Digium TE420B, TE420, TE405P, TE407P, TE412P User Manual

...
TE400 Series
TE420B/TE420/412P/410P/407P/405P
User Manual
Release 1.0
150 West Park Loop, Suite 100
Digium, Inc.
Huntsvil le, AL 35806
United States
Main Number: 1.256. 428.6000
Tech Support : 1.256.428.6161
U.S. Toll Free: 1.877.546.8963
Sales: 1.256.428.6262
www.digium.com www.asterisk.org
www.asterisknow.org
© Digium, Inc. 2007 All rights reserved.
No part of this publication may be copied, distributed, transmitted, transcribed, stored in a retri eval syst em , or t ran sl ated int o any huma n or compu te r lan gu ag e with ou t t he pr io r wri tte n permission of Digium, Inc.
Digium, Inc. has made every effort to ensure that the instructions contained in this document are ade q u a te an d error free. The manu facture r w i ll, if ne c es s ary , explai n issues w h ic h m ay not be covered by this documentation. The manufacturer’s liability for any errors in the docume nts is limi ted to the correctio n of errors and the aforementioned advis ory services.
This doc ument has been prepar ed for us e by profe ssiona l and pr operly tr ained personn el, and the cus to m er as su m es full respon si bi lity when us in g it.
Adobe and Acrobat are registered trademarks, and Acrobat Reader is a trademark of Adobe Systems Incorporated.
Asteri sk and D igi um a r e re gi ster e d tr ad emar ks and Ast eri sk B usi ne ss Ed it i on, A st eri sk NOW, AsteriskGUI, and Asterisk Appliance are trademarks of Digium, Inc.
Any other trademarks mentioned in the document are the property of their respective owners.
Release 1.0 Digium, Inc. Page 2
Safety Certificati on and Agency Approvals
Safety:
UL 60950-1:2003, First Edition CSA C22.2 No. 60950-1-03 1st Ed. April 1, 2003 IEC 60950-1:2001 First Edition EN 60950 AS/NZS 60950
Note: Finland, Norway and Sweden require that equipment using this product must be located in a Restric ted Access Location (RAL).
Telecom:
FCC Part 68, ANSI/ITA-968-A, Including Amendment A1 and A2 Industry Canada CS-03 AS/ACIF S016: 2001 AS/ACIF S038: 2001 ICASA (TE405P/TE407P/TE410P/TE412P) RosTest TBR4 November 1995 as amended by TBR4/A1 December 1997 TBR12 December 1993 TBR13 January 1996
Emissions:
Note: Shielded T1/E1/J1 cables are required for compliance purp oses.
47 CFR Part 15, Subpart B / 47 CFR Part 15, Subpart B, Class B EN 55022:1998 Class B / EN 55022:1998 Class B Radiated and Conducted EN 55024:1998 / IEC 61000
Release 1.0 Digium, Inc. Page 3
Immunity:
EN55024 ITE, EN61000
Federal Communications Commission Part 68
This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. On the back of the TE 400 Series printed circuit board is a label tha t contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If requested, this number must be provided to the telephone compa ny.
A plug and jack used to connect this equipment to the premi ses wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA.
If the TE 400 Series causes harm to the telephone network, the telephone company may notify you in advance that temporary discontinuance of service may be required. But if advance notice is not practical, the telephone company will noti fy you as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations or procedures that could a ffect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service.
If you experience problems with the TE 400 Series, contact Digium, Inc. (+1.256.428.6161) for repair and/or warranty information. If the equipment is causing harm to the telephone network, the telephone
Release 1.0 Digium, Inc. Page 4
company may request that you disconnect the equipment until the problem is resolved.
FCC Part 15
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interferen ce, and (2) T h is dev ice mu s t accep t any in terference receiv ed, including interf erence that may cause undesired operation.
Industry Canada Compliance Information
Notice: The Industry Canada label applied to the product (identified by the Industry Canada logo or the "IC:" in f ront of the certification/ registration number) indicates that the Industry Canada technical specifications were met.
Release 1.0 Digium, Inc. Page 5
Introduction to TE 400 Series Documentation
This manual is a user guide for Digium’s TE 400 Series cards. The Digium TE 400 Series cards are a T1/E1 capable card series created for voice and data. The car d s in this se ri es are as follo w s:
Table 1: TE400 Series Cards
Model Features Type
TE420B TE420 TE412P TE410P TE407P TE405P
Release 1.0 Digium, Inc. Page 6
3.3 volt, 4 Ports, Echo Cancellation
3.3 volt, 4 Ports
3.3 volt, 4 Ports, Echo Cancellation
3.3 volt, 4 Ports
5.0 volt, 4 Ports, Echo Cancellation
5.0 volt, 4 Ports
PCI Express PCI Express PCI 2.2 PCI 2.2 PCI 2.2 PCI 2.2
Document Organization
The TE400 Series user’s guide is organized in the following manner:
Chapter/
Appendix
1
2
3 4
A B C
Title Description
Overview Identifies the features of the card you received. This
chapter covers applications and uses of the TE 40 0 Series cards i n the real world.
Card Installation Provides instructions for installing the card in your
PC, acquiring correct drivers, and checking device compatibility.
Configuration Provides examples for configuring dial plan options.
Troublesh ooting Expla ins resolutio ns to common problems and
frequentl y as ked questions per taining to card installation and usage.
Pin Assignments Lists the connectors and pin assignments .
Specifications Details card specifications.
Glossary and Acronyms
Defines terms related to this product.
Release 1.0 Digium, Inc. Page 7
Symbol Definitions
Caution stat emen ts in dicate a c onditio n whe r e d amage to t he un it o r its configuration could occur if operational procedures are not followed. To reduce the risk of damage or injury, follow all steps or procedures as instructed.
The ESD sym b o l in d i ca t es electrostat i c sen s i ti ve de vi ce s . O b serve prec autions for handling devi ces. Wear a proper ly grounded electrostatic discha rge (ESD) wrist strap while handling the device.
The Electrical Hazard Symbol indicates a possibility of electrical shock when operat ing this unit in certain situations. To reduce the risk of damage or injury, fol low all steps or proc edures as instructed.
Release 1.0 Digium, Inc. Page 8
User Cautions
Servicing.
Do not attempt to service this card unless specifically instructed to do so. Do not attempt to remove the card from your equipment while power is present. Refe r ser vicing to qualified service personnel.
Water and Moisture. Do not spill liquids on this unit. Do not operate this equipment in a wet environme nt.
Heat. Do not operate or store this product near heat sources such as radiators, air ducts, areas subject to direct, intense sunlight, or other products that produce heat.
Static Electricity.
To reduce the risk of damaging the unit or your equipment, do not attempt to open the enclosur e or gain acc es s to areas where you ar e not instructed to do so. Refer servicing to qualified service personnel.
Save these instructions for future reference.
Important Safety Instructions
Release 1.0 Digium, Inc. Page 9
TABLE OF CONTENTS
Chapter 1
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
What is Asterisk?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Chapter 2
Card Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Unpacking the Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Identifying Communication Ports . . . . . . . . . . . . . . . . . . . . . . . . . .22
T1/E1 Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Identifying Multiple Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Connecting Timing Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
PCI Slot Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Software Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Chapter 3
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Configuring T1/E1 Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Testing Your configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Chapter 4
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
Appendix A
Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Release 1.0 Digium, Inc. Page 10
Table Of Contents
Appendix B
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 0
Appendix C
Glossary and Acronyms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 2
Release 1.0 Digium, Inc. Page 11
List of Figures
Figure 1: Sample Legacy Phone Application . . . . . . . . . . . . . .16
Figure 2: Sample Channel Bank Application . . . . . . . . . . . . . .17
Figure 3: Sample IP Phone Application . . . . . . . . . . . . . . . . . .18
Figure 4: TE405P Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Figure 5: TE420 Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Figure 6: T1/E1 Jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Figure 7: Ident Wheel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Figure 8: Timing Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Figure 9: Motherboard PCI Slots . . . . . . . . . . . . . . . . . . . . . . .27
Figure 10: Insert the Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Figure 11: dmesg Screen Capture . . . . . . . . . . . . . . . . . . . . . . . 41
Release 1.0 Digium, Inc. Page 12
List of Tab le s
Table 1: TE400 Series Cards . . . . . . . . . . . . . . . . . . . . . . . 6
Table A-1: RJ45 Telco Port Connector . . . . . . . . . . . . . . . . . . . .49
Table B-2: Maximum Power Consumption . . . . . . . . . . . . . . . . .51
Release 1.0 Digium, Inc. Page 13

