The 1154 can be programmed with up to four zones. When
programming the 1154 in the panel, refer to the panel
programming guide as needed.
1. In ZONE INFORMATION, enter the ZONE number, and
then press CMD.
2. Enter the ZONE NAME and press CMD.
3. Once ZONE TYPE appears, select the appropriate
zone type, and then press CMD.
4. At the NEXT ZONE prompt, select NO. If you see the
WIRELESS ZONE prompt, select YES.
Note: If you are programming the 1154 onto a
zone that can be either hardwired or wireless,
then this prompt appears. If the zone you are
programming is wireless-only, then the prompt
does not appear.
5. Enter the eight-digit SERIAL NUMBER and press CMD.
6. Enter the CONTACT number being used.
7. Enter the SUPERVSN TIME and press CMD.
8. At the NEXT ZONE prompt, select YES and continue
to program up to three more zones.
Note: Zones must be entered sequentially. For
example, if you begin by programming zone 71,
you would need to program zone 72 as the next
contact.
MOUNT THE 1154
The 1154 Wireless Input Module should be placed close to
the existing non-DMP panel.
With the 1154's housing cover removed, use the supplied
screws to secure the 1154 to a wall or other flat surface. The
1154 PCB has built-in holes to allow you to screw the housing
onto a surface without removing the PCB. See Figure 2.
Figure 1: 1154 Housing
DESCRIPTION
The 1154 Wireless Four-Zone Input
Module is designed to convert up
to four existing normally closed,
hardwired zones (such as motion
sensors, door & window contacts,
Wire the zones and connect the receiver before installing the battery or connecting a power
supply to the 1154.
1. Locate the existing contacts that you want to connect to the 1154. These contacts should be
within 100 feet of the 1154.
2. Use 18–22 gauge wire to connect a zone device to terminals Z1+ and Z1-.
3. Repeat Step 2 for the remaining zones, as needed.
Note: When wiring normally closed contacts, EOL resistors do not need to be changed or
removed.
POWER THE 1154
The 1154 Wireless Input Module can be powered several ways:
• Existing Panel or Plug-In Power Supply
If connecting the 1154 to powered zones, such as PIRs or glass-break detectors, power the
1154 through the existing panel (12VDC with ground) or the plug-in power supply (model
376L). See Option A or Option B.
Note: Powered zone devices must be connected to the existing panel (or another power
supply) for power.
• 12VDC Power Supply
If you want to completely remove the existing non-DMP panel, but you are connecting the
1154 to powered zones such as PIRs or glass-break detectors, power the 1154 and powered
zone devices from a DMP Model 505-12 power supply. See Option C.
• Battery Power
If connecting the 1154 to non-powered zones, such as door or window contacts, or batterypowered contacts, the 1154 can be powered by a single CR123A 3V battery. See Option D.
Caution: Do not connect the 1154 to an external power supply (existing panel, plug-in
power supply, 505-12, etc.) if there is a CR-123A 3V battery installed in the module.
Option A: Power from an Existing Panel
If the 1154 is powered from an existing panel, the existing panel must be connected to AC power.
Powered zones connected to the 1154 may need to be connected to the existing panel for power.
1. Place the jumper on the two power source selector pins labeled EXT to enable external
power supply operation.
2. Using 18–22 gauge wire, connect a black wire to the ground terminal on the existing panel,
and a red wire to a terminal on the panel with 12VDC power. See Figure 3.
3. Connect the black wire to the negative terminal on the 1154's input power terminal block,
and the red wire to the positive terminal.
4. Snap the 1154 housing cover into place.
Existing
Panel
GND
18–22
Gauge
Wire
Figure 3: Powering the 1154 Wireless Input Module from
an Existing Panel with Wired, Non-Powered Zones
GND
AC
Power
Supply
Back-Up
Battery
Power Source
Selector Pins
Input
Power
Terminal
Block
Non-
Powered
Zone
Device 1
Non-
Powered
Zone
Device 2
Zone Wiring
Terminals
Non-
Powered
Zone
Device 3
Non-
Powered
Zone
Device 4
2 1154 INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS
Page 3
Option B: External DC Plug-In Power Supply
- +
- +
When using the optional Model 376L plug-in DC power
supply, mount the 1154 near a wall outlet or other power
source.
