SL101 Manual_SL101 User Manual 05/10/2011 11:06 Page 2

Safety Information
This manual contains information that must be followed for operating the meter
safely and maintaining the meter in a safe operating condition. If this meter is not
used in the manner specified, the protection provided may be impaired.
Warning! Warns of potential danger, refer to the instruction manual to avoid
personal injury or damage to the meter.
Caution! Dangerous voltage. Danger of electrical shock.
Continuous double or reinforced insulation complies with IEC536, class 11
Symbol of conformity, confirms conformity with relevant EU directives. The
meter complies with EMC directives (89/336/EEC). Specifically standards
EN 50081-1 and EN 50082-1 as well as the Low Voltage Directive
(73/23/EEC) described in the standard EN 61010-1.
The meter has been designed in accordance with the safety regulations for
electronic measuring instruments, EN 61010-1, IEC 61010
Before using the meter check for physical damage to the casing in particular
around the connectors. If the case is damaged do not use the meter.
Do not use or store the meter in an environment of high temperature, humidity,
fumes, vapour, gaseous, inflammable and strong magnetic field. The
performance and safety of the user may be compromised is such circumstances.
Replace the battery as soon as the low battery indicator appears. If the battery is
low the meter may give false readings.
Turn the meter power off when not in use. Remove the battery if the meter is not
un use for long periods. Constantly check the battery as it may have leaked. A
leaking battery will damage the meter.
The meter may only be opened buy a qualified service technician for calibration
and repair.
3
SL101 Manual_SL101 User Manual 05/10/2011 11:06 Page 3

Controls, Input and Display
1. Solar power sensor
2. Sunlight sensor input
3. Zero adjust
4. LCD display (data, min/max, hold, W/m² or BTU (ft²*h), low battery range)
5. ON/OFF key
6. W/B - - -Unit (W/m² or BTU/(ft²*h) selection key
7. Range selection key
8. HOLD key
9. MIN/MAX key
10. Backlight key
11. Battery cover & compartment.
4
SL101 Manual_SL101 User Manual 05/10/2011 11:06 Page 4

Function Keys & Operation
• ON/OFF KEY:
Press the ‘ ’ switch to turn the meter on.
• W/B KEY:
Press the ‘W/B’ key to switch from BTU/(ft²*h) to W/m².
• RANGE SELECTION KEY
Press the range key to toggle between ranges, If ‘0L’ is displayed press range
to move to a higher range. If 199.9 is displayed then the reading is beyond the
instrument range.
• HOLD KEY:
Press the ‘HOLD’ key to go into hold mode. ‘HOLD’ appears on the screen to
allow you to read the data, the reading on the display is frozen. Press the key
once again to deactivate it.
• MIN/MAX KEY:
When testing in W/m² or BTU/(ft²*h) press the ‘MIN/MAX’ key to display the
max or min reading value. To turn this mode off hold down the ‘MIN/MAX’ key
for 1 second.
Operation
• Press the power key ‘ ’ to turn the meter on.
• Press the ‘W/B’ key to select W/m² or BTU/(ft²*h) measurement.
• With the sensor cap on, check that the display is zeroed. If the display in not
zeroed, adjust it to zero using the ‘Adj’ trim
• Remove the protection cap from the photo detector and expose it to the light
source in a horizontal position. Read the sunlight (irradiance) value on the
LCD display.
• Wait for values to stabilise on the display. Press ‘HOLD’ key to activate the
data hold function freezing the result on the display (NOTE: If the instrument
displays ‘OL’ the input signal is too high, a higher range must be selected).
3
5
SL101 Manual_SL101 User Manual 05/10/2011 11:06 Page 5

Specification
Operating tem & RH: 5°C to40°C, below 80%RH.
Storage temp & RH: –10°C to60°C, below 70%.
Display: 3–1/2 digits LCD with maximum reading 1999.
Sampling time: Approx 0.25 second.
Resolution: 1W/m²; 1BTU/(ft²*h).
Accuracy: Typically within ± 10W/m²
[±3BTU/(ft²*h) or ±5%, whichever
is the greater in sunlight; Additional
temperature induced error
±0.38W/m²/°C.
Accuracy: > ±3/year.
Over range Display shows ‘OL’.
Range: 1999W/m2, 634BTU/(ft²*h).
Size: 162 (L)*63 (W)*28(H).
Weight (inc. battery): 250g
Battery Replacement
• When the symbol ‘ ‘ is displayed, batteries need replacement. Turn the
meter off.
• Unscrew the battery cover and remove the batteries. Insert new batteries
of the same type (3 x 1.5v AAA alkaline batteries) observing the correct
polarity, replace the battery cover and reposition the protective holster.
11
6
SL101 Manual_SL101 User Manual 05/10/2011 11:06 Page 6

Warning
Do not attempt to repair or service your meter unless you are qualified to do so
and have the relevant calibration, performance test and service information.
To avoid electrical shock or damage to the meter do not get water inside the
case. Periodically wipe the case with a soft damp cloth and mild detergent.
Do not use chemical solvent.
Accessories
•User manual.
•3 x 1.5v AAA alkaline batteries.
•Carry case.
7
SL101 Manual_SL101 User Manual 05/10/2011 11:06 Page 7

24 Month Warranty
Di-Log Solar instruments are subject to stringent quality controls. If in the course
of normal daily use a fault occurs we will provide a 24 month warranty (only
valid with invoice).
Faults in manufacturer and materials defect will be rectified by us free of charge,
provided the instrument has not been tampered with and returned to us
unopened.
Damage due to dropping, abuse or misuse is not covered by the warranty.
Outside the warranty period we offer a full repair and re-calibration service.