Di-log DL107 User guide

Page 1
DL107 - Voltage Detector
Instruction Manual
24 - 1000V AC Voltage Detector with High/Low Sensitivity
Page 2
Di-LOG
...measurably better
DL107 Operating Manual
Contents
V. Display and Controls 7
3. Warranty Information 10
1
Page 3
Di-LOG
...measurably better
Certicate of conformity
As the manufacturer of the instrument listed below, we declare under our sole responsibility that the product:
Di-LOG DL107 - Voltage Detector
to which this declaration relates is in conformity with the relevant clauses of the following standards:
EN 61010-1 EN 61010-2-030 EN 61326-1 EN 61326-2-2 LVD & EMC
The performance of this instrument
operates within its specication when
used under the conditions in the above safety and EMC standards.
The product identied above conforms to the requirements of council directive
89/336/EEC and 73/23 EEC.
2
Page 4
Di-LOG
...measurably better
DL107 Operating Manual
I. Overview
The DL107 is a non-contact voltage detector
with a built-in ashlight and audible/optical
alarm function. The CAT IV 1000V safety class ensures user safety, making it an essential tool for the electrical industry.
Low voltage mode (24V AC - 1000V AC)
Suitable for testing low-voltage motors (< 90V) , audio systems, arc welding machines, cables with a thick insulation layer, and other weak electromagnetic AC signals.
High voltage mode (90V AC - 1000V AC)
For detecting domestic electric supply and three-phase systems. For example, power distribution units, electrical panels, and electrical appliances.
II. Safety Notices
1. Please carefully read and fully understand the warnings and operating instructions before use. If the instrument is used in a
manner not specied by the manufacturer,
the protection provided by the instrument may be impaired.
2. Please test the detector on a known live source within the rated AC voltage range before use.
3. If the detector appears damaged or is not working properly, stop using it immediately.
4. Do not detect voltage higher than 1000V.
5. Use caution when working with voltages above AC 30Vr.m.s, 42Vpeak or DC 60V. Such voltages pose a shock hazard. Clean the tester casing with a damp cloth and mild detergent. Do not use abrasives or solvents!
3
Page 5
Di-LOG
...measurably better
II. Safety Notices (continued)
6. There may still be voltage even when no
audible/optical alarm is on.
7. The insulation type, conductor thickness, distance from voltage source, shielded conductors, other cables, socket design,
and other factors may adversely a󰀨ect test
result. If there are any uncertainties, please use other methods to verify the voltage.
8. Do not assume neutral or earth wire is safe to touch. Incorrect or poorly connected circuits may cause conductors to be charged.
9. When low battery indication appears, please replace the batteries.
10. When using the detector, please keep
ngers behind the nger guard before the
clear detector head and do not cover.
11. Comply with local and national safety regulations and requirements.
12. The detector will not detect any voltage if: a. The conductor is shielded. b. The operator is not in contact with the
ground or isolated from an e󰀨ective grounding
point. c. The voltage is DC.
13. The detector may not detect any voltage if: a. The operator does not hold the detector. b. The operator is wearing gloves. c. The conductor under test is partially buried or in earthed metal conduit.
d. The magnetic eld generated by the
voltage source is blocked, suppressed or interfered with. e. The frequency of the voltage being detected is not a perfect sine wave and may be distorted by harmonics f. The detector is used outside of the
operating specications (see Technical Specications for details)
4
Page 6
Di-LOG
DL10x Series Voltage Detector Specifi cation
DL107 DL108
Detection voltage range
Low: 24V - 1000V AC
High: 90V - 1000V AC
Frequency range 50Hz/60Hz
Operation mode Automatic Indication
Vibration mode N /A
LED fl ashlight
Audible and visual
indication
Auto power o About 5 minutes
Low battery indication 2.4V
IP rating N/A IP67
Drop tested 1M 2M
Safety rating CAT IV 1000V Double Insulated
Operating temperature 0°C - 40°C
Storage temperature -20°C - 50°C
Relative humidity 80% non-condensing
Dimensions
150mm x 18mm x
23mm
160.5mm x 21.5 mm x 25mm
Weight (net) 50g 72g
Power supply 2 x 1.5V (RO3) AAA (supplied)
...measurably better
DL107 Operating Manual
III. Instrument Symbols
Symbols displayed on the instrument and in the instruction manual:
Warning! Warns of potential danger, and to comply with the instruction manual.