Chapter 1 Overview

The Digium TE 400 Series cards are a T1/E1 capable card series created for voice and data. They support industry standard protocols, including Robbed Bit Signaling, E&M, Primary Rate ISDN (PRI), and several data modes (PPP, HDLC, Cisco HDLC and frame relay). The TE400 Series are capable of running in E1, T1, or J1 modes. They are also capable of DACSing channels f rom one span to another . The TE 400 S eries are ideal for connecting phones to a channel bank, connec ting to your T1/E1 switch, or connecting to a legacy PBX.
This manual is for use with the TE420/TE420B PCI Express car d, as well as the 5 volt TE405P/407P and the 3.3 volt TE410P/412P Quad T1/E1 PCI cards. These cards are identified collectively as the TE 400 Series cards throughout this manual.
Designed to be fully compatible with existing software applications and integrate fully with Asteris k Open Source PBX/I VR platform, the TE 400 Series cards allow many advanced call fea tures.
Data Modes:
Cisco HDLCHDLCPPPMultilink PPPFrame Relay
Release 1.0 Digium, Inc. Page 14
Voice Modes:
PRI CPE and PRI NET
NI1NI2EuroISDN4ESS (AT&T)5ESS (Lucent)DMS100
E&M
WinkFeature Group BFeature Group D
FXO and FXS
Ground StartLoop StartLoop Start with Disconn ect Detect
Chapter 1: Overview
The TE 400 Series cards can be used to connect your Asterisk machine to the PSTN world, your channel bank, or even another PBX. This is accomplished via a T1/E1 interface. The cards allow Asterisk software to connect to your network, creating a professional telephony environment. Figure 2 shows an example of the card’s primary application.
Release 1.0 Digium, Inc. Page 15
CLEC
Chapter 1: Overview
Asterisk Server
TE4xx
Figure 1: Sample Legacy Phone Application
T1
T1
T1
Channel
Bank
PRI
Legacy PBX
Legacy Phones
Legacy PBX
Analog Phones
Release 1.0 Digium, Inc. Page 16
CLEC
Asterisk Server
TE4xx
Analog Phones
PRI
T1
T1
T1
Channel Bank
Channel Bank
Channel Bank
Chapter 1: Overview
Figure 2: Sample Channel Bank Application
Release 1.0 Digium, Inc. Page 17
Chapter 1: Overview
CLEC
ASTERISK SERVER
TE4xx
Switch
Eth
LAN
IP Phones
PRI
T1
PRI
T1
Figure 3: Sample IP Phone Application
Release 1.0 Digium, Inc. Page 18
Chapter 1: Overview

What is Asterisk?

Asterisk is the first open -source telephony platform. Since it runs on Linux, it inherits all of the power and stability of that operating system. The name Asteri sk is derived from the all-inclusive “wildcard” symbol i n UNIX. It is representative of the wide range of opportunities it opens for developers worldwide to create solutions which would otherwise be cost­prohibitive.
Asterisk allows you to create a PBX solution that rivals the features and functionality of traditi ona l telephony swi tc hes. Current P BX soluti ons are expensive and proprieta ry. International companies are discover ing that Asterisk is cost ef fectiv e, low mainte nanc e, and flexibl e enough to handle all of their voice and data networking. Combined with Digium hardware and a common PC, anyone can replace an existing switch or complement a PBX by adding VoIP, voicemail, confer encing, and many other capabilities . Aste risk will integrate with most standards- based IP telephone handsets and softwa re. Analog phones and ADSI-screen phones are also supported.
Release 1.0 Digium, Inc. Page 19

Chapter 2 Card Installation

This chapter provides the following information:
Unpacking the Card on page 21Identifyi ng C om m un ic a tion Por ts on page 22T1/E1 Selection on page 24Identifying Multiple Cards on page 24Connecting Timing Cables on page 25PCI Slot Compatibility on page 27Hardware Installat ion on page 29Software Installation on page 30
Note: The TE400 Series card installation instructions are written so that they will apply to any card in the series. Examples and card specific inf ormation are included as need ed .
Release 1.0 Digium, Inc. Page 20
Chapte r 2: C ar d In st a lla tion

Unpacking the Card

When you unpack your card, carefully inspect it for any damage that may have occurred in shipment. If damage is suspected, file a claim with the carrier and contact your reseller from which the card was purchased, or Digium T ec hnical Support (+1. 256.428. 6161). Keep the origina l shi pping container to use for future shipment or proof of damage during shipment.
Note: Only qualified service personnel should install the card. Users
should not attempt to perform thi s function themselves. Shipment Inspection The following items are includ ed in shipment of the TE400 Series:
TE400 Series card (TE405P/407P/ 410P/412P/420/420B)
Release 1.0 Digium, Inc. Page 21
Chapte r 2: C ar d In st a lla tion
Ports
1
2
3
4
Ident
Wheel
PCI 2.2
Connector
Jumpers
Timing
Port
Status
LEDs

Identifying Communication Ports

The TE400 Seri es cards consists of four RJ45 ports and four status LEDs. The ports are used for connecting T1, E1, or J1 cables. Refer to Figure 4 on page 22 or Figure 5 on page 23 to locate the ports and LEDs.
Figure 4: TE405P Card
Release 1.0 Digium, Inc. Page 22
Ports
1
2
3
4
Status
LEDs
Jumpers
Ident
Wheel
PCI Express
Connector
Timing
Port
Chapte r 2: C ar d In st a lla tion
Figure 5: TE420 Card
Release 1.0 Digium, Inc. Page 23
Chapte r 2: C ar d In st a lla tion

T1/E1 Selection

The card includes a row of jumpers to select either T1 or E1 mode for the spans. An exam p le of the jum pe rs fro m the TE 405 car d is sh own i n Figure 6. The T1/E1 mode, in most cases, is set at the distributor before shipment. You may want to check the setting to be certain they are set for your specific use.
Figure 6: T1/E1 Jumpers

Identifying Multip le Cards

If multiple TE400 Series cards are insta lled in the same machine, then the
Ident wheel can be used to control the or der the ca rds are recognize d. The
click wheel switch with the word Ident printed above it can be set to a different num ber for each installed card. This number adjusts the order in which the drive r recognizes the card. For example: set the first card Ident wheel to 0, set the sec ond card Ident wheel to 1, and so on. The Ident wheel is shown in Figure 7.
Release 1.0 Digium, Inc. Page 24
Chapte r 2: C ar d In st a lla tion
Figure 7: Ident Wheel

Connecting Timing Cables

The timing por t allow s up to four TE 4 00 Se rie s card s to share the sa me sync (timing) source from the T1 line provider, or provide a consistent sync source across multipl e cards. This is a useful fea ture for data and fax modes and some voice applications to prevent corruption due to timing slips on the second, third or fourth TE400 Series PC cards.
T o utilize this feature, dai sy-chain the P1 connector between each TE400 Series card using the Digium 4-posi tion timing cable. See Figure 8 on page 26 for an example. Enable this featur e in the drivers using the
timingcable=1 switch when the drivers are loaded:
# modprobe wct4xxp timingcable=1
Release 1.0 Digium, Inc. Page 25
Chapte r 2: C ar d In st a lla tion
Figure 8: Timing Ports
Caution.
Only qualified service personnel should continue with hardware installation and confi guration of the TE400 Series card. Use rs should not attempt to pe rform these functions themselves.
Release 1.0 Digium, Inc. Page 26
Chapte r 2: C ar d In st a lla tion
0
1
2
3
4
Slots

PCI Slot Comp at ib i li ty

Check the type of card you received to be sure it is compatible with your PCI slot. To determine which slot you have, identify it by comparing it to those shown in Figure 9 on page 27.
Slot Number:
0: AGP Pro Slot
1: 64-bit 5.0 volt PCI Slot
2: 64-bit 3.3 volt PCI Slot
3: 32-bit 5.0 volt PCI Slot
4: PCI Express Slot
Figure 9: Motherboard PCI Slots
Release 1.0 Digium, Inc. Page 27
Chapte r 2: C ar d In st a lla tion
The TE405P/407P card is a 32-bit 33MHz card keyed for 5.0 volt operation and works in any PCI 2.2 (or higher) compliant slot which supports 5.0 volts. This means that in the motherboard shown in Fi gure 9, the TE405P/407P card will fit into Slots 1 and 3. The TE405P/407P will not fit into Slot 2.
The TE410P/412P card is a 32-bit 33MHz card keyed for 3.3 volt operation and works in any PCI 2.2 (or higher) compliant slot which supports 3.3 volts. This means that in the motherboard shown in Fi gure 9, the TE410P/412P card will only fit into Sl ot 2. The TE410P/412P will not fit into Slots 1 or 3.
The TE420/TE420B card is a PCI Express card. Slot 4, ill ustrated above, is a 1 lane (X1) PCI Express compliant slot. The TE420/TE420B will work in any PCI Express compliant slot, including lane lengths X4, X8, and X16. This means that in the motherboard shown in Figure 9, the TE420/TE420B will only fit into Slot 4. The TE420 can not be used in Slots 1 through 3.
Release 1.0 Digium, Inc. Page 28
Chapte r 2: C ar d In st a lla tion

Hardware Installat ion

1. Now that you are acquainted with the cards , power down your
computer and unplug it from its power sourc e.
2. Attach a static strap to your wrist a nd open the case .
3. Check the jumper setting to ensure it matches your equipment
configuration. Setting the jumper with the switch on enabl es the ports
for E1. Setting the jumper with the switch off enables the port s for T 1.
4. Remove the bracket place holder and insert the card into the PCI or
PCI Express slot. See Figure 10 for an example of card installation.
Figure 10: Insert th e C ar d
5. Replace the cover to your computer.
6. Plug all T1 or E1 equipment cables into the RJ45 ports as needed.
Note: It is recommended that you use shielded cables.
Release 1.0 Digium, Inc. Page 29
Chapte r 2: C ar d In st a lla tion
Caution.
This unit must be connected to the Teleco mmu nications Network in your country using an approved line cord, e.g.: for Australia use only line cords complying with ACA Technical Standard TS008.
Caution.
This unit must be connected only to the appr opriate Telecommunications Network por t (as approved for use in your specific country).

Softw a r e In s t al la t io n

The card is only supported under Linux. Digium, Inc. recommends Debian, Fedora, and Red Hat, however, all other distributions are supported by Digium Technical Support. Digium hardware requires drivers and librarie s that are integrated with the Linux kernel. You can obtain the source code from ftp.digium.com
. Detailed instructions are
provided in this section . T o install software for your TE400 Series card, you will need:
Full Linux kernel 2.6 (or later) sour ce code.Development librarie s and head ers for libncurses (only necessary for
Asterisk).
Development librarie s and head ers for zlib and openssl.If you are using the 1.2.x series of Aste risk and Zaptel, you will need
Asterisk 1.2.18 or newer, and Zaptel 1.2.18 or newer. If you are using
the 1.4.x series of Asterisk and Zaptel, you will need Asterisk 1.4.4 or
newer and Zaptel 1.4.3 or newer. If you are using Asterisk Business
Edition, you will need version B. 2 or newer.
Release 1.0 Digium, Inc. Page 30
Chapte r 2: C ar d In st a lla tion
1. Check your lspci PCI device listing. Boot the computer into Linux.
After the machine has loaded, log in and execut e the following:
# lspci -n
Confirm your lspci PCI device listing by scanning f or the following
information in the output screen:
0000:01:0e.0 ISDN controller: Unknown device
d161:<card identifier>
In the device listing shown above, <card identifier> will be populated
with one of the identifiers listed in the table below.
Table 1: Card Identifiers
Model Identifier
TE420B TE420 TE412P TE410P TE407P TE405P
0420 0420 0410 0410 0405 0405
A Digium TE400 Series (TE420B/TE420/412P/410P/407P/405P)
ISDN Controller should be identi fied. If a controller is not identified,
then your machine is not PCI 2.2 (or higher) or PCI Express
compatible and the card will not work with your equipment.
Release 1.0 Digium, Inc. Page 31
Chapte r 2: C ar d In st a lla tion
2. Download the latest Zaptel drivers (1.2.17 or later) to your /usr/src
directory. The Zaptel drivers can be downloaded using either ftp or http. They are accessible via ftp from ftp://ftp.digum.com/pub/zaptel. They are acces sibl e v ia http fro m http://ftp.digium.com/pub/zaptel/.
The following example is one way that you could download the
drivers to your /usr/src directory:
# wget http://ftp.digium.com/pub/zaptel/zaptel-1.X.X.tar.gz
where the X.X stands for the version of Zaptel you are downloading.
3. Expand the downloaded tarball an d insta ll the drivers:
#cd /usr/src
#tar -zxvf zaptel-1.X.X.tar.gz
#cd zaptel-1.X.X
#make clean
#./configure (applies to 1.4.X only)
#make menuselect (applies to 1.4.X only if you wish
to customize the install)
#make
#make install
Note: If you don’t already have configuration files installed, you can
type make samples to install the default sample configuration files.
Release 1.0 Digium, Inc. Page 32
Chapte r 2: C ar d In st a lla tion
4. Downloa d the latest released vers io n of As te risk (1 .2. 1 8 or late r).
Asterisk can be downloaded using ftp or http. It is accessible via ftp
from ftp://ftp.digum.com/pub/asterisk. It is also accessible via http
from http://ftp.digium.com/pub/asterisk. The following ex ample is one
way that you could download the drivers to your /usr/src directory:
# wget http://ftp.digium.com/pub/zaptel/
asterisk-1.X.X.tar.gz
where the X.X stands for the ve rsion of Aste risk you are downloa ding.
5. Expand the downloaded tarballs. Substitute the version of Asterisk
you are using with the XX in the command lines below.
# tar -zxvf asterisk-1.2.xx.tar.gz
# cd asterisk-1.2.xx/
# make
# make install
If the build fails, it may be because you are missing one of the build
dependencies, the kernel source, or development tools. Feel free to
contact your res e ller wher e the card was purchas ed, or call Digi um
Technical Support (+1.256.428.6161) for assistance.
Note: Complete instructions for installing Asteri sk are available at
www.asterisk.org
Release 1.0 Digium, Inc. Page 33
.

Chapter 3 Configuration

The TE400 Series cards have a variety of configuration options. This chapter provides confi gurations for PRI, channel bank, E&M wink, and finally, data mode. These sample configur ations are pr ovi ded to assi st y ou in familiarizing yourself with the flexibility of editing the configuration files to meet your specific needs. The list of possibl e configur ations is too expansive to cover in this user manual.

Configuring T1/E1 Lines

1. Begin by opening the zaptel.conf file from the /etc/asterisk/
directory.
2. Configure the SPAN Map.
For each T1/E1 you are using you will need to define a span. The
SPAN map includes defini ng the SPAN number, t iming, li ne build out ,
framing and coding. Configuration details for each of these items is
explained in this section.
span => NUMBER,TIMING,LINE BUILD OUT,FRAMING,CODING
Number:
This is the port the spa n is plugged into. Port 1 being the furthest span
from the PCI bus . Th e por t num ber s are not ed on the PCI bracket.
Release 1.0 Digium, Inc. Page 34
Chapter 3: Configuration
Timing:
Determines whether the card provides timing (0), takes timing (1),
takes backup span timing (2), provides backup span timing (3), and so
on. Only one span can be defined to take timing and it defines timing
for the rest of the card s pan s .
Line Build Out
For most setups the line build out is 0.
0: 0 db (CSU) / 0-133 feet (DSX-1)
1: 133-266 feet (DSX-1)
2: 266-399 feet (DSX-1)
3: 399-533 feet (DSX-1)
4: 533-655 feet (DSX-1)
5: -7.5db (CSU)
6: -15db (CSU)
7: -22.5db (CSU)
Framing
T1 utilizes framing set for D4 (SF) or ESF. E1 utilizes CAS or CCS.
Coding
T1 coding can be AMI or B8ZS. E1 coding can be AMI or HDB3. E1
can also have the extra flag CRC4 at the end for CRC4 checking.
Yellow flag can also be added at the end for transmitting a yellow
alarm when all channels are in use.
Release 1.0 Digium, Inc. Page 35
Chapter 3: Configuration
The following is a typical setup for a telco in the US:
span => 1,1,0,esf,b8zs
In Europe:
span=>1,1,0,ccs,hdb3
First Example: Channel Bank
The Channel Bank in this example has 24 FXS ports. In this configuration, the
zaptel.conf is set for the card to provide timing to the
channel bank and fxoks is set for 24 stations.
zapata.conf to mirror the configur ation with signalling=fxo_ks
Set and define it for channels 1-24.
/etc/zaptel.conf:
span=1,0,0,esf,b8zs
fxoks=1-24
/etc/asterisk/zapata.conf:
group=1
context=channelbank
signalling=fxo_ks
channel=1-24
Release 1.0 Digium, Inc. Page 36
Chapter 3: Configuration
Second Example: E&M Line
In the E&M Line configur ation, the zaptel.conf is set for the card to take timing from the telco on E&M with wink while zapata.conf mirrors the configuration. However, Fea t_D is a type of E&M with wink that accepts DID, but there are many E&M options; E&M_W, E&M, Feat_B, etc.
/etc/zaptel.conf:
span=1,1,o,esf,b8zs
e&m=1-24
/etc/asterisk/zapata.conf:
group=1
context=incoming
signalling=feat_d
channel=1-24
Third Example: PRI
By setting the card to take timing in zaptel.conf, you acquire 23 b channels and voice channels, with channel 24 as the data transport. For Asterisk, define PRI_CPE so it is the client side. Define the switch type you are connecting to as national. There are several opti ons for the swi tch type including 5ESS, 4ESS, and NI1. You will then have 23 voice channels fo r Asteri s k.
Release 1.0 Digium, Inc. Page 37
PRI T1
/etc/zaptel.conf:
span=1,1,0,esf,b8zs
bchan=1-23
dchan=24
/etc/asterisk/zapata.conf
group=1
signalling=pri_cpe
switchtype=national
context=incoming
channel=1-23
PRI E1
/etc/zaptel.conf:
span=1,1,0,ccs,hdb
bchan=1-15,17-31
dchan=16
Chapter 3: Configuration
/etc/asterisk/zapata.conf
group=1
signalling=pri_cpe
switchtype=euroisdn
context=incoming
channel=1-15,17-31
Release 1.0 Digium, Inc. Page 38
Chapter 3: Configuration
Fourth Example: Data Mode
Data mode is a little different than the other options. The zaptel.conf is configured as follows:
/etc/zaptel.conf
span=1,0,0,esf,b8zs
nethdlc=1-24
Instructions for Cisco HDLC:
1.
Compile kernel with HDLC support:
Note: We suggest that you use either a Kernel version of 2.4.20 or
less, or a Kernel of 2.6.8 or greater. The HDLC implementation in the
interval kernels is in a state of too much flux. The following data
modes are described in this section:
WAN Interfaces Support
Generic HDLC Layer
Cisco HDLC support
2. Rebuild and reboot into your kernel.
3. Uncomment the followin g line in zconfig.h of the Zaptel pack age:
#define CONFIG_ZAPATA_NET
If you are using a kernel prior to 2.4.19, also uncomment this line:
#define CONFIG_OLD_HDLC_API
Release 1.0 Digium, Inc. Page 39
Chapter 3: Configuration
Rebuild Zaptel including the creation of the SetHDLC utility:
make sethdlc-new;use "make sethdlc" for
;kernels 2.4.19 and prior
make install
4.
Load and configure your driver :
modprobe wct4xxp
ztcfg
5.
Use sethdlc to bring up the interface:
sethdlc hdlc0 cisco
-or- for old style (mak e sethdlc instead of sethdlc-new) use:
sethdlc hdlc0 mode cisco
6.
Assign the interface an address:
ifconfig hdlc0 192.168.0.1 netmask 255.255.255.0
7.
The interface may be addressed as any other networking interface
(i.e., eth0) in Linux.
Release 1.0 Digium, Inc. Page 40
Chapter 3: Configuration

