous copper wire
equivalent in size to the circuit conductors supplying this equipment.
* IEC Publication 417, Symbol 5019.
c) At least two lugs marked “BONDING LUGS” are provided on the
external surface or on the inside of the supply terminal
box/compartment. To reduce the risk of electric shock, connect the
local common bonding grid in the area of the hot tub or spa to these
terminals with an insulated or bare copper conductor not smaller than
No. 6 AWG.
d) All field-installed metal components such as rails, ladders, drains or
other similar hardware within 3 M of the spa or hot tub shall be
bonded to the equipment grounding bus with copper conductors not
smaller than No. 6 AWG.
3
e) SAVE THESE INSTRUCTIONS.
WARNING: Children should not use spas or hot tubs without adult
supervision.
AVERTISSEMENT: NE PAS LAISSER LES ENFANTS UTILISER UNE
CUVE DE RELAXATION SANS SURVEILLANCE.
WARNING: Do not use spas or hot tubs unless all suction guards are
installed to prevent body and hair entrapment.
AVERTISSEMENT: POUR ÉVITER QUE LES CHEVEUX OU UNE
PARTIE DU CORPS PUISSENT ÊTRE ASPIRÉS, NE PAS UTILISER
UNE CUVE DE RELAXATION SI LES GRILLES DE PRISE
D’ASPIRATION NE SONT PAS TOUTES EN PLACE.
WARNING: People using medications and/or having adverse medical
history should consult a physician before using a spa or hot tub.
AVERTISSEMENT: LES PERSONNES QUI PRENNENT DES
MÉDICAMENTS OU ONT DES PROBLÈMES DE SANTÉ DEVRAIENT
CONSULTER UN MÉDECIN AVANT D’UTILISER USE CUVE DE
RELAXATION.
1998 Owner’s Manual
WARNING: People with infectious diseases should not use a spa or hot
tub.
AVERTISSEMENT: LES PERSONNES ATTEINTES DE MALADIES
INFECTIEUSES NE DEVRAIENT PAS UTILISER UNE CUVE DE
RELAXATION.
WARNING: To avoid injury exercise care when entering or exiting the
spa or hot tub.
AVERTISSEMENT: POUR ÉVITER DES BLESSURES, USER DE
PRUDENCE EN ENTRANT DANS UNE CUVE DE RELAXATION ET E
SORTANT.
4
WARNING: Do not use drugs or alcohol before or during the use of a
spa or hot tub to avoid unconsciousness and possible drowning.
AVERTISSEMENT: POUR ÉVITER L’ÉVANOUISSEMENTET LA
NOYADE EVENTUELLE, NE PRENDRE NI DROGUE NI ALCOOL
AVANT D’UTILISER UNE CUVE DE RELAXATION NI QUAND ON S’Y
TROUVE.
WARNING: Pregnant or possibly pregnant women should consult a
physician before using a spa or hot tub.
AVERTISSEMENT: LES FEMMES ENCEINTES, QUE LEUR
GROSSESSE SOIT CONFIRMÉE OU NON, DEVRAIENT CONSULTER
UN MÉDECIN AVANT D’UTILISER UNE CUVE DE RELAXATION.
WARNING: Water temperature in excess of 38˚ C may be injurious to
your health.
AVERTISSEMENT: IL PEUT ÊTRE DANGEREUX POUR LA SANTÉ
DE SE PLONGER DANS DE L’EAU À PLUS DE 38˚ C.
WARNING: Before entering the spa or hot tub, measure the water
temperature with an accurate thermometer.
AVERTISSEMENT: AVANT D’UTILISER UNE CUVE DE
RELAXATION MESURER LA TEMPÉRATURE DE L’EAU À L’AIDE
D’UN THERMOMÈTRE PRÉCIS.
1998 Owner’s Manual
WARNING: Do not use a spa or hot tub immediately following
strenuous exercise.
AVERTISSEMENT: NE PAS UTILISER UNE CUVE DE RELAXATION
IMMEDIATEMENT APRÈS UN EXERCICE SATIGANT.
WARNING: Prolonged immersion in a spa or hot tub may be injurious
to your health.
