2003 Dimension One Spa s and @ Home Hot Tubs
Planning Guide and Installation Manual
IV
2003 Dimension One Spa s and @ Home Hot Tubs |
|
Planning Guide and Installation Manual |
|
Table of Contents |
|
PRE-PURCHASE DECISIONS...................................................................................................................... |
1 |
BEFORE DELIVERY .................................................................................................................................. |
1 |
Typical Installation Site.................................................................................................................................................................................. |
1 |
SITE ACCESS............................................................................................................................................. |
2 |
COVER........................................................................................................................................................ |
2 |
ELECTRICAL HOOK UP .............................................................................................................................. |
3 |
LOAD SHARING ....................................................................................................................................... |
3 |
ELECTRICAL REQUIREMENTS ............................................................................................................. |
4 |
Domestic D1 Hot Tubs................................................................................................................................................................................. |
4 |
Export D1 Hot Tubs ...................................................................................................................................................................................... |
5 |
Domestic @ Home Hot Tubs..................................................................................................................................................................... |
6 |
Export @ Home Hot Tubs.......................................................................................................................................................................... |
6 |
INSTALLATION CHECK LIST ............................................................................................................... |
7 |
HOT TUB SPECIFICATIONS...................................................................................................................... |
7 |
SPECIFICATIONS FOR DIMENSION ONE SPAS ............................................................................... |
7 |
Arena – Architectural Specifications .......................................................................................................................................................... |
8 |
Arena – General Specifications ................................................................................................................................................................... |
9 |
Aurora II – Architectural Specifications.................................................................................................................................................. |
10 |
Aurora II – General Specifications........................................................................................................................................................... |
11 |
Aurora HP – Architectural Specifications .............................................................................................................................................. |
12 |
Aurora HP – General Specifications ....................................................................................................................................................... |
13 |
Caliente – Architectural Specifications................................................................................................................................................... |
14 |
Caliente – General Specifications............................................................................................................................................................ |
15 |
Caliente HP – Architectural Specifications............................................................................................................................................ |
16 |
Caliente HP – General Specifications..................................................................................................................................................... |
17 |
Californian – Architectural Specifications.............................................................................................................................................. |
18 |
Californian – General Specifications....................................................................................................................................................... |
19 |
Chairman – Architectural Specifications................................................................................................................................................ |
20 |
Chairman – General Specifications......................................................................................................................................................... |
21 |
Chairman II – Architectural Specifications............................................................................................................................................ |
22 |
Chairman II – General Specifications..................................................................................................................................................... |
23 |
Diplomat – Architectural Specifications................................................................................................................................................. |
24 |
Diplomat – General Specifications.......................................................................................................................................................... |
25 |
Nautilus – Architectural Specifications................................................................................................................................................... |
26 |
Nautilus – General Specifications............................................................................................................................................................ |
27 |
Sarena Bay – Architectural Specification............................................................................................................................................... |
28 |
Sarena Bay – General Specifications...................................................................................................................................................... |
29 |
Triad – Architectural Specifications ........................................................................................................................................................ |
30 |
Triad – General Specifications ................................................................................................................................................................. |
31 |
Triad II – Architectural Specifications..................................................................................................................................................... |
32 |
Triad II – General Specifications.............................................................................................................................................................. |
33 |
iii
2003 Dimension One Spa s and @ Home Hot Tubs |
|
Planning Guide and Installation Manual |
|
SPECIFICATIONS FOR @HOME HOT TUBS ................................................................................... |
34 |
Companion HP – Architectural Specifications...................................................................................................................................... |
34 |
Companion HP – General Specifications............................................................................................................................................... |
35 |
Cove – Architectural Specifications ......................................................................................................................................................... |
36 |
Cove – General Specifications .................................................................................................................................................................. |
37 |
Cove HP – Architectural Specifications .................................................................................................................................................. |
38 |
Cove HP – General Specifications ........................................................................................................................................................... |
39 |
Dream – Architectural Specifications ..................................................................................................................................................... |
40 |
Dream – General Specifications .............................................................................................................................................................. |
41 |
Dream HP – Architectural Specifications.............................................................................................................................................. |
42 |
Dream HP – General Specifications....................................................................................................................................................... |
43 |
Sojourn HP – Architectural Specifications ............................................................................................................................................. |
44 |
Sojourn HP – General Specifications ...................................................................................................................................................... |
45 |
WIRING DIAGRAMS .................................................................................................................................. |
46 |
SPA INFORMATION .................................................................................................................................. |
46 |
My Spa............................................................................................................................................................................................................ |
46 |
Dealer Information: ..................................................................................................................................................................................... |
46 |
Dimension One Spas Inc. Information ................................................................................................................................................... |
46 |
iv
2003 Dimension One Spas and @ Home Hot Tubs
Planning Guide and Installation Manual
Before attempting to install or use your hot tub, please read these instructions thoroughly, and carefully review the owner’s manual for your
Dimension One hot tub! Because your hot tub is completely self-contained, you can install it just about anywhere you wish . . . on a deck, patio or even indoors. Just be sure to position it above ground, in an area with good drainage and on a level surface that fully contacts the bottom of the hot tub.