T esting Y our confi guration.

1. Load Zaptel drivers into the kerne l using the program modprobe. The
appropriate driver for the TE400 Series cards is
wct4xxp. Users in all
countries except Austra lia should use the following modprobe
command:
# modprobe wct4xxp
ztcfg -vv
dmesg screen import
Figure 11: dmesg Screen Capture
Note: Output as shown above may vary depending on the TE400
Series card you use.
Release 1.0 Digium, Inc. Page 41
Chapter 3: Configuration
2. Run zttool from the command line and see if the span turns g reen for
each span you h ave co n nect ed.
zttool
Execute the follo w ing A ste ri sk command to see if the span came up
3.
successfully.
asterisk
asterisk -vvvr
Release 1.0 Digium, Inc. Page 42

Chapter 4 Troubleshooting

This chapter provides frequently asked questions as identified from Digium Technical Support and possible resolutions. Multiple resourc es are available to obtain more infor mation about Asterisk and Digium products. These resources are listed on page 48.
What do the LE D co lor s indicate?
Green - Card is in-sync with the far end.Yellow - Card is synchronizing.Red - Card is not seeing far end, circuit is not up, or cable is bad.
How do I identi fy wh i ch card I have using soft w are?
Check your
lspci PCI device listing. Boot the computer into Linux. After
the machine has loaded, log in and execute the fol lowing:
# lspci -n
Confirm your lspci PCI device listing by scanning f or the following information in the output screen:
0000:01:0e.0 ISDN controller: Unknown device
d161:<card identifier>
In the device listing shown above, <card identifier> will be populated
with one of the identifiers listed in the table below.
Release 1.0 Digium, Inc. Page 43
Chapter 4: Troubleshooting
Table 2: Card Identifiers
Model Identifier
TE420 TE412P TE410P TE407P TE405P
0420 0412 0410 0407 0405
A Digium TE400 Series (TE420/412P/410P/ 407P/405P) ISDN
Controller should be ident ified. If a controller is not identified, then
your machine is not PCI 2. 2 (or highe r) or PCI Expr ess compatibl e and
the card is not working with your equipment.
I can't receive DID calls even though I have it enabled in extensions.conf.
Your telco might be sending calls with a method you are not expecting.
1. Check the method being used by attempting the following in your line
context:
_x.,1,noop(My DID Matches as ${EXTEN}
2.
Then type reload in the Asterisk console and call in. You should see
the DID come in on your T1/E1 line.
Page 44 Digium, Inc. Release 1.0
Chapter 4: Troubleshooting
My D Channel seems to go up and down.
Check to be sure you have set your timing parameters correctly. Also check the common causes of problems for a T1. See the Common Fixes
for all cards , page 47.
I have trouble dialing out. It seems that one type of dialing works (local, long distance, international) but another does not.
Check your
pridialplan variable and be sure that you a re di aling us ing the
method your telco is expecting .
I am having trouble receiving DID information over E&M.
Try the other types of E&M (featd, featb, etc.) to match the method your telco is using to stream infor mation.
I am having issues with my PRI. How can I see the messages coming across my D chan nel?
Enter the following command:
PRI debug span X
where x is the port from which you are connected. This command will show you the PRI messages coming across your D channel for that message.
Release 1.0 Digium, Inc. Page 45
Chapter 4: Troubleshooting
I am still having problems and the telco tells me it is my equipment.
The first thing to do in this situat ion is to test your equipment.
1. Plug in a loopback cable. (A loopback cable is a cable that has pin 1
going to pin 4 and pin 2 going to pin 5.) Plug the cable into the span
and wait for its LED to turn green.
2. Stop Asterisk and edit zaptel.conf by removing the lines define d for
your card and replacing them with the following:
span=>1,0,0,esf,b8zs
clear=1-24
Or if you have an E1 span:
span=> 1,0,0,ccs,hdb3
clear=1-31
Navigate to your zaptel source directory and type:
3.
make tests
Followed by:
./patlooptest /dev/zap/1 60
The first argument in the patlooptest command is the device for the
channel number you want to test. You should always test the first
channel of a span. The second argumen t i s the duration in seconds to
run the test.
Page 46 Digium, Inc. Release 1.0
Chapter 4: Troubleshooting
This runs a pattern looptest for 60 seconds. If you receive any failures,
it is possible you have a bad card and will need to call Digium
Technical Support (+1.256.428.6161)
Common F ixe s for all cards
1. Check to see if X windows is running by entering the followin g:
ps aux|grep X
If X windows is running, stop the application since it may cause a
conflict with Asterisk.
2. Check to see if your hard drives are running with DMA levels set.
Perform an hdparm on your hard drive interface.
If you are still having proble ms conta ct your reseller where the card
was purchased, or Digium Technical Support (+1.256.428.6161).
How can I enable more features?
To view all of the options available to add to your dial plan, type the following command from within Aster isk:
show applications
Digium also offers services to help configure and add features you might need. Contact Digium Technical Support (+1.256.428.6161) for more information.
Release 1.0 Digium, Inc. Page 47
Chapter 4: Troubleshooting
Where can I find answers to additional questions?
There are several places to inquire for more information about Asterisk Digium products:
1. Digium Technical Support (+1.256.428.6161), or Toll Free in the U.S.
(1.877.546.8963), is available 7am-7pm Central Time (GMT -6),
Monday - Friday.
2. Asterisk users mailing list (asterisk.org/lists.digium.com).
3. IRC channel #asterisk on (irc.freenode.net).
Maintena n ce Su ppo rt Program
Digium is dedicated to support ing your Asterisk system by offering full technical support through our Maintenance Support Program. The Maintenance Support Progra m covers all Digium hardware and the complete Asterisk softwa re suite. Through this program, you can be at ease knowing that your business will always have access to the Asterisk experts. To obtain a quote for maintenan ce please contact Asterisk Express sales at +1.256. 428.6060 or express@digium.com.
Page 48 Digium, Inc. Release 1.0
Appendix A
Pin 8
Pin 1
Pin Assignments
All four ports on the TE400 Series c ard bracket are 8-pin RJ45 ports. The pin assignments are identif ied in Ta ble A-1.
Table A-1: RJ45 Telco Port C onnector
Pin Description
1Rx 2Rx 3Not used 4Tx 5Tx 6Not used 7Not used 8Not used
Release 1.0 Digium, Inc. Page 49

