Digitron EX-9486-W Operation Manual

EX-9486-W
Serial to WI-FI Converter
Operation Manual
First Edition, Oct 2007
1
Table of Contents
1. Introduction ………………………………………………… 3 Overview ………………………………………………… 4 Package Check List ………………………………………… 5 Product Features …………………………………………… 6 Hardware Specifications …………………………………… 8
2. Converter Description ……………………………………… 11 Product Panel Views ……………………………………… 11 Top Side …………………………………………………… 11 Right Side ………………………………………………… 12 Left Side …………………………………………………… 13 Rear Side ………………………………………………… 13 LED Indicators …………………………………………… 14 Wiring Architecture ……………………………………… 15 RS-232 …………………………………………………… 15 RS-422/RS-485 …………………………………………… 15
3. EX-9486-W Configuration ……………… 16 Software Setup and Initial IP Configuration …………… 16 EXTool Software Setup ……………………………… 17
EXTool Setup …………………………………… 17 Serial to Wi-Fi Configuration ……………………………… 19 Broadcast ……………………………………………………… 19 Device List …………………………………………………… 20
General ………………………………………… 20
Security ………………………………………… 21
Networking ……………………………………… 22
Wireless ………………………………… 22
Notification ……………………………………………… 23
2
Management …………………………………………… 23
Upgrade Firmware ……………………………… 24
Save/Load ………………………………………… 24 Port ………………………………………… 26
Serial Settings ………………………………………… 26
Service Mode ………………………………………… 27
Notification ……………………………………… 28
VCOM List ……………………………………… 30 Setup Wizard ……………………………… 31
Virtual Com Wizard ……………………………………… 31
Serial Tunnel Wizard ……………………………………… 33
Group IP Wizard ……………………………………… 34
Group Setup Wizard ……………………………………… 35
Group Firmware Wizard ……………………………… 37
IP Collection ……………………………………… 38 System Log ……………………………… 39
4. Web Console Configuration ……………… 40
Appendix A - FAQ ………………………………………… 38 Appendix B - Pin Outs and Cable Wiring ………… 39 DC Power Outlet ………………………………………… 39 RJ-45 Pin Assignment …………………………………… 39 RS-232 Pin Assignment ………………………………… 39 RS-232 Wiring Diagram ………………………………… 40 RS-422 Pin Assignment ………………………………… 40 RS-422 Wiring Diagram ………………………………… 40 RS-485 Wiring Diagram ………………………………… 40
3
11
Introduction
Serial-Server is providing new ways of connecting legacy serial converter devices to a Local Area Network (LAN) or Wide Area Network (WAN). EX-9486-W is designed to operate serial ports through wireless(Wi-Fi 802.11b & g) or entity line(RJ-45 cable) over 100Mbit/s Ethernet networks. The data is transmitted via TCP/IP protocol. Therefore control is available via Ethernet, Intranet and Internet. EX-9486-W is packaged in a case well suited for industrial environments. All serial ports operate in common RS-232 mode , industrial RS-422 and RS-485 modes configuration.
EX-9486-W is a low-cost, high performance design. By careful selecting high quality with competitive prices components in the world, products made network connectivity possible with affordable cost for virtually all kinds of devices.
The EX-9486-W can connect the Remote I/O Control module of EX9000 Series for EX9000 Series to Wireless by RS-232/422/485. This operation manual will guide you step by step for the various functions of the EX-9486-W.
The following topics are covered in this chapter:
OverviewPackage Checklist Block Diagram Product Features Product Specifications
4
Overview
EX-9486-W(ARM-9/200MHz SRAM/16MB FlashROM/8MB) is provide a perfect solution to make your industrial serial devices Internet ready instantly via wireless LAN. ARM-9 Series of EX-9486-W makes them the ideal choice for connecting your RS-232 or RS-422/485 serial devices—such as PLCs/ meters/EX-9000 Series—to an IP-based Wi-Fi Ethernet LAN, making it possible for your software to access serial devices anywhere and anytime over a wireless local LAN or the Internet.
