Digital Monitoring Products XR2500F User Manual

Fire Command Center
User’s Guide
XR2500F
Copyright© 2000 - 2005 Digital Monitoring Products, Inc.
Information furnished by DMP is believed to be accurate and reliable.
This information is subject to change without notice.
While the re alarm horns, strobes, or sirens are sounding use one of the following methods to silence the alarm.
1. Turn the keyswitch to enable the four function keys. Then press the SILENCE key. OR
2. Enter your user code. Then press COMMAND.
Note: You may silence an alarm using both of the above methods on the Remote Fire Command Center as well.
XR2500F User’s Guide i
Security Command User’s Guide
for XR2500F Command Processor™ Panels
Table of Contents
Section Page Section Page
Silencing an Alarm......................... Inside Front Cover
Table of Contents ....................................................... i
Emergency Evacuation Plans ................................... iii
Draw a oorplan of your home or business .......................iii
Develop escape routes.....................................................iii
Decide where to meet .....................................................iii
Practice your escape plans...............................................iii
Early detection................................................................iii
Introduction .............................................................. 1
About Your Addressable Fire Alarm Control Panel............... 1
Fire Command Center ..................................................... 1
User Menu ...................................................................... 1
The Fire Command Center .............................................. 2
Using the Keypad ............................................................ 3
Four Function Keys.......................................................... 4
Remote Fire Command Center ......................................... 5
Special Fire Command Center Displays.............................. 5
Special Fire Command Center Tones ................................. 6
Fire Command Center User Menu ..................................... 7
Alarm Silence.................................................................. 8
Sensor Reset................................................................... 8
Outputs On Off .............................................................. 9
Zone Status .................................................................. 10
System Status............................................................... 11
System Test .................................................................. 11
User Proles ................................................................. 12
User Proles Reference.................................................. 13
User Codes ................................................................... 14
Setting the Date and Time ............................................. 16
Ambush Codes .............................................................. 17
Display Events .............................................................. 17
Service Request ............................................................ 17
Fire Drill ....................................................................... 17
Appendix A .............................................................. 18
About the Display Events Section ................................... 18
Zone Event Displays ...................................................... 19
User Code Change Event Displays .................................. 19
Supervisory Event Displays ............................................ 20
System Monitor Event Displays....................................... 20
ii XR2500F User’s Guide
XR2500F Users Guide iii
Section ................................................................ Page
Appendix B .............................................................. 21
Zone Status Browser ..................................................... 21
Outputs On/Off Browser ................................................ 22
Output Groups Browser ................................................. 22
Change User Proles Browser......................................... 23
Add User Codes Browser................................................ 23
Delete User Codes Browser ............................................ 24
Change User Codes Browser .......................................... 24
Entering User Names..................................................... 25
Appendix C .............................................................. 26
Common Keypad Displays.............................................. 26
XR2500F User’s Guide iii
The National Fire Protection Association recommends that you establish an emergency evacuation plan to safeguard lives in the event of a re or other emergency.
Draw a oorplan of your home or business
On a sheet of paper, draw the walls, windows, doors, and stairs. Also draw any obstacles, such as large furniture or appliances, a person may encounter while exiting the building.
Develop escape routes
Determine at least two routes the occupants in each room can take to safely escape. One route can be the most obvious such as the door. Another can be through a window that can be easily opened. If the window is high off the ground, an escape ladder should be provided. Draw arrows on the oorplan to show escape routes from each room.
Decide where to meet
Prearrange a meeting place outside and away from where emergency personnel are likely to be working. A neighbor’s house or across the street in the front of the house are good locations. Always perform a head count to make sure all occupants safely exited. NEVER ENTER A BURNING BUILDING. If the head count shows one or more persons missing, give this information immediately to the authorities. Never enter a building to look for someone.
Practice your escape plans
Devising an escape plan is only the beginning, before the plan can be effective everyone should practice the escape routes from each room.
Second Floor
Building Front
Building Back
First Floor
Fire Escape
Window Ladder
Early detection
The best way to survive a re or other emergency is to get out early. The installation of a re alarm system, with smoke and carbon monoxide detectors in each room, can greatly decrease your risk of loss or injury.
Emergency Evacuation Plans
iv XR2500F User’s Guide
This page intentionally left blank
Introduction XR2500F User’s Guide 1
Introduction
A Remote Fire Command Center is also available to use with the XR2500F Addressable Fire Alarm Control Panel. The remote keyboard can be placed anywhere throughout the premises.
Both keyboards have four additional function keys, to be used for alarm silencing, resetting smoke detectors, system testing, and performing re drills. Both keyboards require the user to turn a keyswitch to enable the four function keys.
User Menu
The keyboards also provide access to the User Menu, which contains all of the functions necessary to fully operate your system.
Note: Because the XR2500F is based upon the XR500N Command Processor, some prompts provided on the User Menu are not necessary for XR2500F operation. If the User Menu provides you with an option not discussed in this User Guide, please disregard it and press the COMMAND key to move on to the next prompt.
The following menu items are not used with the XR2500F:
• Door Access
• Armed Areas
• Bypass Zones
• Zone Monitor
• Schedules
About Your Addressable Fire Alarm Control Panel
The Addressable Fire Alarm Control Panel is designed with your safety and comfort in mind. It uses the latest in computer based technology to create the most advanced and user-friendly re, security, and access control system available.
The Addressable Fire Alarm Control Panel combines ease-of-use with a simple-to-understand Fire Command Center display to offer the full range of features requested by today’s re system owners.
You can turn portions of your protection on or off at any time by pressing a few keys. You can add, delete, and change personal user codes at any time or check the status of protection devices in the system. An added feature of the Addressable Fire Alarm Control Panel is the membrane keyboard with four additional function keys you may use to easily perform a variety of functions.
Fire Command Center
The XR2500F comes with a built-in LCD display with a 20-key membrane keyboard called the Fire Command Center. The keyboard is mounted behind an opening in the red enclosure door. Use the keyboard to perform a variety of functions as listed in this User’s Guide.
2 XR2500F User’s Guide Introduction
Introduction XR2500F Users Guide 3
The Fire Command Center
Your system comes equipped with a built-in, easy-to-use Fire Command Center that allows you to properly operate the system. The keyswitch to the left of the keyboard must be turned to the “enable” position before you can use the four functions keys. It is not necessary to use the keyswitch when using a user code to perform operations. The illustration and descriptions below highlight some features of the Fire Command Center:





   
 
 












The S elect keys
There are four keys under the display called the Select keys. They allow you to choose what to do by pressing the Select key under choices being shown in the display.
Data Entry keys
These keys allow you to enter your user code and other information into the system.
The B ack A rrow key
Use the Back Arrow key to go back through displays while operating your system. Press the Back Arrow key to back up through the list of User Menu functions or to make a correction by erasing the last character you entered.
The C OMMAN D key
The COMMAND key allows you to advance through the displays or User Menu or complete a data entry function.
Statu s LED s
The Fire Command Center incorporates three LEDs to indicate the system status. The three indicator lights are described below.
POWER LED
This LED remains ON steady when both AC and battery input are good. The LED turns OFF when AC input is low. The LED ashes at half-second intervals when battery input is low.
TRO UBL E L ED
This LED turns ON when any trouble displays in the status list, such as AC, battery, phone line, transmit, ground fault, NAC, or any zone trouble. This light is OFF when no trouble displays in the status list.
ALARM LED
The ALARM LED is ON when any alarm currently displays in the status list. This LED is OFF when no alarm currently displays in the status list.
Introduction XR2500F User’s Guide 3
Note: If areas are not pre-programmed at installation to display at this keypad, they cannot be viewed.
Aster isks in Ar ea Ar med D isp lays
Asterisks display next to a programming option that is already selected. As shown in the example, options chosen to display the current programming selection have an asterisk next to the number. Those that are not selected simply display the number. In the Devices example, keypads 3, 8, 9, and 15 are not selected. In the example, Areas 3, 8, 9, 15, 19, 23, 25, and 31 are not selected. In both examples the numbers with asterisks are selected.
*1 *2 3 *4 *5 *6 *7 8 *13 *14 15 *16
9 *10 *11 *12
Devices
*29 *30 31 *32
*13 *14 15 *16
9 *10 *11 *12
25 *26 *27 *28
*1 *2 3 *4 *5 *6 *7 8 *21 *22 23 *24
*17 *18 19 *20
Areas
To select or deselect a number, simply enter the number using the digit keys on the keypad. This same scheme is used when viewing the panel armed status and other programming and operational functions. Remember to press the COMMAND key to display the rest of the device or area numbers.
Using the Keypad
Multi -ling ual D ispla y O ption
Your system may be programmed to display the User Menu and Status Display text in multiple languages. When the COMMAND key is pressed, the option to choose the language displays. Press the top row Select key under the language you want to use. The language chosen continues to display at this keypad until another language is chosen. If this is not programmed, the option to select a language does not display.
Keypa d Dis plays Curr ent Prog rammi ng
Most User Menu options displayed at the keypad show the currently selected option in the panel memory. These options are either shown as a number, a blank, or a NO or YES. To change a number press any top row Select key. The current option is replaced with a dash. Press the number(s) on the keypad you want to enter as the new number for that option.
It is not necessary to enter numbers with leading zeros. The panel automatically right justies when you press the COMMAND key.
To change an option that requires a NO or YES response, press the top row Select key under the response not selected.
For example, if the current option is YES and you want to change it to NO, press the third top row Select key. The display changes to NO. Press the COMMAND key to go to the next option.
Multi ple D ispla ys Co nta ining Prog rammi ng
For many User Menu options, such as Access Areas, there are several displays containing lists. For example, in Access Areas, areas 1 through 32 display on four separate displays. First, areas 1 through 8 display. Press the COMMAND key to display areas 9 through 16. Press the COMMAND key again to display areas 17 through 25. Press the COMMAND key one more time to display areas 26 through 32.