Appendix B Specifications

This appendix provides specifications, required environmental conditions, and maximum power consumption for the Asterisk Appliance card.
Physical (All Cards).
Size: 5” × 3.75” × 0.63” (12.7 x 9.53 x 1.6 cm)
PCB size, does not include the PCI bracket
Weight: 3.5 oz (100gm) - Without Echo Cancellation Module
Interfaces.
Local Loop Access: E1, T1, J1, PRI; RJ45 (TE405/410) - PCI Bus: 3.3V or 5V bus slot, half-length slot minimum size, 33MHz minimum bus speed, compliant with PCI
2.2 or greater.
(TE420) - PCI-E X1, compliant with PCI-E X1 1.0 or greater.
Environment.
Temperature: 0 to 50° C (32 to 122° F) operation
-20 to 65° C (4 to 149° F) storage
Humidity: 10 to 90% non-condensing
Release 1.0 Digium, Inc. Page 50
Appendix B: Specifications
Hardware an d Softw a re Requirements.
800-Mhz Pentium III or better 64MB RAM Available PCI (TE405/41) or PCI-E (TE420) Slot
Table B-2: Maximum Power Consumption
Model Power
TE420B
3.3V 5 W atts TE420
3.3V 2.5 Watts TE412
3.3V 5V
TE410
3.3V 5V
3.0 Watts
0.5 Watts
2.0 Watts 0 W atts
TE407
3.3V 5V
3.0 Watts
0.5 Watts
TE405
3.3V 5V
Release 1.0 Digium, Inc. Page 51
2.0 Watts 0 W atts