ARM-9 Series of EX-9486-W ensures the compatibility of network software that uses a standard network API (Winsock or BSD Sockets) by providing TCP Server Mode, TCP Client Mode, and UDP Mode. And thanks to ARM-9 Series’ Real COM/TTY drivers, software that works with COM/TTY ports can be set up to work over a TCP/IP network in no time. This excellent feature preserves your software investment and lets you enjoy the benefits of networking your serial devices instantly.
ARM-9 Series of EX-9486-W support manual configuration via the handy web browser console and many protocols including TCP, IP, UDP, HTTP, DHCP, ICMP, and ARP. They are the best solution to network your serial devices.
5
Package Check List
EX-9486-W product is shipped with the following items:
□□ 1 unit of EX-9486-W
□□ 1 unit of Power Adaptor (12V DC, 1.2A)
□□ 2 unit of dipole antenna(2.0dBi / 5.0dBi)
□□ Documentation & Software CD
□□ Quick Installation Guide
NOTE: Notify your sales representative if any of the above items is missing or damaged.
6
Product Features
Data Conversion between RS-232/422/485 and Ethernet
Convert serial device (RS-232, RS-422, RS-485) data/signal into the TCP/IP package data/signal and send them out with the Ethernet DataStream; or convert the TCP/IP package data/signal into serial device data/signal.
Wi-Fi Wireless Ethernet
It based on the latest industry standard Wi-Fi Certified IEEE 802.11g
specification; it offers maximum channel speeds of up to 54 Mbps. The Wi-Fi function maintains interoperability within the 2.4 GHz frequency band,
offering full compatibility with 802.11b networks. This integrated wireless
solution of EX-9486-W is widely deployed in business environments and is the standard for wireless access in public places. It also supports key security features like Wi-Fi Protected Access (WPA), WEP and 802.1x.
Dynamic IP Configuration
Support DHCP client mode, simplifying network address configuration and management.
Dual LAN Speed
Support 10/100 Mbps Ethernet, auto-detected.
Server / Client Dual Modes
Series can be configured as network server or network client. In the client mode, it can be installed in network which is protected by NAT router or firewall, without the need of a real IP address.
7
Web-based Setup
Parameters setup is based on HTTP protocol by using standard browsers (IE and Netscape). No special software would be required.
Built-in Security Control
Protected by both setup password and access password to prevent intruders.
Remote updated
Firmware can be reprogrammed directly via Ethernet network to keep up with latest network standards.
8
Hardware Specifications
WLAN
1. Port Type : RJ-45 ConnectorStandard Compliance: IEEE 802.11b/g
2. Spread Spectrum Technology: DSSS, OFDM
3. Tx Power 11b: Maximum 20 dBm
4. Tx Power 11g: Maximum 18 dBm
5. Rx Sensitivity: -70 dBm @ 54 Mbps, -85 dBm @ 11Mbps
6. Transmission Rate: 54 Mbps (max.) with auto fallback (54,48, 36, 24, 18, 12, 11, 9, 6, 5.5, 2, 1 Mbps)
7. Transmission distance: Up to 300 meters(@12 Mbps, in open areas)
8. Security: WEP 64-bit/128-bit data encryption, AES, WPA2
9. Antenna Connector: Reverse SMA
10. Network Mode: Infrastructure, Ad-Hoc
LAN for configuration / Ethernet hub
1. Ethernet: 10/100 Mbps, RJ45
2. Protection: Built-in 1.5 KV magnetic isolation
Serial Communication Parameters
1. No. of ports : 1 RS-232/422/485 port, male DB9, S/W selectable
2. RS-232 Signals : TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
3. RS-422 Signal : Tx+ , Tx- , Rx+ , Rx –
4. RS-485 Signal : Data+ , Data-
5. Serial Line Protection : 15 KV ESD for all signals
Beeper for event warning or unit positioning ( Optional)
9
Serial Communication Parameters