4 XR2500F User’s Guide Introduction
Introduction XR2500F Users Guide 5
User Options
The User Options allow you to make adjustments to your keypad to best t your environment and needs.
To access the User Options portion of the keypad, press and hold the Back Arrow and COMMAND keys for two seconds. The keypad display changes to SET BRIGHTNESS. Press the COMMAND key to display the next option or the Back Arrow key to exit.
Backl ighti ng Br ightn ess
Sets the keypad LCD, AC LED, and the Green keyboard backlighting brightness level. At the SET BRIGHTNESS display, use the left Select key to lower the keypad brightness. Use the right Select key to increase the brightness.
Note: If the brightness level is lowered, it temporarily reverts back to maximum intensity whenever a key is pressed.
Inter nal S peake r Ton e
Sets the keypad internal speaker tone. At the SET TONE display, use the top left Select key to make the tone lower. Use the right Select key to make the tone higher.
Volum e lev el
Sets the keypad internal speaker volume level for key presses and prewarn conditions. During alarm, trouble, and prewarn conditions, the volume is always at maximum level. At SET VOLUME LEVEL, use the left Select key to lower the keypad volume. Use the right Select key to raise the volume.
Model Numb er
The keypad model number, rmware version, and date display, but cannot be changed.
Four Function Keys
The Fire Command Center is designed with four additional keys on the left side of the keypad. After turning the keyswitch, you can quickly perform vital functions using these four keys.
SILEN CE Ke y
Pressing the SILENCE key silences the alarm bells.
RESET Key
Pressing the RESET key performs a sensor reset and silence the alarm bells.
TEST Key
Pressing the TEST key performs a system test.
DRILL Key
Pressing the DRILL key displays a prompt “SURE? YES NO”. Press YES to begin the re drill. Press NO to return to the status list.
Introduction XR2500F User’s Guide 5
Remote Fire Command Center
You can expand the XR2500F Addressable Fire Alarm Control Panel by adding a Remote Fire Command Center. With the Remote Fire Command Center, users can access the User Menu and perform the same functions as the Fire Command Center in the panel enclosure. All of the keys, except the four function keys, can be used at any time without turning the keyswitch.
You can only use the four function keys when the keyswitch is turned to the enable position. These keys are the same as those on the Fire Command Center in the panel. Both keyboards also have the same displays and prompts. Follow the same instructions for using both keyboards.
Below is an illustration of the Remote Fire Command Center showing the keyswitch lock that enables the four function keys.





   
 
 












Special Fire Command Center Displays
As you use your system, you occasionally see a display that asks you to enter a code or that describes a condition on the system. Below are some examples of the displays:
ALARM
A 24-hour zone (for example re or panic) or an armed burglary zone has been tripped. Your system may sound bells or sirens.
ALARM NOT SENT
The alarm signal was not sent to the central station because a user code was entered to disarm the system before the alarm signal was sent to the centralstation.
ALARM CANC ELLED
An Alarm Cancel signal was sent to the central station because a user code was entered after an alarm was sent to the central station.
TROUB LE
There is a problem with a protection device or system component. This display is accompanied by a description of the problem.
ENTER CODE
The system requires you to enter your user code. User codes can be required for turning your system on (arming), turning your system off (disarming), and many other functions.
As you enter your user code, the keypad display shows an asterisk (*) in place of each digit pressed. This keeps others from seeing your user code on the display as it is entered.
TRY A GAIN or IN VALID CO DE
The user code you have entered is not recognized by the system. Check the user code and try again.
Loading...