Appendix C Gloss ary and Acronyms

ANSI American National Standards Institute
An organization which proposes and establishes standards for international communications.
asynchronous
Not synchronized; not timed to an outside clock source. Transmission is controlled by start bits a t the beginning and stop bits at the end of each character. Asynchronous communications are often found in internet access and remote office applications.
attenuation
The dissipation of a transmitted signal’s power as it travels over a wire.
bandwidth
The capacity to carry traffic. Higher bandwidth indicates the ability to transfer more data in a given time period.
bit
The smallest element of information in a digital system. A bit can be either a zero or a one.
bps bits per second
A measurement of transmission spe ed across a data connection.
Release 1.0 Digium, Inc. Page 52
Appendix C Glossary and Acronyms
broadband
Broadband transmission sha res the bandwidth of a particular medium (copper or fiber optic) to integrate multiple signals. The channels take up different f requencies on the cable, integrating voic e, data, and video over one line.
channel
A generic term for an individual dat a stre am. Ser vice providers can use multiplexing techniques to transmit multiple channels over a common medium.
Cat5
Category of Performance for wiring and cabling. Cat 5 cabling support applications up to 100 MHz.
Cat5E
Category of Performance for wiring and cabling. Category 5 Enhanced wiring supports signal r ates up to 100 MHz but adheres to stricter quality specifications.
CLEC competitive local exchange carrier
A term for telephone companies established after the T elecommunications Act of 1996 deregulated the L ECs. CLECs compete with ILECs to offer local service. See als o LEC and ILEC.
Release 1.0 Digium, Inc. Page 53
Appendix C Glossary and Acronyms
CO central office
The CO houses local switching equipment. All local access lines in a particular geographic area terminate at this facility (which is usually owned and operated by an ILEC).
CPE customer premises equipment
T erminal equipment which is connected to the te lecommunications network and which resides within the home or of fice of the customer . This includes telephones, modems, terminals, routers, and television set-top boxes.
DS0 Digital Signal, Level 0
A voice grade channel of 64 Kbps. The worldwide standar d speed for digitizing voice conversation using PCM (Pulse Code Modulation).
DS1 Digital Signal, Level 1
1.544 Mbps in North America (T1) and Japan (J1) -up to 24 voice channels (DS0s), 2.048 Mbps in Europe (E1) - up to 32 voice channels (DS0s). DS1/T1/E1 lines are part of the PSTN.
DS3 Digital Signal, Level 3
T3 in North America and Japan, E3 in Europe. Up to 672 voice channels (DS0s). DS3/T3/E3 lines are not part of the PSTN
DTMF Dual Tone Multi-Frequency
Push-button or touch tone dial ing.
Release 1.0 Digium, Inc. Page 54
Appendix C Glossary and Acronyms
E1
The European equivalent of North Ameri can T1, transmits data at 2.048 Mbps, up to 32 voice channels (DS0s).
E3
The European equival ent of North American T3, transmits data at 34.368 Mbps, up to 512 voice channels (DS0s). Equivale nt to 16 E1 lines.
EMI E lectromagnetic Interference
Unwanted electrical noise present on a power line
full duplex
Data transmission in two directions simultaneously.
FXO Foreign Exchange Office
Receives the ringing volta ge from an FXS device.
FXS Foreign Exchange Station
Initiates and sends ringing voltage.
G.711
The International Telecommunications Union recommendation for an algorithm designed to tr ansmit and receive mulaw PCM voice and A-law at digital bi t rate 64 Kbps. This al gorithm is u sed for digita l t elephone sets on digital PBX.
Release 1.0 Digium, Inc. Page 55
Appendix C Glossary and Acronyms
G.729
An International Telecommunications Union standard for voice algorithm.
H.323
An International Telecommunications Union standard for multimedia communications over packet -based networks.
IAX Inter- A steri sk eXchange
A VoIP protocol used by Asterisk. It is used to enable VoIP connections between As teri s k server s , and betw ee n serv e rs and clie nts that als o us e the IAX protocol.
iLBC internet Low Bitrate Codec
A free speech codec used for voice over IP. It is designed for narrow band speech with a payload bitrate of 13.33 kbps (frame length = 30ms) and
15.2 kbps (frame length = 20 ms).
ILEC incumbent local exchange c arrier
The LECs that were the or iginal carr iers in the market pr ior to th e entry of competition and theref ore have the dominant position in the market.
interface
A point of contact between two systems, networks, or devices.
Release 1.0 Digium, Inc. Page 56
Appendix C Glossary and Acronyms
ISO International Standards Organization LED light-emitting diode
Linux
A robust, feature-packed open source operating system based on Unix that remains freely available on the internet. It boasts dependability and offers a wide range of compatibility with hardware and software. Asterisk is supported exclusively on Linux.
loopback
A state in which the transmit signal is reversed back as the receive signal, typically by a far end network element.
MGCP Media Gateway Control Protocol
multiplexing
Transmitting multiple signals over a single line or channel. FDM (frequency divisi on multiplexing) and TDM (time division multiplexi ng) are the two most common methods. FDM separates signals by dividing the data onto different carrier frequencies, and TDM separates signals by interleaving bit s one after the other .
MUX multiplexer
A device which transmits multipl e signals over a single communications line or channel. See multiplexing.
Release 1.0 Digium, Inc. Page 57
Appendix C Glossary and Acronyms
PBX private branch exchange
A smaller version of a phone company’s large centra l switching office. Example: Asterisk.
PCI periph eral compo nent interconnect
A standard bus used in most computers to connect peripheral devices.
POP point of presence
The physical connection point between a network and a telephone network. A POP is usually a network node serving as the equivalent of a CO to a network service provider or an interexchange carrier.
POTS plain old telephone service
Standard phone service over the public switched telephone network (PSTN). This service provides analog bandwidth of less than 4 kHz.
PPP point-to-point protocol
Type of communications link that connects a single device to another single device, such as a remote terminal to a host computer.
PSTN public switched telephone network
A communications network which uses telephones to establish connections between two poin ts. Also referred to as the dial network.
QoS quality of service
A measure of telephone service, as specified by the Public Service Commission.
Release 1.0 Digium, Inc. Page 58
Appendix C Glossary and Acronyms
RJ11
A six-pin ja ck typically used for connecting telephones, modems, and fa x machines in residentia l and business settings to PBX or the local telephone CO.
SIP Session Initiation Protocol
An IETF standard for setting up sessions be tween one or more clients. It is currently the leading signaling protocol for Voice over IP, gradually replacing H.323.
T1
A dedicated digital carrier facility which transmits up to 24 voice channels (DS0s) and transmit s data at 1.544 Mbps. Commonly used to carry traff ic to and from private business networks and ISPs.
T3
A dedicated digital carrie r facility which consists of 28 T1 lines and transmits data at 44.736 Mbps. Equivalent to 672 voice channels (DS0s).
TDM time division multiplexer
A device that supports simul taneous transmissi on of multiple data streams into a single high-speed dat a stre am. TDM separa tes signals by interleaving bit s one after the other .
telco
A generic name which refers to the telephone companies throughout the world, including RBOCs, LECs, and PTTs.
Release 1.0 Digium, Inc. Page 59
Appendix C Glossary and Acronyms
tip and ring
The standard terminati on on the two conduct ors of a telephone circuit; named after the physical appear a nce of the contact areas on the jack plug.
twisted pair
T wo copper wires commonly used for telephony and data communications. The wires are wrapped loosely around each other to minimize radio frequency interference or interference from other pairs in the same bundle.
V volts VoIP Voice over IP
T echnology used for transmitti ng voice traffic over a data network using the Internet Protoco l.
Zaptel (Zap)
Zapata Telephony Project dedicated to implementing a reasonable and affordable Computer Tele phony platform into the world marketplace.
Release 1.0 Digium, Inc. Page 60
Loading...