1. Parity: None, Even, Odd, Space, Mark
2. Data bits: 5, 6, 7, 8
3. Stop bits: 1, 1.5, 2
4. Flow control: RTS/CTS, XON/XOFF
5. Speed: 110 bps to 460.8+ Kbps
Power Requirements & Consumption
1. Power Input : 9 -12 VDC/500mA -1.2A
2. Power Line protection :
1 KV Burst (EFT), EN61000-4-4  0.5 KV Surge, EN61000-4-5
Environmental
1. Operating Temperature : -10 to 70°C (32 to 131°F), 5 to 95% RH
2. Storage Temperature : -20 to 85°C (-4 to 185°F), 5 to 95%RH
3. Regulatory Approvals
 RoHS  EMC: FCC Class A, CE Class A  Safety: UL, CUL, TÜV  Class I, DIV II
Software Features
1. Protocols : ICMP, IP, TCP, UDP, DHCP, BootP, ARP / RARP, Telnet,
RTelnet, DNS, SNMP MIB II, HTTP, SMTP, SNTP
2. Serial mode : Virtual Com / TCP Server / TCP Client / UDP / Serial
Tunnel with advanced settings of
TCP Alive Check Timeout Inactivity Timeout Delimiter for Data Packing Force TX Timeout for Data Packing
10
4 Hosts simultaneous connection : Virtual Com / TCP server / TCP Client
(only raw data)
1. Modbus support: (optional software)
2. PPPOE, DDNS : (optional software)
3. Security: HTTPS, SSH v2
4. Event notification by email / SNMP trap SNMP Trap
Cold/Warm Start DSR, DCD Changed IP Changed Authentication Fail
SNMP Response
System MIB, Interface MIB, ICMP, IP, TCP MIB UDP MIB RS-232 MIB
5. Utilities : Windows NT/2000/XP/2003/VISTA
Device discovery Auto IP report
Device setting (run-time change, no rebooting)
Access control list  Group setting  Device monitoring  Serial port monitoring  Log info  Group Firmware update batch
Virtual COM/TTY Drivers (WDM mode, configuration in windows device manager) : Windows
NT/2000/XP/2003, VISTA
11
22
Converter Description
Product Panel Views
Top Side
LAN RJ-45
DC-In
Power Outlet
Serial I/O Port
RS-232
Serial I/O Port
RS-485/RS-422
Reset Button
Terminator
LED Indicators
USB Port
Antenna
12
Right Side
DC-In Power Outlet
The EX-9486-W is powered by a single 912V DC(Inner positive/outer
negative) power supply and 500~1200mA of current. A suitable power supply adapter is part of the packaging. Connect the power line to the power
outlet at the right side of EX-9486-W and put the adapter into the socket. If
the power is properly supplied, the “SYS” green color LED will be on
USB Port
The EX-9486-W of USB port is.
Antenna Connector
The connector for antenna is a standard SMA jack. Simply connect it to a
2.0dBi or 5.0dBi dipole antenna (Standard Rubber Duck) and it is 50 Ohms impedance and can support 2.4GHz frequency.
Ethernet Port
The connector for network is the usual RJ45. Simply connect it to your
network switch or Hub. When the connection is made, the LAN LED
indicator will light. When data traffic occurs on the network, red (Rx/Tx)
indicator will blink during data transferring and receiving.
Ethernet Port
DC-In
Power Outlet
USB Port Antenna
13
Left Side
Serial I/O Port of RS-232/RS-422/RS-485
Connect the serial data cable between the Wi-Fi converter and the serial device. Follow the parameter setup procedures to configure the converter
(see the following chapters ).
Rear Side
Reset Button
If by any chance, you forget the setup password, or have incorrect settings making EX-9486-W TCP/IP converter inoperable. First, turn off the power. Second, use any point tip to push this button and hold it to turn on the power at the same time for 5 second. All the parameters will be reset to the factory default.
RS-485/RS-422 RS-232
Reset Button
Terminator
14
Terminator
The purpose is for compensating signal attenuation in long distance connection at RS-485/RS-422 I/O. If the switch 1 & 2 are set in “ON” position, the signal compensation will be activated. To disable the function, just push switch 1 & 2 to opposite position.