A concrete slab is best but not
required. You may choose to install it on a
wood deck or bricks. If you choose to install your hot tub on a raised deck or indoors, we suggest you contact a structural engineer to confirm the surface will hold a hot tub filled with water. Settlement of your deck or slab may result in damage to the hot tub, which is not covered by warranty. (See specifications in this booklet.) Wherever you plan to install your hot tub, be sure the surface is flat and solid. Locate your hot tub so that the equipment is above grade and not subject to flooding. Water should always drain away from the hot tub. If you are placing your hot tub next to an obstacle, such as a fence or wall, be sure that you place the hot tub with the topside primary control panel facing forward for easy equipment access. Locate the vents on the drawing of your particular Dimension One hot tub. This is where cool air will enter and warm air will escape during hot tub operation. Please ensure that these areas are always free of obstructions. Also, allow additional space around the hot tub for any accessories you may have purchased - for example an E-Z Lifter® spa cover lift, steps, or a gazebo. Check with your dealer on these additional space requirements.
In most cities and counties, permits are required for the installation of electrical circuits or the construction of exterior structures such as decks and gazebos. Some communities have
Note
also adopted residential barrier codes that may require fencing and/or self-closing gates on the property to prevent unsupervised access to a hot tub by young children.
If you install the spa or hot tub indoors, the surrounding area should be waterproof or water resistant. Water may be splashed out during normal usage and when entering or
Note
exiting the spa. Dimension One Spas is not responsible for any water damage to any indoor location for any reason.
Dimension One Spas and @Home Hot Tubs are equipped with a locking cover that meets or exceeds the “Standard for Safety Covers,” but is not an adequate safety measure to prevent unsupervised entry. Please check with your local Building Permit Office that can inform you on any special requirements needed for installation of your electrical, decking or required barriers. Your local dealer may also provide you with information on local building and electrical codes.
1
2003 Dimension One Spa s and @ Home Hot Tubs
Planning Guide and Installation Manual
Please refer to the drawings on pages 7 - 45 for the specifications and appropriate measurements for your hot tub model. You will need the measurements of your hot tub in order to determine the clearance needed for delivery.
DUE TO MANUFACTURING TOLERANCES THERE COULD BE SOME MINOR DIFFERENCES BETWEEN THE ACTUAL MEASUREMENTS OF YOUR SPA AND THE
Caution
DRAWING BELOW. IF SITE PLANNING IS CRITICAL TO SUCH TOLERANCES, BE SURE TO MEASURE YOUR ACTUAL SPA.
