Digitool Solutions TAU-252, TAU-1503, TAU-2503, TAU-1002, TAU-502 User Manual

Model Range Square Drive Weight
TAU-252 2.5-25.00 ft-lb 3/8 inch 0.6 pound TAU-502 5-50.00 ft-lb 3/8 inch 0.6 pound TAU-1002 10-100.0 ft-lb 3/8 inch 0.6 pound TAU-1503 10-150.0 ft-lb 1/2 inch 0.8 pound TAU-2503 25-250.0 ft-lb 1/2 inch 0.8 pound
Display: 5-digit, alpha-numeric LCD with function and
battery indicator icons.
Accuracy: Torque: With in ±1% of Indicated Value of both CW
Angle: With in ± 1° when ro tat in g t o 90° at t he speed rate @ 2°/s to 400°/s Required minimum 5% of F.S pre-torque
Resolution:
Units of measure: ft-lb, in-lb, Nm Modes of measure: Torque, Angle Measurement Modes:
ANGLE- Displays applied torque and angle for 15 seconds.
.
TORQUE - Displays torque value in real tim e when torque is loading and shows peak torque when torque is re­ leased.
Visual, Audible Alerts:
Yellow LED and buzzer pulse at 80% - 96% of target torque. Pulse
rate increases as target torque is being approached.
Green LED and buzzer alerts continuousl y when applied torque is within 96% - 104% of target torqu e. Red LED an d buzzer on co ntinuously when applied torque exceeds >104% target torque or wrench full-scale. Tactile Vibration wh en appl ied t orqu e is wit hin ±4% tolerance of the target.
Temperature Drift: ±0.0015%/F Storage Temperature 0ºF to 125ºF Operating Temperature 40ºF to 110ºF Humidity - up to 90% non -condensing
Battery Power:
Uses 3 AAA batteries up to 200 hours of operation
Certification:
This device is calibrated at the factory and is certified to meet International Standards. ISO-6789-2003 and ASME B107-28­2005 standards compliant. Certificate of N.I.S.T. (National Institute of Standards Technology). Traceability from 10% to 100% of full scale.
Maintenance:
To clean the meter, wipe with a lightly dampened cloth. DO NOT use: solvents, thinners or engine cleaners. DO NOT immerse in
any liquids. It is highly recommended that your Torque & Angle Meter be calibrated once a year or every 15,000 cycles; whichever comes first. Contact Digitool Solutions representatives
for repair and calibration services.
Warranty Service and Recalibration
Digitool Solutions provides a 1 year warranty that covers any Digital Torque & Angle Meter which fails to give satisfactory service due to defective workmanship or materials (excluding calibration) for 12 months from the date of original purchase. Calibration is only covered by this warranty for each new unused Torque & Angle Meter out of box. Products must be returned with proof of purchase—freight prepaid—to the warranty service cen­ter listed below.
This warranty excludes Torque & Angle Meters which have been subjected to abnormal use, accidental damage, neglect, or lack of maintenance. Any modification or disassembly of this Torque &
Angle Meter, or repair by an unauthorized service center will void
the warranty. This warranty gives you specific rights. You may also have other rights which vary from state to state. The foregoing obligation is Digitool Solutions sole liability under this or any implied warranty; and under no circumstances shall Digitool Solutions be liable for any incidental or consequential damages. Note: Som e st ates do no t allo w the exclusio n or li mi tation o f incidental or consequential damages so the above limitation or exclusion may not apply to you.
Unit included:
1– TAU-XXXX 2 3 AAA battery 3 Micro USB Cable 4 Driver software communication from TAU-XXX to PC
(DTS_USB.EXE)
5 Blow mold case 6 Users manual
For Warranty Service and Recalibration/Certification
Services, contact:
Digitool Solutions LLC,.
13905 Ramona Ave. Unit #A
Chino, CA 91710
Phone: (909)591-9581
Fax (909) 233-6491
USER’S GUIDE
USB TORQUE & ANGLE
Meter
For Models
TAU-252, TAU-502, TAU-1002,
TAU-1503 , TAU-2503
Accuracy:
Torque. ±1% CW & CCW of 10%-100% of Full scale
Angle. ±1° of 90° rotation @ speed rate 2°/s - 400°/s
Data record:
Up to 360 Data recorded Torque and Angle values
Battery:
Up to 200 hours operation
Display:
5-digit, alpha-numeric LCD with function
and battery indicator icons.