LED Indicators?
SYS (Red)
Power indicator (When the power is on, the LED will blink once per second.)
LAN (Green)
Network signal indicator (When the LAN signal is detected, the LED will be on.)
TX (Red)
Data sent indicator (When data are sent out to the network, the LED will be on.)
RX (Green)
Data received indicator (When data are received from the network, the LED will be on.)
15
Wiring Architecture
RS-232 Wiring Architecture
RS-422/RS-485 Wiring Architecture
When you finish the steps mentioned above and the LED indicators are as shown, the converter is installed correctly. You can use the Software Setup CD to setup the IP Address.
To proceed the advanced parameter setup, please use a web browser (IE or Netscape) to continue the detailed settings.
16
33
EX-9486-W Configuration
Software Setup and Initial IP Configuration
When setting up your converter for the first time, the first thing you should do is
configure the IP address. This chapter introduces the method how to install the
program and how to configure the EX-9486-W device’s IP address.
For quick and easy start , We suggest you to reference “Quick Installation Guide” manual.
The following topics are covered in this chapter:
EXTool Software Setup EX-9486-W Configuration Converter Configuration through Web
17
EXTool Software Setup
On PC we provide a Device Management Utility named EXTool which is an executable program in Windows 32 bit environments. EXTool Setup is used to detect and setup the installed converter. It uses UDP broadcast packets to query and configure converters on the network.
EXTool Setup
Insert the CD and select “EXTool_ODM_Setup”,folder and double click “EXTool_ODM_Setup.exe”, runing to install Windows utility.
When the “installing EXTool” screen is pop-up then double click the “Start” icon for installing.
18
1.1 After finishing installation, the “installation was completed successfully” screen will be pop-up and jus double click the “OK” icon.
1.2 Coming the screen is for choosing to run “Launch EXTool Now” or “Launch EXTool Later”
1.3 If you choice the item of “Launch EXTool Now” then the EXTool of Device Configuration manual screen will be pop-up.
19
EX-9486-W Configuration
Broadcast
After finishing EXTool installation and lunch the EXTool, you can double click the “Broadcast” button at left side upper corner. It will detect the existence of the installed converters on the network.
Select the converters you wish to add and double click “Add” button.
The table will depict the converters’ status such as IP address, MAC Address, Device Name and status.
Device List
In the Device List icon, you will find the added converter in the list and double click on the device will continue to configure other rest of the converter settings.
20
General
After listing of device IP in “Device List” item, You can click the IP as show on table then the General section lists information as “Model”, “IP Address”, and “MAC Address”, “Firmware Version” “Device Name/Location“ and device working status … etc. You can configure some parameters and modify device name and location
The item of “Using SNTP Time Server”
21
Security
EX-9486-W’s Security includes access IP & Mask list table and administration security.
The Access IP Table specifies the IP address and subnet that can access to the device. The access is based on IP and Mask combination. If the access is open to all hosts, do NOT enable this function.
For administration security, You can assign a password for administrator’s management and also to prevent others who are unauthorized to the configurations on the device. If you assign a password, you will need to manage it(Depend on your policy). When you access Windows, Web, or Telnet consoles and it also is validated to “Setup Wizard configuration” function.
After modifying configuration, be sure to validate the changes by using “Apply Only” or “Apply and Save”.
22
Networking
EX-9486-W can support both type of IP such as Static IP or DHCP/BootP IP configuration. After modifying configuration and click the icon of “Apply Only” or “Apply and Save” for finishing IP configuration.
Wireless
You can use the wireless item for configuring EX-9486-W’s Wi-Fi parameters. “SSID Scan” is for searching the available wireless access point and select your AP device. “Wireless Encryption” is for setup parameters as encryption type and key, be sure to validate the changes by using “Apply Only” or “Apply and Save”.
23
Notification
EX-9486-W can support 3 ways of event notification as “SNMP Trap”, “Email Notification” and Syslog Notification.