Your hot tub will probably be delivered on a dolly or cart. The additional distance from the ground to the dolly or cart must also be included in your measurements for vertical clearance. Also, take into consideration that if your hot tub must be transported up-hill or taken upstairs, you may need additional clearance or assistance. Be sure to remove obstacles such as gates, planters, or items attached to the house. The point of entry must be clear of air conditioning units, heating units, meters, electrical boxes, etc. It is best that your dealer pre-inspect the installation site and determine the best way to deliver your hot tub. In rare cases, a crane must be brought in to assist in an installation. Your Dimension One dealer will supervise this for you. Here is a list of some of the most common installation hazards in planning your route:
Gates |
Hose Bibs |
Fences |
Bushes |
Eaves |
Overhanging Branches |
Gutters |
Steps |
Air Conditioners |
90° Turns |
Heaters |
|
The cover supplied with your hot tub is constructed of the highest quality materials and is equipped with quickrelease keyed buckle locks that meet standards set by American Standards for Testing and Measurement (ASTM). When the hot tub is not in use, it is recommended that the cover locks always be utilized to discourage unsupervised use and to minimize heat loss. When installing the cover on your hot tub, be sure it is facing the correct direction. When standing in front of the topside primary control panel, the center seam or hinge should run horizontally. You should be able to lift the handle of the cover and see the hot tub control panel. Allow 18 inches of extra space on the backside of the hot tub where the optional E-Z Lifter® will rest in its upright, open position.
2
2003 Dimension One Spas and @ Home Hot Tubs
Planning Guide and Installation Manual
Do not turn on electrical power to your hot tub until told to do so later in this manual.
Warning
Have a licensed electrician run the required 120/240 volt power line to the hot tub installation site. The power inlet connection is located in the pedestal on the left side of the hot tub, approximately 25” from the front. This connection is designed to mate with a Carlon 1” conduit body Type LB, Access Fitting E986F or any 1” female PVC conduit fitting. The manufacturer’s label lists the power requirements for your hot tub.
We recommend that only a licensed and bonded electrician do the initial hot tub hook-up.
This unit requires a GFCI (Ground Fault Circuit Interrupter). A “line of sight” service disconnect must be located where visible from the hot tub, not less than 5 feet from
Warning
the hot tub and not to exceed 50 feet from the hot tub. This requirement may be filled with the GFCI sub-panel. All supply wire to be rated minimum 90°C.
Computerized load sharing (available only on Dimension One Spas hot tubs) is used to allow the system to automatically recognize the temperature differential and the number of jet pumps in use, compare it with the available power, and adjust the heater to maximize heater output. If you want to be able to run the pumps at full power and still be able to generate heat at the same time, consider installing the maximum electrical service available for your spa. If you do not have enough electrical service, your pumps may shut off when heat is required. Otherwise, heat may be discontinued if you start up the pumps.
3
2003 Dimension One Spa s and @ Home Hot Tubs
Planning Guide and Installation Manual
The following charts provide a listing of electrical requirement options available for Dimension One Spas Inc. and @Home Hot Tub spas.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Circuit |
|
|
Wire |
|
|
Model |
Power |
Branch Circuit |
|
Protection |
|
|
Gauge |
|
|
Arena |
240V |
3 wire + ground |
|
40A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
30A |
|
|
#8 AWG |
|
|
Aurora II |
240V |
3 wire + ground |
|
50A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
