![](/html/5f/5f67/5f67f84e09b8e18244ae68a3ff68fcc9f36693bbd717a5204ad7f85b2294b699/bg1.png)
1154 WIRELESS FOUR-ZONE INPUT MODULE
Installation Guide
PROGRAM THE PANEL
The 1154 can be programmed with up to four zones. When
programming the 1154 in the panel, refer to the panel
programming guide as needed.
1. In ZONE INFORMATION, enter the ZONE number, and
then press CMD.
2. Enter the ZONE NAME and press CMD.
3. Once ZONE TYPE appears, select the appropriate
zone type, and then press CMD.
4. At the NEXT ZONE prompt, select NO. If you see the
WIRELESS ZONE prompt, select YES.
Note: If you are programming the 1154 onto a
zone that can be either hardwired or wireless,
then this prompt appears. If the zone you are
programming is wireless-only, then the prompt
does not appear.
5. Enter the eight-digit SERIAL NUMBER and press CMD.
6. Enter the CONTACT number being used.
7. Enter the SUPERVSN TIME and press CMD.
8. At the NEXT ZONE prompt, select YES and continue
to program up to three more zones.
Note: Zones must be entered sequentially. For
example, if you begin by programming zone 71,
you would need to program zone 72 as the next
contact.
MOUNT THE 1154
The 1154 Wireless Input Module should be placed close to
the existing non-DMP panel.
With the 1154's housing cover removed, use the supplied
screws to secure the 1154 to a wall or other flat surface. The
1154 PCB has built-in holes to allow you to screw the housing
onto a surface without removing the PCB. See Figure 2.
Figure 1: 1154 Housing
DESCRIPTION
The 1154 Wireless Four-Zone Input
Module is designed to convert up
to four existing normally closed,
hardwired zones (such as motion
sensors, door & window contacts,
etc.) into wireless zones.
When a DMP panel is installed in
a location with an existing non-
DMP panel, then the 1154 can be
connected to the existing panel's
12 Volt auxillary power. Once
connected, the 1154 Wireless Input
Module converts up to four existing
hardwired zones into wireless zones.
This allows the new DMP panel to
communicate with the existing zones.
1
2
Compatibility
All DMP 1100 Series Wireless
Receivers and burglary
panels. See the last page for
compatibility details.
What is Included?
• 1154 Wireless Four-Zone Input Module
• 3V Lithium CR123A battery
• Hardware pack
Optional items:
• Model 376L DC Power Supply
• Model 505-12 12VDC Power Supply
Power Source
Selector Pins
Input Power
Terminal Block
EXT BAT
+
-
Figure 2: 1154 Wireless Input Module PCB
+
3V
Lithium
Battery
—
Zone Wiring
Terminals
LT-1619 © 2017 Digital Monitoring Products, Inc.
Mounting Holes
17351
![](/html/5f/5f67/5f67f84e09b8e18244ae68a3ff68fcc9f36693bbd717a5204ad7f85b2294b699/bg2.png)
+
—
3V
Lithium
Battery
+
_
3
4
WIRE THE 1154 ZONES
Wire the zones and connect the receiver before installing the battery or connecting a power
supply to the 1154.
1. Locate the existing contacts that you want to connect to the 1154. These contacts should be
within 100 feet of the 1154.
2. Use 18–22 gauge wire to connect a zone device to terminals Z1+ and Z1-.
3. Repeat Step 2 for the remaining zones, as needed.
Note: When wiring normally closed contacts, EOL resistors do not need to be changed or
removed.
POWER THE 1154
The 1154 Wireless Input Module can be powered several ways:
• Existing Panel or Plug-In Power Supply
If connecting the 1154 to powered zones, such as PIRs or glass-break detectors, power the
1154 through the existing panel (12VDC with ground) or the plug-in power supply (model
376L). See Option A or Option B.
Note: Powered zone devices must be connected to the existing panel (or another power
supply) for power.
• 12VDC Power Supply
If you want to completely remove the existing non-DMP panel, but you are connecting the
1154 to powered zones such as PIRs or glass-break detectors, power the 1154 and powered
zone devices from a DMP Model 505-12 power supply. See Option C.
• Battery Power
If connecting the 1154 to non-powered zones, such as door or window contacts, or batterypowered contacts, the 1154 can be powered by a single CR123A 3V battery. See Option D.
Caution: Do not connect the 1154 to an external power supply (existing panel, plug-in
power supply, 505-12, etc.) if there is a CR-123A 3V battery installed in the module.
Option A: Power from an Existing Panel
If the 1154 is powered from an existing panel, the existing panel must be connected to AC power.
Powered zones connected to the 1154 may need to be connected to the existing panel for power.
1. Place the jumper on the two power source selector pins labeled EXT to enable external
power supply operation.
2. Using 18–22 gauge wire, connect a black wire to the ground terminal on the existing panel,
and a red wire to a terminal on the panel with 12VDC power. See Figure 3.
3. Connect the black wire to the negative terminal on the 1154's input power terminal block,
and the red wire to the positive terminal.
4. Snap the 1154 housing cover into place.
Existing
Panel
GND
18–22
Gauge
Wire
Figure 3: Powering the 1154 Wireless Input Module from
an Existing Panel with Wired, Non-Powered Zones
GND
AC
Power
Supply
Back-Up
Battery
Power Source
Selector Pins
Input
Power
Terminal
Block
Non-
Powered
Zone
Device 1
Non-
Powered
Zone
Device 2
Zone Wiring
Terminals
Non-
Powered
Zone
Device 3
Non-
Powered
Zone
Device 4
2 1154 INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS