height form factor, with mounting assembly
(first device in removable-media slot)
RRD43–MYEmbedded RRD43 disc drive 5.25-inch
half-height form factor (second device in
removable-media slot)
RRD43–FBTabletop RRD43 disc drive with cable kit
and US power cord
RRD43–DHTabletop RRD43 disc drive with cable kit;
requires country-specific power cord
Field Replacable Units and Options
RRD43 driveRRD43–AA
Test disc30–23507–03
Documentation
RRD43 CD–ROM Drive
EK–RRD43–IN
Installation Guide
DEC 4000 AXP Owner’s Guide
EK–KN430–OP
(VMS Ops)
DEC OSF/1 AXP Factory
EK–SFFIS–UG
Installed Software User Guide
Figure 1 shows the indicators, jumpers, and connectors on the RRD43 disc
drive.
Note
In a DEC 4000 system, the SCSI ID select cable is used instead of
jumpers.
3
Page 4
RRD43
Figure 1 RRD43 Disc Drive Connectors and Indicators
Front
Rear
Busy
Indicator
Light
SCSI
ID
Headphone
Jack
Audio
Out
Frame Ground
Headphone
Volume
Control
SCSI
Connector
Terminator Sockets
RRD43 ID Jumpers 1-4
SCSI ID Jumper Settings
ID
0
1
2
3
4
5
6
7
Parity jumper Out = Mode 0 (MS-DOS and SCO UNIX)
Parity jumper In = Mode 1 (Open VMS and OSF/1)
124
Out
In
Out
In
Out
In
Out
In
Out
Out
In
In
Out
Out
In
In
Out
Out
Out
Out
In
In
In
In
Eject
Button
Pin 1
Manual
Eject
Hole
Power
Connector
GND +5 V +5 V
NC
ID Select
4
2
1
RET
Parity
MLO-012220
4
Page 5
RRD43
Installation
Before you begin the installation procedure, remove the bus continuity card
from the option storage slot into which you intend to install the disc. Figure 6
shows the location of the bus continuity cards.
To install an RRD43-MX disc drive in your system, perform the following steps:
1. Slide the RRD43-MX mounting bracket assembly into the option storage
slot and push until the connector on the SCSI paddle card on the bracket
engages securely into the backplane. Secure the drive in place by
tightening the two captive screws (Figure 2). Do not over-tighten the
screws. It is normal for there to be a slight gap between the bracket and
chassis.
2. Attach the SCSI ID cable to the OCP connector on the bezel assembly
(Figure 2).
3. Insert the tabs on the bottom of the bezel into the slots on the storage slot
(Figure 2).
4. Push in the top of the bezel, and tighten the Phillips screw (Figure 2).
5. Install a SCSI ID plug to the front of the bezel, making sure that the SCSI
ID number is not used by another device.
To add an RRD43-MY disc drive to your system, perform the following steps:
1. Remove the mounting assembly by reversing steps 1 through 5 above.
2. Connect the SCSI ID cable to the back of the drive (Figure 1), making sure
that the jumper is installed over the pins marked PARITY.
3. Slide the drive into the mounting assembly.
4. Attach the SCSI and power cables to the drive. Figure 1 shows the location
of the connectors.
5. Secure the drive into the mounting assembly with the four mounting
screws provided. Two screws attach to the top of the assembly, and two
screws attach to the bottom of the assembly (Figure 3 shows the top of the
assembly). Make sure that the top front screw goes through the grounding
strip shown in the figure.
Failure to connect the grounding strip could result in data errors.
Caution
5
Page 6
RRD43
6. Remove the blank panel from the bezel (Figure 4).
7. Remove the blank flat plug(s) from the bezel (Figure 5).
8. Return the OCP connector board to the bezel.
9. Install SCSI ID plugs on the front of the bezel. Each drive must have an
unique SCSI ID number. If one of the drives was installed prior to this
add-on procedure, make sure that you use the same SCSI ID number that
was used previously. The bezel is marked to show the corresponding SCSI
ID plug to each slot.
10. Slide the mounting bracket assembly into the option storage slot and
push until the SCSI paddle card on the bracket engages securely into the
backplane. Secure the drive in place by tightening the two captive screws
(Figure 2). Do not over-tighten the screws. It is normal for there to be a
slight gap between the bracket and chassis.
11. Attach each SCSI ID cable into the appropriate connector on the OCP
connector board on the bezel (Figure 2). Make sure that the cable from the
RRD43-MX drive is returned to the connector in which it was originally
installed.
12. Insert the tabs on the bottom of the bezel into the slots on the storage slot
(Figure 2).
13. Push in the top of the bezel, and tighten the Phillips screw (Figure 2).
6
Page 7
Figure 2 Installing an RRD43-MX Disc Drive
1
4
Tighten
screw.
RRD43
Tighten
screw.
2
Insert
SCSI ID
connector.
When a removable-media compartment is empty, blank bezels are
required to maintain maximum air flow.
Scale = 21/64
TRUGRA.DQ
Note
3
Insert
bezel.
MLO-012701
7
Page 8
RRD43
Figure 3 Inserting Mounting Screws
Mounting Screws
Grounding Strap
MLO-012703
8
Page 9
Figure 4 Removal of Blank Panel
12
Push Spring Tab
Blank Panel
RRD43
Remove Blank Panel
MLO-010646
9
Page 10
RRD43
Figure 5 Removal of Blank Flat Plugs
FrontRear
1
Unload
Lever
Operate
Tape in Use
Protect
Write
Blank
Flat Plugs
Push Back Two
Spring Tabs
23
Lift Out
Board
Remove Blank
Flat Plugs
Note: Re-install board and then insert standard ID plugs.
10
MLO-010648
Page 11
Figure 6 Bus Continuity Card
Dual Half-Height
SCSI Drives
Continuity Card
Full-Height
SCSI Drives
J6
J7
J4
J5
RRD43
Full-Height
SCSI Drives
J2
J3
Dual Half-Height
SCSI Drives
Full-Height
SCSI Drives
When either the J6 or J7 backplane connector is not used, insert a bus
continuity card into those slots to maintain bus continuity. There are
two bus continuity cards already installed in the backplane.
Full-Height
SCSI Drives
MLO-009431
Note
11
Page 12
RRD43
Figure 7 Inserting an RRD43 Disc
2
Insert disc.
(hold disc
by side edge)
1
Press eject
button.
3
Push disc
tray in.
12