40A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
30A |
|
|
#8 AWG |
|
|
Aurora HP |
240V |
3 wire + ground |
|
50A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
40A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
30A |
|
|
#8 AWG |
|
|
Caliente |
240V |
3 wire + ground |
|
40A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
30A |
|
|
#8 AWG |
|
|
Caliente HP |
240V |
3 wire + ground |
|
50A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
40A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
30A |
|
|
#8 AWG |
|
|
Californian |
240V |
3 wire + ground |
|
50A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
40A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
30A |
|
|
#8 AWG |
|
|
Chairman |
240V |
3 wire + ground |
|
50A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
40A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
30A |
|
|
#8 AWG |
|
|
Chairman II |
240V |
3 wire + ground |
|
50A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
40A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
30A |
|
|
#8 AWG |
|
|
Diplomat |
240V |
3 wire + ground |
|
50A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
40A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
30A |
|
|
#8 AWG |
|
|
Nautilus |
240V |
3 wire + ground |
|
50A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
40A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
30A |
|
|
#8 AWG |
|
|
Sarena Bay |
240V |
3 wire + ground |
|
50A |
|
|
#6 AWG |
|
|
Triad |
240V |
3 wire + ground |
|
40A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
30A |
|
|
#8 AWG |
|
|
Triad II |
240V |
3 wire + ground |
|
40A |
|
|
#6 AWG |
|
|
|
240V |
3 wire + ground |
|
30A |
|
|
#8 AWG |
|
4
2003 Dimension One Spas and @ Home Hot Tubs
Planning Guide and Installation Manual
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Circuit |
|
|
Wire |
|
|
|
Model |
|
|
Power |
|
|
Circuit |
|
|
Wire |
|
|
Model |
Power |
|
Protection |
|
|
Gauge |
|
|
|
|
|
|
|
|
|
Protection |
|
|
Gauge |
|
|
Arena |
240V |
|
1x16 |
|
|
#8 AWG |
|
|
|
Chairman II |
|
|
240V |
|
|
1x16 |
|
|
#8 AWG |
|
|
|
240V |
|
2x16 |
|
|
#8 AWG |
|
|
|
|
|
|
240V |
|
|
2x16 |
|
|
#8 AWG |
|
|
|
240V |
|
1x32 |
|
|
#6 AWG |
|
|
|
|
|
|
240V |
|
|
1x32 |
|
|
#6 AWG |
|
|
Aurora II |
240V |
|
1x16 |
|
|
#8 AWG |
|
|
|
Diplomat |
|
|
240V |
|
|
1x16 |
|
|
#8 AWG |
|
|
|
240V |
|
2x16 |
|
|
#8 AWG |
|
|
|
|
|
|
240V |
|
|
2x16 |
|
|
#8 AWG |
|
|
|
240V |
|
1x32 |
|
|
#6 AWG |
|
|
|
|
|
|
240V |
|
|
1x32 |
|
|
#6 AWG |
|
|
Aurora HP |
240V |
|
1x16 |
|
|
#8 AWG |
|
|
|
Nautilus |
|
|
240V |
|
|
1x16 |
|
|
#8 AWG |
|
|
|
240V |
|
2x16 |
|
|
#8 AWG |
|
|
|
|
|
|
240V |
|
|
2x16 |
|
|
#8 AWG |
|
|
|
240V |
|
1x32 |
|
|
#6 AWG |
|
|
|
|
|
|
240V |
|
|
1x32 |
|
|
#6 AWG |
|
|
Caliente |
240V |
|
1x16 |
|
|
#8 AWG |
|
|
|
Sarena Bay |
|
|
240V |
|
|
1x16 |
|
|
#8 AWG |
|
|
|
240V |
|
2x16 |
|
|
#8 AWG |
|
|
|
|
|
|
240V |
|
|
2x16 |
|
|
#8 AWG |
|
|
|
240V |
|
1x32 |
|
|
#6 AWG |
|
|
|
|
|
|
240V |
|
|
1x32 |
|
|
#6 AWG |
|
|
Caliente HP |
240V |
|
1x16 |
|
|
#8 AWG |
|
|
|
Triad |
|
|
240V |
|
|
2x16 |
|
|
#8 AWG |
|
|
|
240V |
|
2x16 |
|
|
#8 AWG |
|
|
|
|
|
|
240V |
|
|
3x16 |
|
|
#8 AWG |
|
|
|
240V |
|
1x32 |
|
|
#6 AWG |
|
|
|
|
|
|
240V |
|
|
1x32 |
|
|
#6 AWG |
|
|
Californian |
240V |
|
1x16 |
|
|
#8 AWG |
|
|
|
Triad II |
|
|
240V |
|
|
1x16 |
|
|
#8 AWG |
|
|
|
240V |
|
2x16 |
|
|
#8 AWG |
|
|
|
|
|
|
240V |
|
|
2x16 |
|
|
#8 AWG |
|
|
|
240V |
|
1x32 |
|
|
#6 AWG |
|
|
|
|
|
|
240V |
|
|
1x32 |
|
|
#6 AWG |
|
|
Chairman |
240V |
|
1x16 |
|
|
#8 AWG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
240V |
|
2x16 |
|
|
#8 AWG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
240V |
|
1x32 |
|
|
#6 AWG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The power inlet connection is located in the pedestal on the left side of the hot tub, approximately 25" from the front. The front of the hot tub is the section that includes the topside, primary control panel.