Caution! Dangerous voltage, potential risk of electrical shock.
Continuous double or reinforced insulation complies to IEC 536, Class II
Symbol of conformity, conrms
conformity with relevant EU directives. The instrument complies
with the EMC Directive (89/336/ EEC) specically standards
EN 50081-1 and EN 50082-1, as well as the Low Voltage Directive
(73/23/EEC) described in the
standard EN 61010-1.
5
Page 7
Di-LOG
...measurably better
IV. DL10x Series Specication
DL10x Series Voltage Detector Specifi cation
Detection voltage range
Frequency range 50Hz/60Hz
Operation mode Automatic Indication
Vibration mode N /A
LED fl ashlight
Audible and visual
indication
Auto power o About 5 minutes
Low battery indication 2.4V
IP rating N/A IP67
Drop tested 1M 2M
Safety rating CAT IV 1000V Double Insulated
Operating temperature 0°C - 40°C
Storage temperature -20°C - 50°C
Relative humidity 80% non-condensing
Dimensions
Weight (net) 50g 72g
Power supply 2 x 1.5V (RO3) AAA (supplied)
DL107 DL108
Low: 24V - 1000V AC
High: 90V - 1000V AC
150mm x 18mm x
23mm
160.5mm x 21.5 mm
x 25mm
6
Page 8
Di-LOG
...measurably better
DL107 Operating Manual
V. Display and Controls
1. Non-contact voltage sensor
2. LED Flashlight
3. LED for Voltage Indication
4. High/Low mode status indicator light
5. Power button
6. Flashlight On/O󰀨 button
7. Pocket clip
8. Battery case cover
1. Operating Instructions
Turning the detector on
With a short press of the power button, the buzzer will beep twice and the red indicator display on the panel will illuminate, indicating that the detector is on and ready for use. The default AC voltage detection range is set to high (90 - 1000V).
Turning the ashlight on/o󰀨
A short press of the ashlight button will turn the ashlight on/o󰀨. The ashlight will automatically turn o󰀨 when the detector
is not used for 5 minutes.
Note: Please unplug other electrical devices connected to the socket before detection.
7
Page 9
Di-LOG
...measurably better
AC voltage detection
Place the sensor head near the test object or the power socket with AC voltage. When AC voltage is detected, the red LED located within the sensor
head will ash and an audible buzzer will
sound. Audible buzzer and sensing LED frequencies increase when detector gets closer to the test object.
Detection range selection
a) When the detector is switched on, the default setting is pre programmed to high voltage mode, with a detection range of 90-1000V. The red indicator light on the display panel will illuminate.
b) With an additional short press of the power button, the red indicator light will switch to green, and the device will switch to low voltage mode, with range of 24-1000V.
In low voltage mode, the detector is more
sensitive to electrical interference/noise.
Please only use the low voltage mode
when detecting weak electromagnetic eld.
Auto power o󰀨
The detector will auto power o󰀨 when it is
not used for 5 minutes.
Turning the detector o󰀨 manually
A long press of the power button for 2
seconds will turn the detector o󰀨.
Low battery indication
When the battery voltage is lower than
2.4V, the detector will automatically shut down.
8
Page 10
Di-LOG
...measurably better
DL107 Operating Manual
2. Battery Replacement
1. Hold the detector with one hand, use the thumb of your other hand to press down on the battery compartment latch, and pull the end of the detector.
2. Pull out the end of the detector in the direction shown in the above picture and replace the batteries according to the polarity indicated on the instrument.
Re-t the battery cover once complete
making sure the latch clicks back into place.
Do not mix old and new batteries. Do not mix alkaline, standard (Zinc Carbon), or rechargeable (Ni-Cad, Ni-Mh, etc) batteries.
9
Page 11
Di-LOG
...measurably better
3. 24 Month Warranty
Di-LOG instruments are subject to strin­gent quality controls. If in the course of normal daily use a fault occurs we provide a 24 month warranty (only valid with proof of purchase). Faults in manufacture and
material defects will be rectied by us free
of charge, provided the instrument has not been tampered with and returned to us unopened. Damage due to droppin g, abuse or misuse are not covered by the warranty.
Di-LOG Ltd
Unit 28 Wheel Forge Way
Tra󰀨ord Park
Manchester M17 1EH UK Tel:+44 (0)161 877 0322 Email: sales@dilog.co.uk Website: www.dilog.co.uk
10
Page 12
Loading...