Di-LOG DL6505 Operating Manual

Page 1
DL6505
200A AC MINI
CLAMP-ON METER
operating manual
EN
61010-1
CAT II
600V
Page 2
This manual contains information that must be followed for operating the meter safely and maintaining the meter in a safe operating condition. If this meter is not used in the manner specied, the protection provided may be impaired.
Warning! Warns of potential danger, refer
to the instruction manual to avoid personal injury or damage to the meter.
Caution! Dangerous voltage. Danger of
electrical shock
Continuous double or reinforced insulation
complies with IEC536, class 11
Symbol of conformity, conrms conformity with
relevant EU directives. The meter complies with EMC directives (89/336/EEC). Specically stand­ards EN 50081-1 and EN 50082-1 as well as the Low Voltage Directive (73/23/EEC) described in the standard EN 61010-1.
The meter has been designed in accordance with the safety regulations for electronic measuring instruments, EN 61010-1, IEC 61010
Voltages above 75V DC or 50V AC may constitute a serious shock hazard.
Before using the meter casing check for physical damage to the casing in particular around the connectors. If the case is damaged do not use the meter.
Safety Information
Page 3
Check the test leads for damaged insulation or expose metal. Check the leads for continuity. Replace damaged leads with identical model or specication before using the meter.
Where applicable use GS38 approved leads (not supplied) these are available from Di-Log. When using test leads keep ngers behind the nger guards.
Do not apply more than the rated voltage, as marked on the meter between the terminals or between any terminal and ground.
Before making a measurement ensure that the rotary switch is set to the appropriate range. Do not turn the rotary switch whilst making a measurement.
Use the appropriate terminals, function and range for your measurements. If the value to be measured is not known use the maximum measurement position and reduce the range step by step until a satisfactory reading is obtained.
Do not use or store the meter in an environment of high temperature, humidity, fumes, vapour, gaseous, inammable and strong magnetic eld. The performance and safety of the use may be compromised in such circumstances.
Disconnect circuit power and discharge all high voltage capacitors before testing resistance, continuity, diodes, capacitance or current.
Page 4
Safety Information
Before measuring current check the meters fuses and turn off power to the circuit before connecting the meter to the circuit.
Replace the battery as soon as the low battery indicator appears. If the battery is low the meter may give false readings.
Turn the meter power off when not in use,. Remove the battery if the meter is in use for a long period. Constantly check the battery as it may have leaked. A leaking battery will damage the meter.
The meter may only be opened by a qualied service technician for calibration and repair.
Page 5
• 3-1/2 digit (2000 count) LCD display
• High resolution to 10mA AC
• Built-in non-contact AC voltage detector plus ashlight
• MAX Hold and Data Hold
• Auto power off
• (18mm) Jaw opening
Page 6
Specications
Display:
3-1/2 (2000 count) Digit LCD
Polarity: Minus sign ( - ) indicates negative polarity
Overload indication: “OL” displayed on the LCD
DCA zero adjust: One touch zero key
Display rate: 2 readings/second, nominal
Battery: Two 1.5V AAA batteries
Low Battery indication: “BATT” displayed on the LCD
Auto OFF: approx. 7 minutes
Operating conditions:
32˚F to 86˚F (0˚C to 30˚C) 90%RH; 86˚F to 104˚F (30˚C to 40˚C) 75%RH; 104˚F to 122˚F (40˚C to 50˚C) 45%RH
Storage conditions:
- 14˚F to 140˚F (-30˚C to 60˚C); <
90% Relative Humidity
Altitude: Operate at less than 3000 meters
Weight: 175g including battery
Dimensions: 164 x 65 x 32mm
Jaw opening: 18mm
Standards: IEC 1010, Category II 600V
Page 7
6
2
4
1
5
7
Range Specications
Function Range Resolution Accuracy (of reading)
AC Current (50/60Hz) 2A 1mA
80A 200mA ±(3.0% + 8 digits)
Non-Contact AC Voltage 100VAC to 600VAC 50/60Hz
3
9
8
Page 8
Specications
Meter Description
1. Current sensor jaw
2. Torch button
3. Rotary function switch
4. Data HOLD key
5. LCD display
6. Clamp trigger
7. MAX HOLD key
8. Non-contact AC voltage indicator light
9. Non-contact AC voltage detector probe tip
Function Maximum Inputs
AC Current 200A
Input Limits
Page 9
1. Set the Function switch to the ACA range.
2. Press the jaw trigger and clamp around, fully enclosing a single conductor. Do not allow a gap between the two halves of the jaw. Refer to the diagram at right for the correct way to enclose a single conductor.
3. Read the ACA value on the LCD.
wrong correct
Page 10
Non-Contact AC Voltage Meassurements
Warning:
RISK OF ELETROCUTION. BEFORE USE, ALWAYS TEST
THE VOLTAGE DETECTOR ON A KNOWN LIVE CIRCUIT
TO VERIFY PROPER OPERARTION.
1. Touch the probe tip to the hot conductor or insert into the hot side of the electrical outlet.
2. If AC voltage is present, the detector light will illuminate.
Note: The conductors in electrical cord sets are often twisted. For best results, rub the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor.
Note:
The detector is designed with high sensitivity. Static electricity or other sources of energy may randomly trip the sensor. This is normal operation.
Page 11
Torch
Press and hold the top button to turn the torch on. Release the button to turn the torch off.
Data Hold
To freeze the current reading on the LCD, press the “Hold Backlight” key. The word HOLD will appear on the LCD while the meter is in the Data Hold mode. To release the Data Hold function and return the meter to normal operation, press the “Hold Backlight” key again. The word HOLD will switch off.
MAX Hold
To hold the highest reading on the LCD, press the MAX hold button. The MAX hold button is located on the left side of the meter (bottom button). The meter reading will not change as readings change, rather it will only display the highest reading encountered since the MAX hold button was pressed. Press the MAX hold button again to return to normal operation.
Auto Power Off
The auto off feature will turn the meter off after 7 minutes.
Battery Replacement
1. When the low battery symbol appears on the LCD the batteries must be replaced.
2. Power down and remove the rear battery compartment Phillips screw.
3. Lift off the battery compartment cover and replace the two 1.5V AAA cells.
4. Replace compartment cover and secure the screw..
Operations
Page 12
Warranty & Maintenance
Di-Log Test Equipment
28 Wheel Forge Way, Trafford Park, Manchester
M17 1EH, UK
tel: + 44 161 87 7 0322 fax: + 44 161 877 1614
email: sales@dilog.co.uk website: www.dilog.co.uk
24 Month Warranty
Di-Log instruments are subject to stringent quality controls. If in the course of normal daily use a fault occurs we will provide a 24 month warranty (only valid with invoice).
Faults in manufacture and materials defect will be rectied by us free of charge, provided the instrument has not been tampered with and returned to us unopened.
Damage due to dropping abuse or misuse is not covered by the warranty.
Outside the warranty period we offer a full repair and re-calibration service.
Maintenance
WARNING Do not attempt to repair or service your meter
unless you are qualied to do so and have the relevant calibration, performance test and service information. To avoid electrical shock or damage to the meter do not get water inside the case.
Periodically wipe the case with a damp cloth and mild detergent. Do not use chemical solvent.
Clean the input terminals with cotton bud, as dirt or moisture in the terminals can affect readings.
EN
61010-1
CAT II
600V