To hook-up your hot tub, follow these instructions:
1.Remove the screws holding the equipment access panel to the front of the hot tub cabinet and set the panel aside.
2.Loosen the four screws located on the front of the black equipment control box and remove the door from the control box to allow access to the four-wire connection terminal block.
3.Attach 1” rigid non-metallic conduit to the conduit nipple located in the pedestal base on the side of the hot tub and run required conductors through the conduit to the equipment control box.
4.Connect the wires to the equipment system terminal block (TB1) as indicated on the wiring diagram in the back of this manual.
5.Configure jumpers 1 and 2 on the upper right corner of the PC Board to match the circuit size being used for your hot tub. The proper jumper settings can be found on the wiring schematic located on the inside of the Lower Equipment Compartment cover. Use the appropriate Electrical Requirements Chart (shown above) for the proper wire size.
5
2003 Dimension One Spa s and @ Home Hot Tubs
Planning Guide and Installation Manual
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Model |
|
|
Power |
|
|
Branch Circuit |
|
|
Circuit |
|
Wire |
|
|
|
|
|
|
|
|
|
|
|
Protection |
|
Gauge |
|
|
Companion HP |
|
|
240V |
|
|
3 wire + ground |
|
|
30A |
|
#8 AWG |
|
|
Cove |
|
|
240V |
|
|
3 wire + ground |
|
|
40A |
|
#6 AWG |
|
|
|
|
|
240V |
|
|
3 wire + ground |
|
|
30A |
|
#8 AWG |
|
|
|
|
|
120V |
|
|
3 wire + ground* |
|
|
15A |
|
#12AWG |
|
|
Cove HP |
|
|
240V |
|
|
3 wire + ground |
|
|
40A |
|
#6 AWG |
|
|
|
|
|
240V |
|
|
3 wire + ground |
|
|
30A |
|
#8 AWG |
|
|
Dream |
|
|
240V |
|
|
3 wire + ground |
|
|
30A |
|
#8 AWG |
|
|
Dream HP |
|
|
240V |
|
|
3 wire + ground |
|
|
40A |
|
#6 AWG |
|
|
|
|
|
240V |
|
|
3 wire + ground |
|
|
30A |
|
#8 AWG |
|
|
Sojourn HP |
|
|
240V |
|
|
3 wire + ground |
|
|
40A |
|
#6 AWG |
|
|
|
|
|
240V |
|
|
3 wire + ground |
|
|
30A |
|
#8 AWG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*A GFCI protected cord is required (P/N 1560-09)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Model |
|
|
Power |
|
|
Circuit |
|
|
Wire |
|
|
|
|
|
|
|
|
|
Protection |
|
|
Gauge |
|
|
|
Companion HP |
|
|
240V |
|
|
1x16 |
|
|
#8 AWG |
|
|
|
|
|
|
240V |
|
|
2x16 |
|
|
#8 AWG |
|
|
|
|
|
|
240V |
|
|
1x32 |
|
|
#6 AWG |
|
|
Cove |
|
240V |
|
|
1x16 |
|
|
#8 AWG |
|
||
|
|
|
|
240V |
|
|
2x16 |
|
|
#8 AWG |
|
|
|
|
Cove HP |
|
|
240V |
|
|
1x16 |
|
|
#8 AWG |
|
|
|
|
|
|
240V |
|
|
2x16 |
|
|
#8 AWG |
|
|
|
|
|
|
|
|
|
1x32 |
|
|
#6 AWG |
|
|
Dream |
|
240V |
|
|
1x16 |
|
|
#8 AWG |
|
||
|
|
|
|
|
|
|
|
2x16 |
|
|
#8 AWG |
|
|
|
|
|
|
|
|
|
1x32 |
|
|
#6 AWG |
|
|
|
Dream HP |
|
|
240V |
|
|
1x16 |
|
|
#8 AWG |
|
|
|
|
|
|
240V |
|
|
2x16 |
|
|
#8 AWG |
|
|
|
|
|
|
|
|
|
1x32 |
|
|
#6 AWG |
|
|
Sojourn HP |
|
240V |
|
|
1x16 |
|
|
#8 AWG |
|
||
|
|
|
|
240V |
|
|
2x16 |
|
|
#8 AWG |
|
|
|
|
|
|
|
|
|
|
1x32 |
|
|
#6 AWG |
|
The power inlet connection is located in the pedestal on the left side of the hot tub, approximately 25" from the front. The front of the hot tub is the section that includes the topside, primary control panel.