Management
In addition to EXTool, EX-9486-W can also be managed by Web and Telnet consoles as well as supports SNMP trap.
The device is enabled Web and Telnet consoles functions by default. To enable or disable the management consoles, you can use the “Configuration” and “Management” of EXTool for configuring.
To enable SNMP trap support, you have to check the SNMP Management Enable device and specify SNMP settings including Community, Location, Contact, and Trap Server IP.
24
Upgrade Firmware
You can contact with your vendor for upgrading the latest version firmware of device.
To update firmware of the device, save the firmware file in your host PC from vendor. Go to “Configuration”, and “Update Firmware”. Specify the file location by Browsing and continue operation by Update. The device will reboot after firmware updating and be located again in EXTool’s “Device List” item.
Note:
All parameters will restore to default after the firmware update, except for the device IP address.
Save/Load
After finishing setup, be sure to click “Apply and Save” button.
25
“Apply and Save” is for applying all parameters save and flash but the changes are valid after rebooting the device.
“Load default” is all parameters changes to factory’s default except network setting.
“Reboot Device” is for rebooting device and needs to broadcast again to search the device.
“Import” is for retrieving saved configuration file to apply in current device.
“Export” is saving the current parameters onto a file and export to a
current host for saving.
26
Port
Port Configurations is for configuring as serial parameters, serial communication modes, data packing options, and event notifications.
Serial Settings
Port Alias : Remark the port to the connected device. Baud rate : from 110bps to 460.8kbps Parity : No, Even, Odd, Mark, Space Data Bits : 5, 6, 7, 8 Stop Bits: 1, 2 (1.5) Flow Control : No, XON/XOFF, RTS/CTS, DTR/DSR Interface : RS232 Performance : “Throughput”, guarantees highest transmission
speed.
“Latency”, guarantees shortest response time.
Delimiter Settings
For advanced data packing options, you can specify delimiters for Serial to Ethernet and / or Ethernet to Serial communications.
27
You can define 4 delimiters (00~FF, HEX) for each way and until the delimiters are received, the data will not transmit success.
“Flush Ethernet to Serial Data Buffer After” is for counting the flush times out of data transmitted between Ethernet and Serial.
“Force TX interval time” is for specifying the timeout when no
data
has been transmitted and the timeout is reached or TX buffer is full (4K Bytes), the queued data will be sent. If you want to disable and the parameter is setting “0”. (factory default)
Service Mode
UDP Mode
When device is configured as TCP Server, it gives the connected serial device a unique IP : Port address on a TCP/IP network that it can be accessed by other host on the network. Device as TCP Server waits passively to be contacted by the host computer, allowing the host computer to establish a connection with and get data from the serial device. This operation mode supports up to 5 simultaneous connections, so that multiple hosts can collect data from the same serial device at the same time.
28
Virtual COM Mode
“Service Mode” enables the serial port in EX-9486-W to act and be controlled as PC’s COM port for Windows. One PC can have as many as COM ports on the network without the limitation of PC’s physical slots. The Virtual COM ports on the network can also be shared by multiple hosts.
TCP Client Mode
When EX-9486-W is configured as TCP Client, it allows the connected serial device the ability to initiate actively the TCP connection to remote host software when it needed. When the connection is built, the data is transmitted bi-directionally and till the data transmission is finished, the TCP connection will be closed by TCP Client. The connect-on-demand TCP Client operation helps the host computer to manage high number of remote devices that exceeds the maximum simultaneous TCP connections allowed. EX-9486-W supports up to 5 simultaneous TCP Client connections for redundant system considerations
Notification
Port status can be notified to administrator by email, SNMP trap, or System Log.
There are several events of notification include:
DCD changed: When DCD (Data Carrier Detect) signal
changes, indicating the modem connection status has changed, the event will be triggered.
RI changed: When RI(Ring Indicator) signal changes, indicating
the incoming of a call, the event will be triggered.
29
DSR changed: When DSR (Data Set Ready) signal changes,
indicating that the data communication equipment is powered off, the event will be triggered.