1. Place the supplied jumper on the two power source
selector pins labeled EXT to enable external power
supply operation.
2. Connect the wiring from the power supply to the input
power terminal block. Connect the black wire to the
negative terminal and the black and white wire to the
positive terminal. See Figure 4.
3. Plug the Model 376L power supply into a 110VAC outlet.
4. Snap the 1154 housing cover into place.
Option C: External 12VDC Power Supply
Use 18–22 gauge wire to connect the 1154 to an external
12VDC power supply with battery backup, such as the DMP
Model 505-12.
1. Place the supplied jumper on the two power source
selector pins labeled EXT to enable external power
supply operation.
2. Observing the polarity of all wired connections, use
18–22 gauge wire to connect the 1154's input power
terminal block to the +DC - terminal on the 505-12
power supply. See Figure 5
3. Snap the 1154 housing cover into place.
Black &
White Wire
Figure 4: 1154 DC Terminals and
505-12 Power
Input Power
Terminal Block
Black
Wire
Model 376 L
DC Plug-In
Power
Supply
Plug-In Power Supply
18–22
Gauge
Wire
Supply
1154 PCB
& Housing
1154 Input Power
Terminal Block
- +
+ DC -
Option D: Battery Power
Remember to observe polarity when installing a battery into
the 1154 Input Module. Only use a 3V Lithium battery, such
as DMP Model CR123. Battery life expectancy for the 1154 is
three years.
1. If needed, remove the old battery and properly dispose
of it.
2. Place the supplied jumper on the two power source
selector pins labeled BAT to enable battery operation.
3. Place a new battery into the holder and press it into
place. See Figure 2.
4. Snap the 1154 housing cover into place.
Caution: Properly dispose of used batteries. Do not
recharge, disassemble, heat above 212°F (100°C), or
incinerate.
+ BAT —
Back-Up
Battery
Figure 5: 1154 DC Connection to
External Power Supply with
Battery Backup
1154 INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS 3
Page 4
FCC INFORMATION
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. this device must accept any interference received, including interference that may cause undesired operation.
The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm (7.874 in.) from all persons. It
must not be located or operated in conjunction with any other antenna or transmitter.
Changes or modifications made by the user and not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Industry Canada Information
This device complies with Industry Canada Licence-exempt RSS standard(s). Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes:
1. l’appareil ne doit pas produire de brouillage, et
2. l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
This system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits specified by Health Canada Safety
Code 6. The system must be installed at a minimum separation distance from the antenna to a general bystander of 7.87 inches (20 cm)
to maintain compliance with the General Population limits.
L’exposition aux radiofréquences de ce système a été évaluée selon la norme RSS-102 et est jugée conforme aux limites établies par le
Code de sécurité 6 de Santé Canada. Le système doit être installé à une distance minimale de 7.87 pouces (20 cm) séparant l’antenne
d’une personne présente en conformité avec les limites permises d’exposition du grand public.
1154 Wireless Four-Zone
Input Module
Compatibility
Specifications
Battery
Life Expectancy 3 years
Type 3V Lithium CR123A
Frequency Range 905-924 MHz
Dimensions 4.65”L x 3.1”W x 1.4”H
Color White
Housing Material Flame retardant ABS
Accessories
CR123 DMP 3V Lithium Battery
376L DC Plug-in Power Supply
505-12 12VDC Power Supply
XT30 panels with 1100D Series Wireless Receiver
XT50 panels with integrated wireless receiver or 1100D Series Wireless
Receiver
XR150/XR550 Series panels with 1100X Series Wireless Receivers
XTLplus panels with integrated wireless receiver
XTLC panels with integrated wireless receiver
1100D/1100X Series Wireless Receiver Version 105 or higher
Patents
U. S. Patent No. 7,239,236
Certifications
FCC Part 15 Registration ID CCKPC0101
IC Registration ID 5251A-PC0101
Designed, engineered,
and manufactured in
Springfield, Missouri
INTRUSION • FIRE • ACCESS • NETWORKS
2500 North Partnership Boulevard
Springfield, Missouri 65803-8877
800-641-4282 | dmp.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.