No part of this publication may be copied, distributed, transmitted, transcribed, stored in a
retri eval syst em , or t ran sl ated int o any huma n or compu te r lan gu ag e with ou t t he pr io r wri tte n
permission of Digium, Inc.
Digium, Inc. has made every effort to ensure that the instructions contained in this document
are ade q u a te an d error free. The manu facture r w i ll, if ne c es s ary , explai n issues w h ic h m ay
not be covered by this documentation. The manufacturer’s liability for any errors in the
docume nts is limi ted to the correctio n of errors and the aforementioned advis ory services.
This doc ument has been prepar ed for us e by profe ssiona l and pr operly tr ained personn el,
and the cus to m er as su m es full respon si bi lity when us in g it.
Adobe and Acrobat are registered trademarks, and Acrobat Reader is a trademark of Adobe
Systems Incorporated.
Asteri sk and D igi um a r e re gi ster e d tr ad emar ks and Ast eri sk B usi ne ss Ed it i on, A st eri sk NOW,
AsteriskGUI, and Asterisk Appliance are trademarks of Digium, Inc.
Any other trademarks mentioned in the document are the property of their respective owners.
Release 1.0Digium, Inc.Page 2
Safety Certificati on and Agency Approvals
Safety:
UL 60950-1:2003, First Edition
CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003
IEC 60950-1:2001 First Edition
EN 60950
AS/NZS 60950
Note: Finland, Norway and Sweden require that equipment using this
product must be located in a Restric ted Access Location (RAL).
Telecom:
FCC Part 68, ANSI/ITA-968-A, Including Amendment A1 and A2
Industry Canada CS-03
AS/ACIF S016: 2001
AS/ACIF S038: 2001
ICASA (TE405P/TE407P/TE410P/TE412P)
RosTest
TBR4 November 1995 as amended by TBR4/A1 December 1997
TBR12 December 1993
TBR13 January 1996
Emissions:
Note: Shielded T1/E1/J1 cables are required for compliance purp oses.
47 CFR Part 15, Subpart B / 47 CFR Part 15, Subpart B, Class B
EN 55022:1998 Class B / EN 55022:1998 Class B Radiated and
Conducted
EN 55024:1998 / IEC 61000
Release 1.0Digium, Inc.Page 3
Immunity:
EN55024 ITE, EN61000
Federal Communications Commission Part 68
This equipment complies with Part 68 of the FCC rules and the
requirements adopted by the ACTA. On the back of the TE 400 Series
printed circuit board is a label tha t contains, among other information, a
product identifier in the format US:AAAEQ##TXXXX. If requested, this
number must be provided to the telephone compa ny.
A plug and jack used to connect this equipment to the premi ses wiring
and telephone network must comply with the applicable FCC Part 68
rules and requirements adopted by the ACTA.
If the TE 400 Series causes harm to the telephone network, the telephone
company may notify you in advance that temporary discontinuance of
service may be required. But if advance notice is not practical, the
telephone company will noti fy you as soon as possible. Also, you will be
advised of your right to file a complaint with the FCC if you believe it is
necessary.
The telephone company may make changes in its facilities, equipment,
operations or procedures that could a ffect the operation of the equipment.
If this happens, the telephone company will provide advance notice in
order for you to make necessary modifications to maintain uninterrupted
service.
If you experience problems with the TE 400 Series, contact Digium, Inc.
(+1.256.428.6161) for repair and/or warranty information. If the
equipment is causing harm to the telephone network, the telephone
Release 1.0Digium, Inc.Page 4
company may request that you disconnect the equipment until the
problem is resolved.
FCC Part 15
This device complies with part 15 of FCC rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interferen ce, and (2) T h is dev ice mu s t accep t any in terference receiv ed,
including interf erence that may cause undesired operation.
Industry Canada Compliance Information
Notice: The Industry Canada label applied to the product (identified by
the Industry Canada logo or the "IC:" in f ront of the certification/
registration number) indicates that the Industry Canada technical
specifications were met.
Release 1.0Digium, Inc.Page 5
Introduction to TE 400 Series Documentation
This manual is a user guide for Digium’s TE 400 Series cards. The
Digium TE 400 Series cards are a T1/E1 capable card series created for
voice and data. The car d s in this se ri es are as follo w s:
The TE400 Series user’s guide is organized in the following manner:
Chapter/
Appendix
1
2
3
4
A
B
C
TitleDescription
OverviewIdentifies the features of the card you received. This
chapter covers applications and uses of the TE 40 0
Series cards i n the real world.
Card InstallationProvides instructions for installing the card in your
PC, acquiring correct drivers, and checking device
compatibility.
ConfigurationProvides examples for configuring dial plan options.
Troublesh ootingExpla ins resolutio ns to common problems and
frequentl y as ked questions per taining to card
installation and usage.
Pin AssignmentsLists the connectors and pin assignments .
SpecificationsDetails card specifications.
Glossary and
Acronyms
Defines terms related to this product.
Release 1.0Digium, Inc.Page 7
Symbol Definitions
Caution stat emen ts in dicate a c onditio n whe r e d amage to t he un it o r
its configuration could occur if operational procedures are not
followed. To reduce the risk of damage or injury, follow all steps or
procedures as instructed.
The ESD sym b o l in d i ca t es electrostat i c sen s i ti ve de vi ce s . O b serve
prec autions for handling devi ces. Wear a proper ly grounded
electrostatic discha rge (ESD) wrist strap while handling the device.
The Electrical Hazard Symbol indicates a possibility of electrical
shock when operat ing this unit in certain situations. To reduce the
risk of damage or injury, fol low all steps or proc edures as
instructed.
Release 1.0Digium, Inc.Page 8
User Cautions
Servicing.
Do not attempt to service this card unless specifically instructed to do
so. Do not attempt to remove the card from your equipment while
power is present. Refe r ser vicing to qualified service personnel.
Water and Moisture.
Do not spill liquids on this unit. Do not operate this equipment in a
wet environme nt.
Heat.
Do not operate or store this product near heat sources such as
radiators, air ducts, areas subject to direct, intense sunlight, or other
products that produce heat.
Static Electricity.
To reduce the risk of damaging the unit or your equipment, do not
attempt to open the enclosur e or gain acc es s to areas where you ar e
not instructed to do so. Refer servicing to qualified service personnel.
The Digium TE 400 Series cards are a T1/E1 capable card series created
for voice and data. They support industry standard protocols, including
Robbed Bit Signaling, E&M, Primary Rate ISDN (PRI), and several data
modes (PPP, HDLC, Cisco HDLC and frame relay). The TE400 Series
are capable of running in E1, T1, or J1 modes. They are also capable of
DACSing channels f rom one span to another . The TE 400 S eries are ideal
for connecting phones to a channel bank, connec ting to your T1/E1
switch, or connecting to a legacy PBX.
This manual is for use with the TE420/TE420B PCI Express car d, as well
as the 5 volt TE405P/407P and the 3.3 volt TE410P/412P Quad T1/E1
PCI cards. These cards are identified collectively as the TE 400 Series
cards throughout this manual.
Designed to be fully compatible with existing software applications and
integrate fully with Asteris k Open Source PBX/I VR platform, the TE 400
Series cards allow many advanced call fea tures.
The TE 400 Series cards can be used to connect your Asterisk machine to
the PSTN world, your channel bank, or even another PBX. This is
accomplished via a T1/E1 interface. The cards allow Asterisk software to
connect to your network, creating a professional telephony environment.
Figure 2 shows an example of the card’s primary application.
Release 1.0Digium, Inc.Page 15
CLEC
Chapter 1: Overview
Asterisk
Server
TE4xx
Figure 1: Sample Legacy Phone Application
T1
T1
T1
Channel
Bank
PRI
Legacy
PBX
Legacy
Phones
Legacy
PBX
Analog
Phones
Release 1.0Digium, Inc.Page 16
CLEC
Asterisk
Server
TE4xx
Analog
Phones
PRI
T1
T1
T1
Channel Bank
Channel Bank
Channel Bank
Chapter 1: Overview
Figure 2: Sample Channel Bank Application
Release 1.0Digium, Inc.Page 17
Chapter 1: Overview
CLEC
ASTERISK
SERVER
TE4xx
Switch
Eth
LAN
IP
Phones
PRI
T1
PRI
T1
Figure 3: Sample IP Phone Application