CTS changed: When CTS (Clear To Send) signal changes,
indicating that the transmission between computer and DCE can proceed.
Port connected: In TCP Server Mode, when the device accepts
an incoming TCP connection, this event will be trigger. In TCP Client Mode, when the device has connected to the remote host, this event will be trigger. In Virtual COM Mode, when Virtual COM is ready to use, this event will be trigger.
Port disconnected: In TCP Server/Client Mode, when the
device lost the TCP link, this event will be trigger. In Virtual COM Mode, When Virtual COM is not available, this event will be trigger.
To enable activate the notification, specify the event type and the notification methods. The details of SNMP trap Server, Email SMTP server, or Log server IP should be configured first properly in device “Configuration” “Management”.
30
VCOM List
You can monitor the COM port status from the “VCOM” function. The monitored items can also be defined by the “Select Monitor Items” at right side of upper corner. The COM ports must be configured first before monitoring the status
31
Setup Wizard
EXTool offers 5 Setup Wizards to help you manage Serial Wi-Fi Converter devices as a group and streamline the management tasks.
Virtual COM Wizard
EXTool offers one of the easiest way to add serial COM ports over the network by the Virtual COM Wizard. Serial Wi-Fi Converter COM port driver is installed when you install EXTool . Select the Virtual COM Wizard from Setup Wizard. There are only 3 steps to follow up.
Select the available ports of Serial Wi-Fi Converters on the network.
32
Continue by configuring the serial settings of the serial ports. In Performance mode, there are “Throughput” mode and “Latency” mode. In Throughput mode, the throughput is high. In Latency mode, the response time is low.
Specify the Virtual COM port range and continue the operation by checking the COM port table
33
Serial Tunnel Wizard
The Serial Tunnel Wizard gives you the option to transparently pair two devices over the network.
Select the devices that should be paired and move the devices into IP1 and IP2.
After configuring the serial setting of the ports, the serial tunnel will be built by assigning one port as the TCP Server mode and the other as the TCP Client mode.
34
Group IP Wizard
When you have more than one device to configure, it is handful to use Group IP wizard to configure all IP addresses of the devices remotely.
Select Group IP Wizard after opening EXTool, or use Broadcast and find more than one Converters on the network and double click the button of “Click here” at right side lower corner.
Search the devices in local network (i.e. same subnet), or search by an IP range. Select the devices
Select the devices for group IP configuration and define the IP addresses range or by DHCP.
35
Click next to confirm the setup and the IP configuration is finished, you will see the IP addresses for the devices
Group Setup Wizard
Group Setup Wizard can be help you to copy the configuration of one device to other converters. You can select the items to be copied or not. Go to “Setup Wizard”, “Group Setup Wizard”, and choose “Next” to continue.
Select device model as “Serial Server DS-11-W”.
36
Select the source device for the configuration and destination devices.
Click next to confirm and finish the wizard.
37
Group Firmware Wizard
To update firmware for a group of devices can be as easy as 4 steps of Group Firmware Wizard
Select the device model as EX-9486-W DS-11-W, and select available converters on the network for the upgrade
Specify the firmware image and select next. Confirm the firmware upgrade and continue operation. EXTool will upgrade firmware of the converter and reboot again to finish
38
IP Collection
For the dynamic DHCP IP settings, it is often a task to find the changing IP addresses
EXTool supports auto IP report function to report the current IP address of the EX-9486-W units to administrator. To enable the function, check “Auto IP Report” in “Configuration”, “General”. Specify the host that the device should report IP to, or define current host as the report host.
Be sure to define the Report Interval time. Zero is disable
Go to the IP Collection function of the main menu and find the converters auto IP report list
39
System Log
You can use a calendar at the button of “System Log” screen for searching the history data of log massages.
40
44
Web Console Configuration
After completing the wiring and parameter setting, we should verify if the setting
is correct or not. This chapter will introduce how to use a single computer to
test if the converter behaves well.
