Figure 1 DL9118 Overview
- 2 -
Figure 2 Earth Continuity/Insulation Measurement
Figure 3 Voltage measurement using test probes
- 3 -
Figure 4 Voltage, RCD, Zs and line impedance measurement at a mains outlet
Figure 5 Voltage, RCD, Zs, Ze and line impedance measurement at a distribution board
- 4 -
Figure 6 Phase to phase impedance/PSC measurement
Figure 7 Phase rotation
- 5 -
Limited Warranty & Limitation of Liability
DI-LOG Test Equipment guarantees this product to be free from defects in material and workmanship under normal use and service for a period of 2 year. The period of warranty will be effective at the date of purchase.
(c) Copyright 2016 All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from DI-LOG. This also applies to accompanying drawings and diagrams.
Due to a policy of continuous development DI-LOG reserves the right to alter the equipment specification and description outlined in this publication without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract.
- 6 -
Table of Contents
Limited Warranty & Limitation of Liability ............................................... 6
Table of Contents .................................................................................... 7
Introduction ............................................................................................. 9
1 User Notes ........................................................................................ 10
2 Safety Notes ...................................................................................... 11
3 Accessories ....................................................................................... 12
3.1 Standard Accessories ................................................................ 12
3.2 Optional Accessories ................................................................. 12
4 Unit Description ................................................................................ 13
4.1 Identifying parts of the unit ........................................................ 13
4.2 LCD display ............................................................................... 14
5 Using the DL9118 ............................................................................. 16
5.1 Power On ................................................................................... 16
5.2 Battery Health Check ................................................................. 16
5.3 Remote probe ............................................................................ 16
5.4 Continuity Tests ......................................................................... 16
5.5 Insulation Resistance Tests ....................................................... 18
5.6 Voltage Measurement ................................................................ 19
5.7 High Current Earth Loop Impedance / Line Impedance ........... 19
5.8 Non trip Earth Loop Impedance / Line Impedance ................... 21
5.9 Auto RCD Test Sequence .......................................................... 22
5.10 RCD Trip Time Tests ........................................................... 2524
5.11 RCD trip current (Ramp) Tests ................................................ 26
6 Electrical Specifications .................................................................... 28
6.1 Earth Continuity ......................................................................... 28
6.2 Insulation Resistance ................................................................. 28
6.3 Earth Loop Impedance .............................................................. 28
6.4 Line Impedance ......................................................................... 28
6.5 RCD ........................................................................................... 29
6.6 Voltage/Frequency Measurement ............................................. 29
7 Environmental Conditions ................................................................. 30
8 Maintenance ...................................................................................... 31
8.1 Preparing to work on the DL9118. ............................................ 31
8.2 Securing the DL9118 ................................................................. 31
8.3 Cleaning ..................................................................................... 31
8.4 Battery Replacement ................................................................. 32
8.6 Service and Calibration. ............................................................ 33
8.7 Spare Parts. ............................................................................... 34
Appendix A ............................................................................................ 35
- 7 -
Disposal of Old Product
This product has been designed and manufactured with high quality materials and components that can be recycled and reused.
Please familiarise yourself with the appropriate local separate collection system for electrical and electronic products.
Please dispose of this product according to local regulations. Do not dispose of this product along with normal waste material. The correct disposal of this product will help prevent potential negative consequences for the environment and human health.
- 8 -
Introduction
The DL9118 is a hand held, battery powered, multi-function electrical installation test instrument capable of performing a comprehensive range of tests, including:
Earth Continuity @ 200mA Insulation Resistance at 250V, 500V and 1000V Voltage Frequency Phase rotation RCD Trip Time at ½In, In and 5xIn RCD Trip current Non trip Zs and PFC measurement on RCD protected circuits High current Ze and PFC on non RCD protected circuits Phase to neutral impedance and PSC Phase to phase impedance and PSC Power socket wiring polarity
- 9 -
1 User Notes
This instrument and its operating instructions are intended for use by adequately trained personnel.
The following symbols are used in these operating instructions and on the DL9118.
Warning of electrical danger! Indicates instructions must be followed to avoid danger to persons.
Important, follow the documentation! This symbol indicates that the operating instructions must be adhered to in order to avoid danger.
- 10 -
2 Safety Notes
This DL9118 is fully compliant with the requirements of:
BS EN 61010-1: 2010
BS EN 61010-2-30:2010
BS EN 61557 part 1, 2, 3, 4, 6, 7 and 10.
In order to ensure safe operation of this instrument, all notes and warnings in these instructions must be observed at all times.
The DL9118 has been designed to make measurements in a dry environment.
The DL9118 may be used to test circuits with a maximum over-voltage Category III, 300 V AC/DC with reference to earth.
High voltages are present at the probe tips of the DL9118 during insulation resistance measurement. Always hold test probes above the hand guards.
The DL9118 and all associated cables and leads must be checked for signs of damage before equipment is operated.
Prior to any resistance measurement, always ensure that the circuit under test is electrically isolated.
Where safe operation of the DL9118 is no longer possible it should be immediately shut down and secured to prevent accidental operation.
It must be assumed that safe operation is no longer possible:
- if the instrument or leads show visible signs of damage or
- the instrument does not function or
- after long periods of storage under adverse environmental conditions.
If the DL9118 is used in a manner not specified by this document then the protection provided by the equipment may be impaired.
- 11 -