AV E R T I S S E M E N T: L’ U T I L I S ATION PROLONGÉE D’UNE CUVE DE
R E L A X ATION PEUT ÊTRE DANGEREUSE POUR LA S A N T É .
WARNING: Do not permit electric appliances (such as a light,
telephone, radio, television, etc.) within 1.5 m of this spa or hot tub.
5
AVERTISSEMENT: NE PAS PLACER D’APPAREIL ÉLECTRIQUE
(LUMINAIRE, TÉLÉPHONE, RADIO, TÉLÉVISEUR, ETC.) À MOINS
DE 1.5 M DE CETTE CUVE DE RELAXATION.
CAUTION: Maintain water chemistry in accordance with
manufacturer’s instructions.
ATTENTION: LA TENEUR DE L’EAU EN MATIERÈS DISSOUTES
DOIT ÊTRE CONFORME AUX DIRECTIVES DU FABRICANT.
HYPERTHERMIA
Prolonged immersion in hot water may induce hyperthermia. A
description of the causes, symptoms, and effects of hyperthermia are as
follows:
Hyperthermia occurs when the internal temperature of the body reaches a
level several degrees above the normal body temperature of 98.6˚ F, or
37˚ C. The symptoms of hyperthermia include drowsiness, lethargy, and
an increase in the internal temperature of the body. The effects of
hyperthermia include:
a)Unawareness of impending hazard;
b)Failure to perceive heat;
c)Failure to recognize the need to exit spa;
d)Physical inability to exit spa;
1998 Owner’s Manual
e)Fetal damage in pregnant women; and
f)Unconsciousness and danger of drowning.
WARNING: The use of alcohol or drugs can greatly increase the risk of
fatal hyperthermia in hot tubs and spas.
AVERTISSEMENT: LA CONSOMMATION D’ALCOOL OU DE
DROGUE AUGMENTE CONSIDÈRABLEMENT LES RISQUES
D’HYPERTHERMIE MORTELLE DANS UNE CUVE DE RELAXATION.
SAVE THESE INSTRUCTIONS
CAUTIONS
6
1) Persons suffering from heart disease, diabetes, high or low blood
pressure, any condition requiring medical treatment, pregnant women,
the elderly, or infants should consult with a physician before using a
spa.
2) The consumer products safety commission has stated that the water
temperature in a spa or hot tub should not exceed
104° F. Immersion in water in excess of 104° F can be hazardous to
your health.
3) Observe a reasonable time limit when using the spa. Long exposures
at higher temperatures can cause high body temperature. Symptoms
may include dizziness, nausea, fainting, drowsiness, and reduced
awareness. These effects could result in possible drowning.
4) Do not use the spa under the influence of alcohol, narcotics, or other
drugs. Use of the spa under these conditions may lead to serious
consequences.
5) Always test the spa water temperature before entering the spa. Enter
and exit the spa slowly. Wet surfaces can be very slippery.
6) Never bring any electrical appliances into or near the spa. Never
operate any electrical appliances from inside the spa or when you are
wet.
7) Proper chemical maintenance of spa water is necessary to maintain
safe water and prevent possible damage to spa components.
8) Use the spa straps and clip tie downs to secure the cover when not in
use. This will help to discourage unsupervised children from entering
1998 Owner’s Manual
the spa and keep the spa cover secure in high-wind conditions. There
is no representation that the cover, clip tie downs, or actual locks will
prevent access to the spa.
DO’S AND DON’TS
• DO test water temperature with your hand before entering to be sure
that it’s comfortable.
• DO keep the spa cover closed when the spa is not in use. This is also
the key to economical spa operation.
• DON’T block the ventilated equipment compartment door. Blockage
may cause damage to the spa equipment and will void the warranty.
• DON’T block the filter recess area.
7
1998 Owner’s Manual
WARNING SIGN
Each spa has been provided with a warning sign which outlines safety
precautions. This sign should be permanently placed in a location that is
visible to the spa user. Replacement signs can be obtained from:
WARNING
8
Dimension One Spas
2611 Business Park Drive
Vista, CA 92083
760.727.7727
SPA FEATURES
Congratulations! You have purchased one of the finest portable spas
available. Take the time to read these instructions carefully. If installed
and maintained properly your spa will provide many years of enjoyable,
trouble-free operation. Read all of the instructions and view your owner's
manual video for further reference on spa operation. If you have any
questions, please contact your local Authorized Dimension One Spas
Dealer.