The operating system can be Windows 95, 98, ME, XP, 2000. The “Hyper
Terminal” utility should be installed on your PC (see Figure 4.1). It can be
found in your Windows installation CD.
The wiring architecture is similar to “RS-232 Wiring” in chapter 2, and the
“Serial Device” is replaced by the PC’s COM 1. The same PC also plays the
roll of the Remote Host.
The following topics are covered in this chapter:
Hyper Terminal for TCP/IP WinSock
Hyper Terminal for COM Port
Data Transmission
41
Hyper Terminal for TCP/IP WinSock
Initiate a Hyper Terminal from the Start Menu in Windows (see Figure 4.1), give a
terminal name, choose an icon, and press “OK” button (see Figure 4.2).
(Figure 4.1)
(Figure 4.2)
Select “TCP/IP(Winsock)” option at the “Connect using:” field (see Figure 4.3)
42
.
(Figure 4.3)
After “OK” button is pressed, Figure 4.4 appears. Enter the converter’s IP address
(e.g. 192.168.0.10) at the “Host address:” field, and the Socket port number set for
the Serial Port 1 at the “Port number:” field (e.g 4660). (The Socket type of the
Serial Port 1 should be “TCP Server”.)
(Figure 4.4)
After “OK” button is pressed, Figure 4.5 appears. If the Hyper Terminal connects
with the converter successfully, the time clock at the “left lower” corner “Connected
hh:mm:ss” will start counting.
43
(Figure 4.5)
44
Hyper Terminal for COM Port
Initiate another Hyper Terminal as a COM Port Terminal (in Figure 4.3, select COM
1 or other COM port instead of “TCP/IP (Winsock)”). Set the COM port Properties
to be the same as those set for the Serial Port of the converter.
(Figure 4.3)
Data Transmission
When all steps described above are finished, type any characters on the COM Port
Terminal and check if the typed characters are also displayed on the TCP/IP Winsock
Terminal. Alternatively, check if the characters typed on the TCP/IP Winsock
Terminal are also displayed on the COM Port Terminal. If yes, then all settings are
correct and the converter can operate properly.
45
A
Appppeennddiixx
A
A__??
FAQ
Q. Why can’t the ETM.exe detect the converter on the network?
A. Please check
□□ if the power is properly plugged to the converter.
□□ if the network cable is properly connected between the converter and
the Hub.
□□ If your computer OS is Windows XP version which means
“WINDOWS Firewall” function in OS is activated. However ETM.exe
wouldn’t detect the converter’s IP address, therefore, You have to
temperately disable “WINDOWS Firewall” function. After finishing the
parameters settings, You can restart “WINDOWS Firewall” function.
Refer to the “Hardware Installation” steps in Chapter 3.
Q. Why can’t I use IE to setup the converter?
A. Please check if the network domain of your PC is the same as that of the
converter.
46
A
Appppeennddiixx
B
B
Pin outs and Cable Wiring
DC Power outlet
RJ-45 Pin Assignment
RS-232 Pin Assignment
The pin assignment scheme for a 9-pin male connector on a DTE is given
below.
PIN 1 : DCD PIN 2 : RXD PIN 3 : TXD PIN 4 : DTR
PIN 5 : GND PIN 6 : DSR PIN 7 : RTS PIN 8 : CTS
PIN 9 : DC 5V
47
RS-232 Wiring Diagram
Serial Device EX-9486-W Converter
2 RX 3 TX
3 TX 2 RX
5 GND 5 GND
7 RTS 8 CTS
8 CTS 7 RTS
RS-422 Pin Assignment
The pin assignment scheme for a 4-pin RS-422 is given below.
PIN 1 : R- PIN 2 : R+ PIN 3 : T- PIN 4 : T+
RS-422 Wiring Diagram
Serial Device EX-9486-W TCP/IP Converter
R- 3 T-
R+ 4 T+ T- 1 R­ T+ 2 R+
RS-485 Wiring Diagram
Serial Device EX-9486-W Converter
D- 1 D-
D+ 2 D+
1 2 3 4
(Flow Control)
(Flow Control)
Loading...