Power off: Auto shut off after 2 minutes idle
Ver. Aug 15
Specifications:
Model Drive ft-lb in-lb Nm
TAU-252 3/8 inch 0.02 ft-lb 0.2 in-lb 0.05 Nm
TAU-502 3/8 inch 0.05 ft-lb 0.5 in-lb 0.1 Nm
TAU-1002 3/8 inch 0.1 ft-lb 0.2 in-lb 0.2 Nm
TAU-1503 1/2 inch 0.2 ft-lb 0.3 in-lb 0.3 Nm
TAU-2503 1/2 inch 0.3 ft-lb 0.6 in-lb 0.6 Nm
Front Panel Display and Keypad
Keypad Functions:
Power ON - M key
U - Unit Select - ft-lb, in-lb or Nm
- Zero Angle (hold the key 3 Sec.)
- Zero Tare Torque (hold the key 3 Sec.)
- Print angle and torque to PC M - Mode Select - TORQUE, ANGLE & PRINT (via USB)
- Manual power off, (hold the key 3 Sec.)
- Increase TARGET TORQUE / ANGLE value
(Push and Hold the key for rapid scrolling) - Decrease TARGET TORQUE value
(Push and Hold the key for rapid scrolling)
Power OFF is automatic after 2 minutes of being idle
Rear Panel Input/Output
1. Setup:
a. P ower ON the Torque & Angle Meter by pushing the M key. Power OFF Push and Ho ld th e M key for m ore than 3 seconds to power down.
b. Push the U key (Select En gi neer ing Uni ts ) Repeatedly push the U key to display the desired Unit of measure, ft-lb, in-lb or Nm.
In Torque Mode:
1– Clear Torque Display ( Push the U key ) 2– Zero tare ( Push and Hold the U key for 3 Sec.)
In Angle Mode: 1– Print torque and angle value to PC (Push the U
when device display PRINT”)
2– Zero Angle ( Push and Hold the U key for 3 Sec.) Make sure the device stays on flat surface and is stationary.
C. Push the M key.( Select To rq ue o r An gl e Mod e. ) 1 - Repeatedly push the M key to select Torque or
Angle Mode.
2 - Exit Print Mode (Hold M key 3 sec.). After each angle measurement, users are presented with PRINT”. To clear the current data and go on to the next angle measurem ent. Hold M key will clear data and setup fo r t he n ew measur emen t.
Continued measurement can be done by applying
torque again.
D. Push the or key. (Increase or Decrease Target Torque to the desired value.) Torque Mode: Use these keys to i ncrease or decrease the Torque Target. Angle Mode: Use th ese keys to i ncrease or decrease to the trigger torque. Trigger torque is the minimum torque required for angle to calculate.
During loading in TORQUE and ANGLE modes, the Torque and Angle Meter will display the applied torque or Angle in real time. The yellow LEDs and The internal buzzer begin pulsing at 80% of the
TARGET TORQUE, increasing as the TARGET
TORQUE value is approached.
2. Application: a. With the power on, install the Torque and Angle Meter
between the driver and the socket.
b. Apply torque load to the fastener in either CW or CCW directions. During loading, the Torque and Angle Meter will display applied torque in real time.
c. When the applied torque is within 4% of the TARGET TORQUE value in PEAK modes, the green LED, buzzer and vibrator (optional) will alert continuously. Stop applying torque, as the installation is complete.
TAU series is The DTS Torque and Angle Meter USB provides Torque accura­cy within ±1% of reading between 10% and 100% of full scale. Angle accuracy ±1° of 90° rotation @ speeds between 2°/s to 400°/s. It is rugged enough to accept the output torque of non­impacting: power tools, nut-runners or robotic spindles. It may be used as an adaptor between any square drive hand tool, such as a ratchet wrench or breaker bar, and common fastener drive sockets
Because the Torque and Angle Meter is entirely self-contained,
there is no wrap up of interconnecting cables during use. The display is user selectable for ft-lb, in-lb or Nm units of measurement.
How to transfer data to PC (via Microsoft Excel, Word, …)
1- After collecting data (Maximum data stored is 360 ) 2- Connect the Micro USB cable to TAU unit 3- Connect the USB to PC 4- Run the program DTS_USB.EXE, which is found on the included CD 5- Make sure the Connection Status Box is Green
If not, Click Check
Comm in the Tool bar 5- Open Microsoft Excel program 6- Move the cursor to any cell to receive the data.. NOTE: Movi ng th e cursor to a different document will cause the data to begin appearing on the new document. 7- Press U on TAU unit to transfer all data to
the PC.
Important Safety Instructions
Introduction
Operator Instructions
WARNING - Risk of flying particles. Read this entire Users Guide before using the
Torque and Angle meter. Always follow good professional tool practices.
Wear Safety goggles.  Ensure that all equipment is in good working order
and that ratings of the Torque Meter, tools and drives exceed the torque being applied.
Never use the Torque and Angle Meter with the
power off.
Never initiate ZeroTare with torque applied. Save these instructions.
Loading...