To hook-up your hot tub, follow these instructions:
1.Remove the screws holding the equipment access panel to the front of the hot tub cabinet and set the panel aside.
2.Loosen the two screws located on the front of the blue equipment control box and raise the door on the control box on its hinges to allow access to the four wire connection terminal block.
3.Attach 1” rigid non-metallic conduit to the conduit nipple located in the pedestal base on the side of the hot tub and run required conductors through the conduit to the equipment control box.
4.Connect the four/three wires to the equipment system terminal block (TB1) as indicated on the wiring diagram in the back of this manual.
5.Configure jumpers 1 and 2 on the upper right corner of the PC Board to match the circuit size being used for your hot tub. The proper jumper settings can be found on the wiring schematic located on the inside of the Lower Equipment Compartment cover. Use the appropriate Electrical Requirements Chart (shown above) for the proper wire size.
6
2003 Dimension One Spas and @ Home Hot Tubs
Planning Guide and Installation Manual
Owner’s Manual
Hot Tub Cover
Locks on Hot Tub and Cover
Cabinet Care
Filter Use, Removal and Cleaning
GFCI Location
Electrical Disconnect Location
How to Fill and Drain Hot tub
How to Use the Topside Primary
Control
Instructions for your Ultra Pure
Water Management System,
CrystalZone®, or CD
ClearZone™ Ozone Generators &
Water Management Systems
Drain Valve and Hose Bib
Changing Light Lens Cap
Selector Valve Control
Adjusting/Interchanging Jets
Adjusting the NeckFlex™ Jet Pillow and
Interchangeable Jets
Water Care Guide
Automatic Bromine Feeder (Optional)
The Use of the Optional PureVision™
Cartridges
Please check these items before you fill your hot tub with water:
The following section of this manual gives you detailed information on the sizes of both Dimension One and @Home hot tubs. Dimension One hot tubs are listed first, alphabetically by model, followed by @Home hot tubs in the same order.
These specifications include:
•spa shape,
•dimensions,
•electrical requirements,
•water capacity,
•type and number of Hydrotherapy Jets,
•weight,
•type of Water Management System,
•number and type of pumps,
•type of skirt,
•type and number of controls
7
2003 Dimension One Spa s and @ Home Hot Tubs
Planning Guide and Installation Manual
DUE TO MANUFACTURING TOLERANCES THERE COULD BE SOME MINOR DIFFERENCES BETWEEN THE ACTUAL MEASUREMENTS OF YOUR SPA AND THE
Caution
DRAWING BELOW. IF SITE PLANNING IS CRITICAL TO SUCH TOLERANCES, BE SURE TO MEASURE YOUR ACTUAL SPA.
8
2003 Dimension One Spas and @ Home Hot Tubs
Planning Guide and Installation Manual
9
2003 Dimension One Spa s and @ Home Hot Tubs
Planning Guide and Installation Manual
DUE TO MANUFACTURING TOLERANCES THERE COULD BE SOME MINOR DIFFERENCES BETWEEN THE ACTUAL MEASUREMENTS OF YOUR SPA AND THE
Caution
DRAWING BELOW. IF SITE PLANNING IS CRITICAL TO SUCH TOLERANCES, BE SURE TO MEASURE YOUR ACTUAL SPA.
10
2003 Dimension One Spas and @ Home Hot Tubs
Planning Guide and Installation Manual
11
2003 Dimension One Spa s and @ Home Hot Tubs
Planning Guide and Installation Manual
DUE TO MANUFACTURING TOLERANCES THERE COULD BE SOME MINOR DIFFERENCES BETWEEN THE ACTUAL MEASUREMENTS OF YOUR SPA AND THE
Caution
DRAWING BELOW. IF SITE PLANNING IS CRITICAL TO SUCH TOLERANCES, BE SURE TO MEASURE YOUR ACTUAL SPA.
12