Digital Watchdog DW-DTMWIPW, DW-DTPIRIPW Quick Start Guide

Quick Start Guide Quick Start Guide
MOTION DETECTORS
DW-DTPIRIPW DW-DTMWIPW
WHAT’S IN THE BOX
1 x detector
1 x mounting temp late
3 x 1.25” (31 .75mm) wall anch ors and washers
2 x spare sliding c urtains
1 x tamper feet 0.039” ( 1mm) long
1 x tamper feet 0.078” (2m m) long.
STEP 1 – Mounting the Motion Detector
1. Find the suitable location to install the SiteWatch™. The sensor should be position so the person will pass across the field of view and not directly toward or away from it.
2. Using the mounting template sheet or the detector itself, mark and drill the necessary holes in the wall. It
is recommended to use the tamper cup on uneven wall surfaces. Refer to Fig. 1.
Suggested mounting hight of 10ft is recommended.
Fig. 1
2. Remove the cover assembly by loosening the locking screw. The cover hinges from the top and lifts out of the
location slot. Refer to Fig. 2.
STEP 2 – CABLING THE DETECTOR
1. Pass the CAT5e/CAT6 cable through the cable entry from outside to inside.
2. Install the Cat5e / Cat6 through the provided hole on the rear of the detector. Terminate the Cat5e / Cat6 cable using an RJ46 connector leaving enough cable to connect to the RJ45 port. Refer to Fig. 3.
3. Plug the connector into the RJ45 port. Refer to Fig. 4.
* Tools are required to crimp RJ45 connector. RJ45 Connector not included.
Use the diagram below to connect your detector to the necessary external devices.
Power input Power consumption
Power over Ethernet (48V DC) Max 3 .8W, PoE class 1
1 x quick setup gui de
NOTE: Download all your support materials and tools in one place.
1. Go to: http://www.digital-watchdog.com/resources.
2. Se arch for your product by entering the part number in the ‘Search by Product’ search bar. Results for applicable part numbers will populate automatically based on the part number you enter.
3. Click ‘Search’. All supported materials, including manuals and quick start guide (QSGs) will appear in the results.
Attention: This document is intended to serve as a quick reference for initial setup. It is recommended that the user read the entire instruction manual for complete and proper installation and usage.
Tel: +1 (866) 446-3595 / (813) 8 88-9555
Technical Support Hours: 9:00AM – 8:00 PM EST, Monday thru Friday
digital-watchdog.com
Locking screw
Fig. 2
NOTE: The maximum mounting height is 10ft when
utilizing the creep detection zone.
Fig. 3
Program
RJ45
Reset
Fig. 4
Quick Start Guide
STEP 3 – INSTALLING THE DETECTOR
1. Nylon washers provided must be used with screws.
2. Ensure cable entry and screw holes are sealed with water-based sealant.
*NOTE: Do not use silicone-based sealant.
Tamper Cup
3. Screw the unit to the wall ensuring that the rear tamper pin is correctly located and that the tamper micro
switch is closed.
4. To aid installation, two spare tamper feet are provided. One is 0.04” (1mm) longer and the other is 0.08” (2mm) longer than the tamper foot originally fitted. The tamper foot is a push fit and can be removed by carefully
pulling it from the pin.
5. When the detector is aligned, connected, and programmed to suit the installation, close the front cover and lock as shown.
STEP 4 – PROGRAMMING THE DETECTOR
The DW-DTPIRIPW and DW-DTMWIPW can be setup remotely via the detector’s web interface. To open the detector’s web interface:
1. Open a web browser.
2. Enter the detector’s default IP address in the in the address bar. The detector’s default IP address is 192.168.0.10.
3. If this is the first time you are accessing your detector’s web interface, you will be prompted to setup the username and password. Follow the guidelines at the bottom of the page to create an adequate password.
NOTE: Default IP address: 192.168.1.10
*
NOTE: Please see the full product manual for web
viewer setup, functions and camera
settings options.
Factory resetting the detector:
1. Make sure the detector is powered on.
2. Hold down the reset button for 8 seconds.
3. Release reset button, the status LED on the board will turn o for a second.
4. The units IP address and login details are now reset back to factory values.