The following features are included on your spa:
• UL listed/CUL approved
1998 Owner’s Manual
9
• Completely self-contained with load sharing capabilities
• 100% foam insulated
• All spa shells are formed from UltraLife
™
high impact thermo-
plastic, or Quarite Plus™Acrylic
• Designed for indoor or outdoor usage
• Top access, easy to clean filter systems
• Water level referencing weir skimmer
• Handcrafted cabinets
• A variety of interchangeable HydraFlex
™
Jets
• Multiple jet systems with Selector Valve
• Exclusive, custom designed tile coordinates with shell material
and control panel
• Polyethylene floor completely seals the spa, eliminating moisture or insect intrusion
• Built-in, automatic freeze protection
• Automatic high/low speed filtration cycles
1998 Owner’s Manual
Additional features of the, Diplomat, Chairman, Californian,
Nautilus, Aurora I and Aurora II:
• Scrolling Message Center with digital display self-diagnostic,
instructional, and maintenance messages
• Ultra Pure™Water Management System
• NeckFlex™Jet Pillow
• Twin long life, 4.0 HP, dual speed HydraMax®pumps on the
Diplomat, and Chairman; Twin long life, 3.0 HP, dual speed
HydraMax pumps on the Californian, Nautilus and Aurora II;
and one long life, 4.0 HP, dual speed HydraMax pump on the
Aurora I.
• 115 sq. ft. of filtration
10
Additional features of the Interlude, Arena, Quadra and Triad:
• Programmable Digital control with digital read-out and self
diagnostics
• Pre-plumbed for the optional CrystalZone™Water Management
System
• Long life, 4.0 HP, dual speed HydraMax pump on the Arena
Interlude and Triad; and 1.5 HP, dual speed HydraMax pump on
the Quadra
• 75 sq. ft. of filtration
JET SYSTEM SELECTOR VALVE
All spas are equipped with spaside Selector Valves. These valves can be
used to divert jet power from one area within the spa to another. The
valves are infinitely adjustable and can be used to suit the bather's taste.
The valves may offer some resistance to operation when the spa pump is
on. This is a normal condition, and is caused by the high rate of water
flow and pressure that travels through the valves.
JET OPTIONS
Dimension One Spas jetting systems provide complete flexibility in personalizing hydrotherapy sessions. The HydraFlex Jet™is the most versatile jet in the industry. It allows you to adjust the flow and pressure of
the jet for each specific muscle group. Awide variety of interchangeable
jet styles allow you to control and modify massage patterns at any seat in
the spa to personalize your massage to your own preference.
1998 Owner’s Manual
Additionally, the Variable Circulation Rotator jet can be adjusted to user
preference, adding to the overall flexibility of the spa's jetting systems.
The AquaPed foot jet located in the bottom of the footwell of the
Californian, Nautilus, Aurora I, Aurora II, and Arena also has a variety of
interchangeable nozzles for different patterns. Likewise, the whirlpool jet
found in the Nautilus and Arena may use these interchangeable nozzles.
Contact your local Authorized Dimension One Spas Dealer for more
information on the availability of optional jet styles.
NECKFLEX JET PILLOW
The NeckFlex Jet offers five position adjustable pillow heights to accommodate different body sizes. The standard mini directional jets can be
interchanged with rotating jets and adjusted for water volume. See your
local Authorized Dimension One Spas Dealer for more information.
11
ULTRA PURE WATER MANAGEMENT SYSTEM
The Diplomat, Chairman, Californian, Nautilus, Aurora I and Aurora II
are equipped with a highly advanced spa water treatment method, the
Ultra Pure Water Management System. Ultra Pure is a complete water
management system with two-stages of ozone injection, two contact
chambers, 100% filtration, and heating on call.
How the system works: First, Ultra Pure circulates the water through a
dedicated, 40 sq. ft. filter (located in the 5” canister in the skimmer
recess), removing all debris and large contaminant particles. The filtered
water passes through the heater and then travels to the first ozone injection stage which employs the use of a Mazzei-T injector (a negative pressure Venturi system). The Mazzei injector then mixes the ozone gas into
solution as it agitates through 12 feet of corrugated contact plumbing (1st
contact chamber). This chamber allows the ozone ample time to get into
solution and begin the oxidation process.
Any gas that has not dissolved while traveling through this first chamber
is fired downward into a standpipe, to increase the resident time of the
gas in a secondary, contact chamber. After the ozone bubbles have traveled down the stand pipe, inside the secondary chamber, the off-gas bubbles will then rise and merge in an air reservoir (the smaller bubbles coalesce and turn into larger bubbles). As the air builds in the reservoir, it is
1998 Owner’s Manual
combined with water and re-injected through a secondary ozone jet back
into the spa, virtually eliminating the negative attributes of off gassing
experienced with conventional systems.
The Ultra Pure Water Management System provides the most efficient
method of mixing ozone gas into solution while delivering 100% filtration, ozonization, and heat on demand. Bottom line... Ultra Pure allows
you to spend less time maintaining your spa and more time enjoying it.
ULTRAVISION
The Ultra Pure Water Management System can be used in conjunction
with UltraVision, an alternative purification cartridge that can be added to
the 5” filter canister. In use, its advantages over conventional halogens
(bromine and chlorine) can be softer-feeling water and lower maintenance. Additionally, low chemical levels can also mean less dissolved
solids and fewer maintenance adjustments. PureVision, an UltraVision
counterpart, can be used in conjunction with the optional CrystalZone
Water Management System.
12
How UltraVision and Purevision Work: The UltraVision purification
cartridge, which has no moving parts and requires no electrical connections, contains a powerful, silver catalyst bed with a very large surface
area. In the Ultra Pure system, water flows through the purification cartridge, then through the dedicated, 40 sq. ft. filter (PureVision uses the
standard 75 sq. ft. filter), and then through a heater housing before being
ozonated and returned to the spa. During the process, the Silver (Ag)
residual is put into the water, which acts as a bactericide. When used in
the Ultra Pure or CrystalZone Water Management Systems, UltraVision
and PureVision provide a natural, residual bactericide which compliments
the ozone oxidizing power. After excessive bather loads, however, an
additional oxidizer may be required to remove accumulated organic compounds. Be sure to carefully follow the included instructions for proper
use - DO NOT follow the standard water chemistry start-up procedures
contained in this manual.
WARNING: While Vision is a bactericide which can be safely used as a
replacement for conventional halogens, it is not a “chemical free” system.
In order to gain the maximum benefits of Vision products, follow the
manufacturer’s directions. All other aspects and adjustments of water
1998 Owner’s Manual
chemistry such as pH and total alkalinity must adhere to the manufacturer’s instructions relative to that specific product. As Dimension One
Spas has no control over the water source used in any spa application, it
will not be responsible for any staining below the water line and any such
occurrence will not be covered under any of its warranties.
HEATER AND CIRCULATION PUMPCONTROL
On all Dimension One Spas, when the water temperature is 1˚ below the
set temperature the heater will turn on and remain on until the water temperature rises to 1˚ above the set temperature. On models that do not
have circulation pumps (Interlude, Arena, Triad and Quadra without the
CrystalZone Water Management System) the low speed pump will turn
on during the heating cycle.
13
On models with Ultra Pure (Chairman, Diplomat, Californian, Nautilus,
Aurora II and Aurora I) and models with the Crystal Zone Water
Management System: To prevent the spa from overheating, the circulation pump turns off when the water temperature rises 2˚ above the set
temperature. When the water temperature cools down to the set temperature, the circulation pump will turn on.
NOTE: The circulation pump will run for short periods when the water
temperature is 2˚ above set temperature to provide optimum operation.
BEFORE ATTEMPTING TO HOOK-UP OR USE YOUR SPA,
PLEASE READ THROUGH THESE INSTRUCTIONS AND CAREFULLY VIEW YOUR OWNER'S MANUAL VIDEO.
Loading...
+ 34 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.